MULTITASKER™
400-0367-004
12
Command Format: [OFFCnUi]
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
There is an
MT107-103
in slot 5. Turn off all
outputs by sending the command
[OFFC5].
11.
[ImmOxxCn]
This command connects a single input to a
single output in the current matrix configuration.
Command Format: [ImmOxxCnUi]
mm = Input (2 digit # from 01 to 64)
xx = Output (2 digit # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Connect Input 22 to Output 32 of the engine in
slot 5. Send the command [I22O32C5] and
Input 22 will be connected to Output 32.
12.
[ImmO*Cn]
This command connects a single input to all the
outputs in the current matrix configuration.
Command Format: [ImmO*CnUi]
mm = Input (2 digit # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example:
Connect Input 07 of the engine in slot 5 to all
the outputs for that engine in its current matrix
configuration. To do this, send the command
[I07O*C5].
13.
[INmmSCn]
This command returns all the output numbers
that are connected to an input and enabled.
Command Format: [INmmSCnUi]
mm = Input Number (mm = # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example 1:
There is an
MT107-103
in slot 5. Input 1 is
connected to Output 1. Send the command
[IN01SC5] and receive the following feedback:
[1C05]
Example 2:
There is an
MT107-103
in slot 5. Input 1 is
connected to all outputs and all outputs are
enabled. Send the command [IN01SC5] and
receive the following feedback:
[1,2,3,4,5,6,7,8,9,10,11,12,13…,64C05]
Example 3:
There is an
MT107-103
in slot 5. Input 1 is
connected to all outputs, but only outputs 1-10
are enabled. Send the command [IN01SC5] and
receive the following feedback:
[1,2,3,4,5,6,7,8,9,10C05]
14.
[OUTmmSCn]
This command returns the input number that is
connected to an output if the output is enabled.
Command Format: [OUTmmSCnUi]
mm = Output Number (mm = # from 01 to 64)
Cn = Card ID (n = slot # from 1 to max slots)
Ui
= Unit ID (i = # from 0 to 9)
Example 1:
There is an
MT107-103
in slot 5. Input 1 is
connected to all outputs. Send the command
[OUT01SC5] and receive the following
feedback:
[1C05]
Example 2:
There is an
MT107-103
in slot 5. Input 64 is
connected to Output 64, but Output 64 is
disabled. Send the command [OUT64SC5] and
receive the following feedback:
[0C05]