Torque Settings*
G1/2" BSPP male
(flush)**
G1" BSPP male
(semi-flush)
Thread Type
All Pressures
Max. 50 Nm
For more information please contact
info
@
althen.de
* The torque values apply only to test conditions and are a guide only. Tightening torques for
installation depend on many factors, including materials, lubrication, coating and surface treatment. If
in doubt the manufacturer is to be consulted.
** It is recommended that the PR3850 is used in conjunction with weld socket part No. 8016 for best
results. Alternatively customer may machine an appropriate mating connection in their equipment to
replicate the dimensions detailed in part 8016 (detailed diagrams available on request).
Materials for mating part should be selected to suit pressure and media requirements.
10
Protran® PR3850
User Manual
Tightening Torques