Table of Contents
CAUTIONS AND WARNINGS: RISK OF FIRE, INJURY OR DEATH
......................................................1
Explanation of Wood & Biomass Combustion...............................................................................................2
Wood Moisture Content & Wood Gasification..............................................................................................2
Mode of Operation.........................................................................................................................................3
Rigging and Positioning of Boiler..................................................................................................................7
Clearances to Combustibles Required for Safety and Operation...................................................................7
Installation and maintenance of Electrical Controls and Gauges..................................................................8
Installation of Smoke Detectors and CO Monitors........................................................................................8
Installation of Smoke Hood Option................................................................................................................8
Installation of Bottom Insulation....................................................................................................................9
Specific Chimney Requirements for the Wood Gun™..............................................................................9
Technical Aspects of Chimney Performance.............................................................................................9
Draft.........................................................................................................................................................10
Barometric Damper.................................................................................................................................10
Manometer...............................................................................................................................................10
Masonry Chimneys..................................................................................................................................11
Prefabricated Chimneys...........................................................................................................................11
Stovepipe Specifics for SE210................................................................................................................14
Wall Pass-Through: United States...........................................................................................................14
Wall Pass-Through: Canada.....................................................................................................................15
Common Chimney Problems.......................................................................................................................15
In case of chimney fire.................................................................................................................................16
In Case of Runaway Fire..............................................................................................................................16
In Case of Power Loss..................................................................................................................................16
Make-up or Combustion Air.........................................................................................................................17
Piping the Boiler in Parallel with Another Boiler....................................................................................18
Pressure Relief Valve...............................................................................................................................18
Pressure Reducing Fill Valve...................................................................................................................18
Expansion Tank Selection........................................................................................................................19
Return water temperature.............................................................................................................................19
Additional Specifications.............................................................................................................................20
Low Water Cutoff Testing........................................................................................................................20
Low Water Cutoff Troubleshooting.........................................................................................................20
Low Water Cutoff Maintenance...............................................................................................................21
Содержание WOOD GUN Super E210
Страница 2: ......
Страница 57: ...Appendix B Wiring Diagrams 51 ...
Страница 58: ...Appendix C Exploded Parts Drawings 52 ...
Страница 59: ... 53 ...
Страница 60: ... 54 ...
Страница 66: ...Appendix F Boiler Piping and Ducting Examples 60 ...
Страница 67: ...Wood Gun Air Inlet Ducting Installations 61 ...
Страница 70: ...APPENDIX G Markings 64 ...
Страница 71: ...Datalabel 65 ...