An individual burn cycl , using high quality fu l
that is tightly pack d into th Wood Gun SE210 CS
fier box, can produc as much as a million BTUs. As a
practical matta r, to accommodat a full load of wood,
you should b pr par d to stor 800,000 BTUs. If in
consulting th charts that follow, you choos to
provid l ss storag , you should plan on a fiering
patta rn and fu l load amounts that m t th
obj ctiv of avoiding mid-burn off cycl s, v n if this
m ans partial loads of fu l. In th chart b low,
T º F
r pr s nts th t mp ratur spr ad b tw n high and
low t mp ratur s in th rmal storag .
BTUs Stored Based on Gallons and
T º F
Gallons
T º F
500
1000
1500
20º
80,000
160,000
240,000
40º
160,000
320,000
480,000
60º
240,000
480,000
720,000
80º
320,000
640,000
960,000
The chart that follows giv s you th numb r of
hours until th n xt fiering cycl , bas d on a starting
t mp ratur for th rmal storag of 190º F.
Lowest
Usable
Water Temp
Heat Load
in BTU/hr
110º F
130º F
150º F
15,000
44.7
34.0
23.3
25,000
27.6
21.2
14.8
35,000
20.3
15.7
11.1
45,000
16.2
12.6
9.1
65,000
11.8
9.4
7.2
100,000
8.4
6.8
6.4
150,000
6.3
5.2
5.0
CONDITIONING OF BOILER WATER
Prop r tr atm nt of f d wat r and boil r wat r is
n c ssary to pr v nt d posits and corrosion within
th boil r. The n gl ct of ad quat xt rnal and
int rnal tr atm nts can l ad to op ration faults or
total boil r failur . Wh r a choic is availabl , pr -
tr atm nt xt rnal to th boil r is always pr f rr d
and mor r liabl than tr atm nt within th boil r.
Instructions for f d wat r tr atm nt as pr par d
by a comp t nt f d wat r ch mist should b
follow d. Do not xp rim nt with hom mad
tr atm nt m thods or compounds.
R pr s ntativ sampl s of f d wat r and boil r
wat r n d to b analyz d fr qu ntly to nsur that
th y ar within sp cifie d rang s.
Strict monitoring of boil r wat r is mor
important for st am applications (and for op n
syst ms) wh r th r is a continuous inflaux of
mak up wat r. For hydronic units, typical
installations utiliz th boil r wat r in a clos d
syst m, which only occasionally r quir s th
addition of mak up wat r ov r th lif tim of th
boil r.
pH
The pH valu of your boil r wat r is a numb r
b tw n z ro and fourt n. Valu s b low s v n ar
acidic whil valu s abov s v n ar basic.
The pH factor is th most important factor
inflau ncing scal forming or th corrosiv t nd nci s
of boil r wat r. It should b adjust d to b tw n a
minimum of 9.0 and 11.0 to pr v nt acidic corrosion
of boil r tub s and plat s and to provid for th
pr cipitation of scal forming salts.
- 23 -
Note: For hydronic situations where the system is
not closed, the following water treatment
guidelines still apply and become even more
critical!
Note: The guidelines in this section are to be
used in conjunction with the advice of a water
treatment specialist.
Содержание WOOD GUN Super E210
Страница 2: ......
Страница 57: ...Appendix B Wiring Diagrams 51 ...
Страница 58: ...Appendix C Exploded Parts Drawings 52 ...
Страница 59: ... 53 ...
Страница 60: ... 54 ...
Страница 66: ...Appendix F Boiler Piping and Ducting Examples 60 ...
Страница 67: ...Wood Gun Air Inlet Ducting Installations 61 ...
Страница 70: ...APPENDIX G Markings 64 ...
Страница 71: ...Datalabel 65 ...