Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 65 of 91
P017455 – Rev. C
9.11.6
Press the
RESET
Button
to clear
the alarm.
If you are unable to create a High Outlet
Pressure Alarm as described, see section
13.6 for troubleshooting information.
9.12 Testing Low Outlet Pressure Alarm
9.12.1
Make a note of the current
Outlet Pressure (
OUTP
) reading.
9.12.2
Loosen the retaining nut on the Outlet Pressure Regulator.
9.12.3
Turn knob counter-
clockwise until Outlet
Pressure (
OUTP
) reading
drops below the low
outlet pressure threshold
(0.3 PSI, 2.1 KPA
default). After one (1)
minute, the Low Pressure
Alarm should appear on the display.