Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 60 of 91
P017455 – Rev. C
With Compressor running:
9.8.2
Verify the compressor shuts down when the tank pressure (
TANK
) reaches
50 PSI
(
344.7 KPA)
.
If the tank pressure (TANK) fails to reach 50 PSI (344.7 KPA), see section 13.15
for troubleshooting information.
With Compressor NOT running:
CAUTION
: Be careful when removing Air hose. System is pressurized.
9.8.3
Depressurize air Dryer (see section 8.3.3)
9.8.4
Verify the compressor turns on when the tank pressure (
TANK
) falls to
20
PSI
(
137.9 KPA)
.
9.8.5
Reconnect air hose.
If the Compressor Cycling fails either test described, it indicates a problem with
the Control Board which will need to be replaced. See sections 11.1 for part
detail and 11.4 for ordering information.