Altec AIR, LLC
P210WLP Series Air Dryer User’s Guide
Page 63 of 91
P017455 – Rev. C
9.10.6
Power the air Dryer
ON
.
Allow the Humidity reading to rise
over 10.0%.
9.10.7
After one (1) minute,
verify that a Humidity Alarm
appears, and the Dryer goes into
SHUTDOWN
mode.
9.10.8
Replace the
Humidity Sensor
into the Humidity
Block.
9.10.9
Press the
RESET Button
to clear
the Humidity alarm.
If you are unable to create a Humidity /
Shutdown alarm as described, see section
13.10 for troubleshooting information.