13.7  Low Outlet Pressure Alarm 

Possible Cause 

Check 

Corrective Action 

Outlet Pressure set too 
low 

Verify Outlet Pressure 
(

OUTP

) reading  

(section 8.5.5.1  ) 

Adjust outlet pressure 
regulator (section 8.10 ) 

Low Outlet Pressure 
Alarm set point too 
high 

Verify Low Outlet 
Pressure Alarm set 
point 
(section 8.7) 

Lower the Low Outlet 
Pressure Alarm set 
point (section 8.7) 

Leak in the air system 

With no outlet flow, 
test fittings and hoses 
for leaks (section 9.13 ) 

Tighten any loose 
connections as required 

 

13.8  

Can’t Create a Low Pressure Alarm 

Possible Cause 

Check 

Corrective Action 

Defective Outlet 
Pressure Regulator 

Verify that the Outlet 
Pressure Regulator can 
be adjusted 
(section 8.10 ) 

Replace Outlet Pressure 
Regulator if unable to 
adjust pressure  
(section 11.1) 

Low Outlet Pressure 
Alarm set point lower 
than default setting 
 

Verify Low Outlet 
Pressure Alarm set 
point 
(section 8.7) 

Adjust Outlet Pressure 
Regulator so that Outlet 
Pressure (

OUTP

reading drops below 
verified set point 
(section 9.12 ) 

Defective Control 
Board 

Verify that the Outlet 
Pressure (

OUTP

reading is lower than 
the Low Outlet 
Pressure Alarm set 
point (above) 

Replace Control Board 
(section 11.1 ) if Outlet 
Pressure (

OUTP

reading is under 
verified Low Outlet 
Pressure Alarm set 
point for more than 1 
minute and fails to 
create an alarm. 

 

Содержание Puregas P210W2LP

Страница 1: ...P017455 Rev C P210WLP Series Air Dryer User s Guide Models covered P210WLP P210W2LP P212WLP P212W2LP...

Страница 2: ......

Страница 3: ...AIR com 2 Introduction PLEASE READ THIS USER S GUIDE THOROUGHLY AND SAVE FOR FUTURE REFERENCE This User s Guide is provided for the benefit of our customers and contains information and direction spec...

Страница 4: ...pen Panel 41 8 9 Setting the System Pressure 41 8 10 Setting the Outlet Pressure 41 8 11 Connecting to Common Alarm Terminals 42 8 12 Connecting via Web Browser 43 8 13 Using the Status Screen 45 8 14...

Страница 5: ...Pressure Alarm 79 13 9 High Humidity 80 13 10 Can t Create a High Humidity Alarm Shutdown 81 13 11 High Duty Cycle Alarm 81 13 12 High Cabinet Temperature Alarm 81 13 13 Inconsistent Heatless Dryer Cy...

Страница 6: ...ttention for these warnings and read them as you encounter them WARNING For your safety all the information in this User s Guide must be followed to minimize the risk of electrical shock and prevent p...

Страница 7: ...not supplied by Altec AIR is NOT RECOMMENDED AND MAY VOID THE WARRANTY IMPORTANT Performing routine maintenance as outlined in the Maintaining Your Dryer section will ensure optimal performance over t...

Страница 8: ...indoor use The P210WLP Series Air Dryers employ a fully digital operating platform offering the most accurate readings of Dryer variables removable access panel allowing easier access for adjustment a...

Страница 9: ...2 RH Less than 40 F C Atmospheric Dew Point Compressor Type Oil less Piston Type Drying Method Heatless Desiccant Optimal Operating Temperature Range 40 85 F 5 30 C Ambient Unit will go into SHUTDOWN...

Страница 10: ...the coalescing filter 5 Heatless Dryer Removes moisture from the compressed air 6 Capacity Control Valve Regulates system pressure and prevents air from bleeding back through the heatless dryer 7 Air...

Страница 11: ...ed that you remove all jewelry before performing any procedures WARNING Internal surfaces may be hot Use care when coming into contact with internal components as there is a potential for some of thes...

Страница 12: ...ify the installation location of the air Dryer 6 2 3 1 Well ventilated and free from abrasive dust or chemicals 6 2 3 2 Ambient temperature is between 40 and 85 F 5 and 30 C for optimal performance NO...

Страница 13: ...s 1 Drawer Slide Pair 1 User s Guide not shown 1 Installation Hardware Kit 1 36 Purge Drain Tube 6 4 Required Tools and Materials Medium adjustable wrench Phillips Head Screwdriver Box Cutter Loctite...

Страница 14: ...company prior to continuing the installation procedures 6 5 4 Remove the wooden shipping block from the compressor assembly by removing the single Philips head screw and pulling the block free 6 5 5 R...

Страница 15: ...ns 6 5 7 1 Extend the drawer slide brackets and separate into two components by pressing down on the black lever and pulling apart 6 5 7 2 Install the smaller of the two slide components on the side p...

Страница 16: ...x 3 8 screws on each side Use Loctite to secure the screws 6 5 7 4 Install one of the mounting ear brackets on each side of the U shaped mounting bracket using two 10 32 x 5 8 screws two washers and...

Страница 17: ...sway see section 7 for ordering information 6 5 7 6 From a supported position lift and slide the unit into the U shaped bracket assembly that is installed in the server rack Take care to align the dra...

Страница 18: ...dryer The installation components required for wall mounting are NOT INCLUDED with the standard dryer see section 7 for ordering information 6 5 8 2 Install a wall mount bracket on each side panel of...

Страница 19: ...Cord to Dryer 6 5 11 Wire or plug the power cord into 110 125 VAC power outlet for the P210WLP model 208 253 VAC 1 phase power outlet for the P212WLP models o Line Black Brown o Neutral White Blue o...

Страница 20: ...he knob until the reading on the pressure gauge is 50 PSI 6 5 13 3 Push the knob in to lock 6 5 14 Let the Dryer run until the Humidity drops below 2 may take up to 15 minutes NOTE Press the RESET but...

Страница 21: ...s with a duty cycle of 10 or greater 6 5 17 Connect a 3 8 air supply line to the Outlet Port NOTE For all dryers with minimal flow install the Precision Bleed Orifice fitting to maintain a constant fl...

Страница 22: ...unning 6 5 20 1 Listen for any hissing sounds which may indicate a fitting or hose air leak With Compressor running 6 5 20 2 Use a 1 inch paint brush to dab soapy water on the air fitting or hose conn...

Страница 23: ...stem No alarms are present on the Display Panel 7 Registering Your Dryer Please take a moment to register your PUREGAS P210WLP Series Air Dryer Registering is necessary to activate the Limited Warrant...

Страница 24: ...ire the equipment to be running creating a situation for potential electrical shock It is highly recommended that you remove all jewelry before performing any procedures WARNING Internal surfaces may...

Страница 25: ...For all dryers with minimal flow install the Precision Bleed Orifice fitting to maintain a constant flow of air 8 2 2 Power the Dryer ON CAUTION Be careful when removing outlet plugs or connected Air...

Страница 26: ...until all the air pressure is released 8 3 4 Close Top Panel 8 4 Powering the Dryer ON OFF 8 4 1 POWER Switch Controls the main power to the Dryer CAUTION Incoming power to Dryer must be 15 amp servic...

Страница 27: ...ion screen on the display When pressed again it will allow the information screens to begin cycling again 8 5 4 Arrow Buttons Used to access navigate and change values in the Set Point Adjust screens...

Страница 28: ...compressor ran during the last Air Tank pressurization cycle TOTAL Number of hours of compressor run time since the total run time value was manually reset 8 5 5 3 System Status SYS STATUS Signal to...

Страница 29: ...Low Outlet Pressure Alarm Occurs when the Outlet Pressure OUTLET drops below the alarm set point for more than one 1 minute See section 13 7 for troubleshooting information 8 6 3 High Humidity Alarm...

Страница 30: ...ing information 8 6 5 High Compressor Last Run Time Alarm Occurs when the compressor takes longer to pressurize the air tank than the set point for the alarm See section 13 17 for troubleshooting info...

Страница 31: ...alarms can be modified to levels more closely based upon your specific application NOTE Reference Appendix Section 14 2 for Limits and Defaults 8 7 1 Navigating the Setup Menus 8 7 1 1 From any of the...

Страница 32: ...arm condition on its own without signaling an alarm o ON default waits one 1 minute before signaling alarms o OFF Signals alarms immediately 8 7 2 2 From the system setup menu screen press the Up Down...

Страница 33: ...ss the Up Down Arrow Buttons to navigate between the system setup options to locate RESET COMPRESSOR TOTAL TIME 8 7 3 3 Press the Enter button to enter the change value screen 8 7 3 4 Press the Right...

Страница 34: ...default values If NO is selected the unit will not be reset to factory values and all previous setpoints will be retained 8 7 4 7 Press the Left Arrow Button to escape to the system setup menu screen...

Страница 35: ...Press the Enter button to enter the change value screen 8 7 6 3 Press the Right Left Arrow Buttons to move the underscore beneath the digit to change 8 7 6 4 Press the Up Down Arrow Buttons to change...

Страница 36: ...oHigh Duty Cycle Alarm threshold for high compressor duty cycle oComp Last Run Alarm threshold for compressor last run time 8 7 7 2 From the Alarm Setup menu screen press the Up Down Arrow Buttons to...

Страница 37: ...le alarm threshold menu screen 8 7 7 9 Press the Left Arrow Button to escape to the home screens 8 7 8 Set IP Address 8 7 8 1 From the network setup menu screen press the Up Down Arrow Buttons to navi...

Страница 38: ...ove the underscore beneath the digit to change 8 7 9 4 Press the Up Down Arrow Buttons to change the value of the selected digit Press the Right Left Arrow Buttons to navigate to additional digits to...

Страница 39: ...the new value If NO is selected the Gateway address will not be set to the new value and the previous Gateway address will be retained 8 7 10 7 Press the Left Arrow Button to escape to the Network Set...

Страница 40: ...s 123456 The keyword can be modified to any 6 digit number of the user s choice 8 7 12 2 From the system setup menu screen press the Up Down Arrow Buttons to navigate between the system setup options...

Страница 41: ...latches and remove the top panel 8 9 Setting the System Pressure With Compressor running 8 9 1 Open Panel see section 8 8 8 9 2 Pull the Capacity Control Valve knob out 8 9 3 Turn the knob until the...

Страница 42: ...lock value in place 8 11 Connecting to Common Alarm Terminals 8 11 1 Wire the Alarm Harness to monitoring device using the table below for reference Wire Wire Color Function Power Fail 13 RED SHORT o...

Страница 43: ...wser If the Air Dryer IS NOT connected to an IP network and has not been configured with IP information Use the default IP Address 192 168 1 100 of the air dryer to connect Use an IP Cable may require...

Страница 44: ...of Set Points Setups and Keyword can be made in this screen Event Screen Displays all events such as alarms changes made and alarm resets registered by the P210WLP Series Air Dryer This screen is inf...

Страница 45: ...P017455 Rev C 8 13 Using the Status Screen Displays the readings and alarms monitored in the P210WLP Series Air Dryer Provides remote ALARM RESET Readings are displayed in BLACK unless an alarm is pr...

Страница 46: ...3 1 Resetting an Alarm 8 13 1 1 Click on the ALARM RESET Button to remotely reset Air Dryer alarms displayed on Status Screen 8 13 1 2 Enter Keyword default is 123456 8 13 1 3 Click on SUBMIT Button w...

Страница 47: ...iguration of Set Points Setups and Keyword can be made in this screen NOTE Reference Appendix section 14 2 for Limits Defaults and Formats Values in BLUE represent the current setting The ENTER Button...

Страница 48: ...pe in the new value 8 14 1 3 Click the ENTER Button when done 8 14 1 4 Enter Keyword default is 123456 8 14 1 5 Click on SUBMIT Button when done This will lock in the new setting value 8 14 2 Changing...

Страница 49: ...all events such as alarms changes made and alarm resets registered by the P210WLP Series Air Dryers This screen is informational only Click on the column headings to sort data according to that colum...

Страница 50: ...column Click the Arrow Buttons to navigate through all the event log pages 8 17 Using the Firmware Screen Displays the current firmware version and date of the P210WLP Series Air Dryers Current Versio...

Страница 51: ...e BROWSE Button allows you to locate the new firmware file The ACCEPT Button is used to change values Keyword validation is required to update firmware 8 17 1 Updating the Firmware 8 17 1 1 Click on B...

Страница 52: ...the P210WLP Series Air Dryer is dependent upon the specific SNMP Management software used on your network This software requires a SNMP Definition Configuration File MIB file in order to properly com...

Страница 53: ...ing a situation for potential electrical shock It is highly recommended that you remove all jewelry before performing any procedures WARNING Internal surfaces may be hot Use care when coming into cont...

Страница 54: ...2 3 Use an Amp Meter to measure the running amps With the compressor running the running amps should measure 1 0 amp or below 9 2 4 Close Panel If the compressor measures over 1 0 running amps see se...

Страница 55: ...3 Slide off clear plastic terminal block cover With the Compressor running 9 3 4 Use a Voltmeter to measure across the board terminals where wires 6 and 7 are connected The voltage should measure 115...

Страница 56: ...If any of the voltage measurements are different than indicated above the Control Board is defective and should be replaced See sections 11 1 for part detail and 11 4 for ordering information 9 4 Mea...

Страница 57: ...incoming voltage measures less than indicated above it is recommended that steps be taken at your facility to increase the power to the recommended level of voltage 9 5 Testing Consistent Heatless Dr...

Страница 58: ...scribed see section 13 13 for troubleshooting information 9 6 Measuring Heatless Dryer Solenoid Voltage With the Compressor running 9 6 1 Locate the Heatless Dryer Cycle Timer The timer has two 2 sets...

Страница 59: ...being blown outwards NOTE Fan will turn OFF when the cabinet temperature is below 80 F 27 C If the fan is not blowing air outwards as described Verify the cabinet temperature is above 90 F 32 C Check...

Страница 60: ...ubleshooting information With Compressor NOT running CAUTION Be careful when removing Air hose System is pressurized 9 8 3 Depressurize air Dryer see section 8 3 3 9 8 4 Verify the compressor turns on...

Страница 61: ...ing when the compressor turns on 9 9 2 Depressurize air Dryer See sections 11 1 for detail This prevents the compressor from shutting down When the compressor runs for 5 00 minutes unless adjusted to...

Страница 62: ...g Air hose System is pressurized 9 10 1 Power the air Dryer OFF 9 10 2 Depressurize air Dryer see section 8 3 3 9 10 3 Disconnect the humidity sensor from the control board lead 9 10 4 Unscrew and rem...

Страница 63: ...over 10 0 9 10 7 After one 1 minute verify that a Humidity Alarm appears and the Dryer goes into SHUTDOWN mode 9 10 8 Replace the Humidity Sensor into the Humidity Block 9 10 9 Press the RESET Button...

Страница 64: ...pressure regulator 9 11 3 Turn knob clockwise until Outlet Pressure OUTP reading climbs over the high outlet pressure threshold 7 5 PSI 51 7 KPA default After one 1 minute the High Pressure Alarm shou...

Страница 65: ...6 for troubleshooting information 9 12 Testing Low Outlet Pressure Alarm 9 12 1 Make a note of the current Outlet Pressure OUTP reading 9 12 2 Loosen the retaining nut on the Outlet Pressure Regulato...

Страница 66: ...2 6 Press the RESET Button If you are unable to create a Low Outlet Pressure Alarm as described see section 13 8 for troubleshooting information 9 13 Testing Air Fittings Hoses for Leaks NOTE This is...

Страница 67: ...t 10 Maintaining Your Dryer In order to ensure that your P210WLP Series Air Dryer continues to operate efficiently and reliably Altec AIR recommends performing preventative maintenance procedures at t...

Страница 68: ...s recommended that maintenance be performed more frequently 10 1 Safety Warning Information WARNING Extreme care should be exercised to avoid contact with live electrical circuits Many procedures perf...

Страница 69: ...ed in the Maintaining Your Dryer section will ensure optimal performance over the lifecycle of your Air Dryer IMPORTANT After performing any maintenance always soap test pressure fittings to check for...

Страница 70: ...and must be 208 253 VAC for P212WLP models 9 4 Test High Low Outlet Pressure Alarms 9 11 9 12 Set System Pressure 50 PSI 8 8 Set Outlet Pressure 8 10 Test Consistent Heatless Dryer Cycling 9 5 Test Fa...

Страница 71: ...ion 1 Year 2 Year 3 Year 4 Year 5 Year Install Annual Maintenance Kit 11 3 Measure Record Compressor Amp Draw 9 2 Set System Pressure 50 PSI 8 8 Set Outlet Pressure 8 10 Test Consistent Heatless Dryer...

Страница 72: ...Recommend Spare Precision Bleed Orifice P013349 1 Heatless Dryer Assembly See section 11 2 for detail 1 Fan P013720 1 Capacity Control Valve P017421 1 1 Humidity Sensor P013403 1 Air Compressor 115V U...

Страница 73: ...Dryer Assembly Parts Description Part Number Quantity Heatless Dryer 115V Units 230V Units MDH1 ALE S68 MDH1 DLE S68 1 1 Coalescing Filter Assembly P017636 1 Desiccant Chamber 51843 2 Cycle Timer 115...

Страница 74: ...are P017460 Server Rack Mounting Ear Kit Pair P017703 Cycle Kit Allows multiple dryers to be cycled P08033W Cycle Kit Interface Kit P012341 11 4 Ordering Parts from Altec AIR Once you have identified...

Страница 75: ...Rebuild o Replace desiccant o rings timer springs and complete solenoid assembly o Test proper component operation Desiccant Tower Repack o Clean out tower and replace desiccant filter and o ring Circ...

Страница 76: ...ction begins with the most likely cause s of the issue Otherwise they start from the simplest possibilities and progress to more complicated ones This troubleshooting guide is designed to be easy to f...

Страница 77: ...testing and maintenance of this air Dryer require the equipment to be running creating a situation for potential electrical shock It is highly recommended that you remove all jewelry before performing...

Страница 78: ...8 5 5 1 Raise High Outlet Pressure Alarm set point section 8 5 5 1 13 6 Can t Create a High Pressure Alarm Possible Cause Check Corrective Action Defective Outlet Pressure Regulator Verify that the O...

Страница 79: ...ate a Low Pressure Alarm Possible Cause Check Corrective Action Defective Outlet Pressure Regulator Verify that the Outlet Pressure Regulator can be adjusted section 8 10 Replace Outlet Pressure Regul...

Страница 80: ...within acceptable levels Raise High Humidity Alarm set point section 8 7 Over 10 not recommended Defective Humidity Sensor Perform the Testing Humidity Alarm and System Shutdown test section 9 10 Tro...

Страница 81: ...down section 11 1 13 11 High Duty Cycle Alarm Possible Cause Check Corrective Action High System Pressure Verify System Pressure section 8 9 Adjust System Pressure to 50 PSI 2 PSI section 8 9 High Do...

Страница 82: ...d Valves section 9 6 If 110 125 VAC for the P210WLP or 208 253 VAC for the P212WLP IS NOT present replace cycle timer section 11 2 13 14 Compressor Doesn t Operate Possible Cause Check Corrective Acti...

Страница 83: ...pressure setting on the capacity control valve Replace the compressor piston seal included in the Annual maintenance kit 13 16 Compressor Excessive AMP Draw Possible Cause Check Corrective Action Res...

Страница 84: ...ive control board Check that the compressor cuts out when the tank reading reaches 50 PSI 344 7 KPA section 9 3 Replace Control Board section 11 1 13 18 Can t Create a High Compressor Last Run Time Al...

Страница 85: ...Contacting Altec AIR Technical Support Please read the Before You Call Altec AIR section 13 1 Once you have exhausted all of the potential problems and solutions covered in the Troubleshooting Your D...

Страница 86: ...Altec AIR LLC P210WLP Series Air Dryer User s Guide Page 86 of 91 P017455 Rev C 14 Appendix 14 1 Wiring Diagram...

Страница 87: ...51 7 0 30 2 1 PSI KPA High Humidity Alarm 3 15 10 YES High Duty Cycle Alarm 0 99 70 High Compressor Last Run Time Alarm 2 00 10 00 5 00 Minutes High Cabinet Temperature Alarm 120 49 DEG F DEG C YES Co...

Страница 88: ...Compressor Total Run Time Reading Numeric Hours Compressor Last Run Time Reading Numeric Seconds System Status ON SHUTDOWN Compressor Status ON OFF Fan Status ON OFF Alarm Readings Read Only High Humi...

Страница 89: ...y the user and the user in turn should file any damage claim against the carrier All warranty items are F O B Broomfield Colorado Freight charges are the responsibility of the user This warranty shall...

Страница 90: ...olorado 80020 800 521 5351 303 427 3700 Fax 303 657 2233 info AltecAIR com www AltecAIR com 16 2 Sales 800 521 5351 option 2 Fax 303 657 2205 sales AltecAIR com parts AltecAIR com 16 3 Service 800 521...

Страница 91: ...__________________________________ ________________________________________________________________________ ________________________________________________________________________ ___________________...

Отзывы: