94
9.
SERVICE INFORMATION
Diagnostic Messages - SPANET TOPSIDE CONTROL PANEL
MESSAGE
CAUSE
ACTION REQUIRED
ER-2 HEATER PLUG
(no heat sensor communication)
Internal heater sensor communication
error
Turn mains power OFF, wait 5 minutes
then restart spa pool. Contact tech if
problem not resolved
ER-3 WATER PRIME
(prime has failed)
Air detected in heater tube
Low water level
Dirty filter cartridges
Airlock in pipe work
Slice-valves shut
Press Pump A button to retry water prime.
Check spa pool water level (refill if
necessary)
Remove and clean filter cartridges then
press Pump A button to retry prime
Bleed air from pipes by loosening barrel
unions on pumps
Check all slice valves are open
ER-4 THERMAL TRIP
(Heater thermal trip activated. Heater has
been active & has had insufficient water
flow over the element. Low or no water
flow has caused the heater temperature
to exceed its maximum limits & the spa
pool control has shut down operation to
prevent any damage to the heater unit)
Low water level
Airlock in pipe work
Dirty filter cartridges
Slice-valves shut
Check spa pool water level (refill if
necessary)
Bleed air from pipes by loosening barrel
unions on pumps
Remove and clean filter cartridges then
press Pump A button to retry prime
Check all slice valves are open
ER-5 POOL TOO HOT
(Water temperature too high, sensor
r45 degrees)
High ambient temp (summer)
Excessive filtration time
Turn off spa pool, remove cover and allow
water to cool before switching back on.
Reduce filtration time
ER-6 12V OVERLOAD
12V port current draw exceeding 1A limit
Call for service
ER-8 CTRL FAULT HVS
(heater relay on when it should be off)
Power Surge
Periods of low/high voltage
Water on controller terminal
Turn mains power OFF & back ON again
Inspect inside spa pool cabinet for leaks or
evidence of water exposure to controller.
Turn off spa pool, dry water/fix leak and let
controller dry out
ER-10 OVER CURRENT
(Mains 230v current draw above current
limited C.LMT detected)
Components current draw too large for
C.LMT setting
Power OFF/ON. Check C.LMT / L.SHD /
L.LMT settings are correct. Do elimination
test on components using the control
panel to identify which connection is
causing the fault
Содержание SPA POOL
Страница 1: ...1 SPA POOL MANUAL...
Страница 2: ...2...
Страница 31: ...31 Identify labeled parts on pages 74 77...
Страница 33: ...33 Identify labeled parts on pages 74 77...
Страница 35: ...35 Identify labeled parts on pages 74 77...
Страница 37: ...37 Identify labeled parts on pages 74 77...
Страница 39: ...39 Identify labeled parts on pages 74 77...
Страница 41: ...41 Identify labeled parts on pages 74 77...
Страница 43: ...43 Identify labeled parts on pages 74 77...
Страница 45: ...45 Identify labeled parts on pages 74 77...
Страница 47: ...47 Identify labeled parts on pages 74 77...
Страница 49: ...49 Identify labeled parts on pages 74 77...
Страница 51: ...51 Identify labeled parts on pages 74 77...
Страница 53: ...53 Identify labeled parts on pages 74 77...
Страница 55: ...55 Identify labeled parts on pages 74 77...
Страница 57: ...57 Identify labeled parts on pages 74 77...
Страница 59: ...59 Identify labeled parts on pages 74 77...
Страница 61: ...61 Identify labeled parts on pages 74 77...
Страница 63: ...63 Identify labeled parts on pages 74 77...
Страница 65: ...65 Controller located behind cabinet panel below the skimmer box Identify labeled parts on pages 74 77...
Страница 67: ...67 Identify labeled parts on pages 74 77...
Страница 69: ...69 Identify labeled parts on pages 74 77...
Страница 71: ...71 Controller located behind left hand side middle cabinet panel Identify labeled parts on pages 74 77...
Страница 73: ...73 Controller located behind left hand side middle cabinet panel Identify labeled parts on pages 74 77...
Страница 95: ...95...
Страница 96: ...96 0800 99 33 88 service alpinespas co nz www alpinespas co nz...