Service manual AlphaCom PSTN2IP ML transceiver              Rev. 1.6 10-09-2011            Page 32/65 

 

Factory Defaults

 

 

 

 
When pressing the button „Load factory defaults‟, the following screen will appear. Select the type of 
settings you want to put back to factory default and then press 

Load

. When selecting all options the 

AlphaCom PSTN2IP ML will be set back to factory defaults with the exemption of the MAC address. 
 
After selecting the appropriate factory defaults and pressing the 

Load

 button the factory defaults will be set 

and the AlphaCom PSTN2IP ML will restart. 
 

Содержание 003611

Страница 1: ...PSTN 2 IP ML Installation Manual...

Страница 2: ...exchange network The PSTN connection generates its own telephone line signals that imitate the signals of a public exchange network this makes it possible to receive alarm messages from the control p...

Страница 3: ...iver 2 as Double report function 37 PSTN back up function 38 LED indications on the PSTN2IP ML 38 DIPSWITCH settings of the PSTN2IP ML 40 New firmware flashen in the AlphaCom PSTN2IP ML bios flash 41...

Страница 4: ...be used in combination with virtually any alarm control panel supplied with an analogue alarm transmitter PSTN dialler The most common used protocols SIA HA SIA XSIA Contact ID Scancom slow 1400 Hz an...

Страница 5: ...event buffer of maximum 100 messages In the case that there are more than 100 messages in the event buffer then the oldest message will be erased and the new message will be added last in first out F...

Страница 6: ...ould be enabled see page 11 and 30 The security settings for the PSTN priority switch must be enabled to ensure that the control panel detects the disappearance of the analog telephone line if the IP...

Страница 7: ...nsmission over IP The AlphaCom XL complies with regulations D4 M4 T5 A3 S2 I3 A higher number indicates a better performance The regulations for AL1 are T2 T2 T2 D2 M2 S1 I2 The regulations for AL2 ar...

Страница 8: ...or Windows XP is used Cross over network cable for programming Attention Internet Explorer 5 0 or lower is not supported Also make sure the following information is known The protocol used by the anal...

Страница 9: ...pty Now start up your Internet browser and type in the address field 192 168 0 48 The login screen will now appear Follow the programming instructions as described at page 13 Set dipswitches 2 and 3 b...

Страница 10: ...ction This is not common when also connecting to the RS 485 bus If this is however the case then only the A B and 0V wires of the RS 485 bus must be connected The analog dialer of the control panel is...

Страница 11: ...er of J19 which is situated directly next to the priority relay The most upper pin pin 3 on J19 must be left open Also the PSTN tamper loop option must be enabled in the software See programming PSTN...

Страница 12: ...nection to the central station The integrated GPRS IP over GSM modules sends data packages over GPRS to the central station and more advanced and more reliable Finally a LAN connection has to be made...

Страница 13: ...address 192 168 0 48 with web port 80 to be used The username is admin and no password is needed to login Use this procedure only to program the personal Ethernet settings and username and password s...

Страница 14: ...e fixed IP address go to Start Control Panel and open the Dial up and Network connections The present network connections will now appear on the screen Right click on the active LAN connection and ope...

Страница 15: ...ternet protocol TCP IP and click Properties The following screen will appear Select the option Use the following IP address and enter 192 168 0 49 at the IP address field and 255 255 255 0 at the subn...

Страница 16: ...ssword and IP settings or whether the standard login name admin without password is used and the fixed IP address 192 168 0 48 with web port 80 Set dipswitch 3 to ON so the AlphaCom PSTN2IP ML can be...

Страница 17: ...different one The default port setting with dipswitch 3 set to OFF is port 80 This means when no other port is programmed the AlphaCom PSTN2IP ML can only be reached on port 80 It is recommended to u...

Страница 18: ...0 Ping statistics for 192 168 0 48 Packets Sent 4 Received 4 Lost 0 0 loss Approximate round trip times in milli seconds Minimum 4ms Maximum 4ms Average 4ms The IPCONFIG command can be used to show in...

Страница 19: ...no standard password can view and edit all configuration setting and view the status information If a wrong combination of username and password is entered to many times access to the web interface i...

Страница 20: ...us will be explained in the following pages of the manual The status screen is automatically refreshed every 10 seconds Possible messages for the transceiver Disabled The transceiver has not been conf...

Страница 21: ...IP ML is delivered with a factory default MAC address It is absolutely necessary to change the MAC address to the unique MAC address which is placed on a label on the AlphaCom PSTN2IP ML The label sho...

Страница 22: ...ettings and parameters Attention the AlphaCom PSTN2IP ML can work with both a fixed static or variable dynamic IP address When working with a dynamic IP address the AlphaCom PSTN2IP ML obtains its IP...

Страница 23: ...om the outside world To reach the AlphaCom PSTN2IP ML from the outside world the modem router must be programmed to allow an external IP address port to be forwarded to an internal IP address port In...

Страница 24: ...Service manual AlphaCom PSTN2IP ML transceiver Rev 1 6 10 09 2011 Page 24 65...

Страница 25: ...the AlphaCom PSTN2IP ML when using remote access Please be aware that the 4 transceivers must use a different local port number The default settings are 8000 8001 back up transceiver 1 8002 transceive...

Страница 26: ...hannel or transceiver 2 The programmed SIA code will mostly be determined together with the central station For a full description of SIA codes refer to appendix G If the option Activate PSTN prio on...

Страница 27: ...e used if the AlphaCom PSTN2IP ML is mounted outside the control panel casing It is advised to mount the AlphaCom PSTN2IP ML in the same casing as the control panel If the AlphaCom PSTN2IP ML is mount...

Страница 28: ...connecting non certified non tested products there should be no problems If you have any questions please contact the Alphatronics helpdesk Also an up to date list of products tested with the AlphaCom...

Страница 29: ...very to destination the analog dialer receives an acknowledgement from the PSTN2IP ML after the message has been received and acknowledged by the receiver in the central station For security reasons i...

Страница 30: ...AlphaCom XL Both devices communicate with each other via the hard wired Ethernet connection using a secured encrypted protocol With this solution it is possible to exchange a local serial connection...

Страница 31: ...PSTN2IP ML is powered by an external power supply through the 2 1mm jack connection This is not common when also connecting to the RS 485 bus If this is however the case then only the A B and 0V wire...

Страница 32: ...ear Select the type of settings you want to put back to factory default and then press Load When selecting all options the AlphaCom PSTN2IP ML will be set back to factory defaults with the exemption o...

Страница 33: ...ar In this screen the fixed IP address of the AlphaCom PSTN2IP will be displayed After restarting the AlphaCom PSTN2IP web browser can be reached through this IP address When using DHCP it is possible...

Страница 34: ...This makes it possible to program using a DTMF telephone It is now also possible to gain access to the AlphaCom PSTN2IP ML through IP address 192 168 0 48 and web port 80 The username is admin without...

Страница 35: ...Yes Configuration IP Dialer 2 21 IP address of central station receiver See comments in submenu 01 22 Port number central station receiver 23 Account number 24 Protocol of the central station receiver...

Страница 36: ...nnect the power supply of the AlphaCom PSTN2IP ML set dipswitch 2 to OFF and apply the power supply again Connect the analog alarmdialer of the control panel to the PSTN input on the AlphaCom PSTN2IP...

Страница 37: ...ML is connected to an AlphaVision NG control panel and the RS 485 connection fails the PSTN2P will detect this within 20 seconds and place a message in the buffer LED s 1 and 2 are used to indicate th...

Страница 38: ...with the monitoring station is fully restored the priority relay will deactivate and the messages will be send by the AlphaCom PSTN2IP ML again If using this option it is important that telephone numb...

Страница 39: ...ription of the INDICATION LEDs LED number Colour Description LED OP8 green Power supply present LED OP6 green LAN activity LED OP7 green LAN link Description of the STATUS LEDs LED number Colour Descr...

Страница 40: ...e programming the default username admin can be used a password is not required The AlphaCom PSTN2IP ML is accessible via IP address 192 168 0 48 and web server port 80 Programming via a DTMF telephon...

Страница 41: ...ntact the sales department of Alphatronics Attention after performing a firmware upgrade we strongly advise to check whether the AlphaCom PSTN2IP ML functions according to requirements Performing a fi...

Страница 42: ...ect the new firmware file Once the correct file has been selected press Upload to send the new firmware file to the AlphaCom PSTN2IP ML If the write protect jumper J44 is disabled the above message wi...

Страница 43: ...supply from the AlphaCom PSTN2IP ML Connect the serial programming cable between the computer laptop and the boxed header J1 on the AlphaCom PSTN2IP ML The boxed header is on the edge of the board nex...

Страница 44: ...phaCom PSTN2IP ML transceiver Rev 1 6 10 09 2011 Page 44 65 Figure 4 Connections for flash mode bios update RS 232 connector for flash mode Jumpers J43 and J44 in the flash mode Jumper J40 for flash m...

Страница 45: ...ton to select the correct location were the new firmware file has been placed on your PC In this example it is C ALPHACOM XL BIOS UPDATES ACOMXL_V1_1 MOT If it is not the correct file use the find but...

Страница 46: ...uccessful the message Connection complete will appear in the message box below After this the new firmware will be flashed into the processor of the AlphaCom PSTN2IP ML In the status bar you can see t...

Страница 47: ...f everything works according to specifications Remove the power supply from the AlphaCom PSTN2IP ML Remove the serial programming cable between the PC and the AlphaCom PSTN2IP ML Remove jumper J40 Put...

Страница 48: ...fully Choose for the option desktop icon During the installation deselect the boxes USB drivers and AutoUpdate that is displayed in the screen below Start the Flash Development Toolkit Basic 3 06 afte...

Страница 49: ...g cable is connected to When using a USB to serial converter ensure to select the correct virtual COM port that was made Press Next Make sure that the AlphaCom PSTN2IP ML is in the correct flash mode...

Страница 50: ...1 Page 50 65 If something goes wrong with the connection between the PC and the AlphaCom PSTN2IP ML for example the AlphaCom PSTN2IP ML is not powered up or not connected press Cancel If the connectio...

Страница 51: ...ect 25 00 MHz as frequency this is the correct value Press Next Press Next Press the Finish button The flash tool now tries to connect to the microprocessor in the AlphaCom PSTN2IP ML If the connectio...

Страница 52: ...ervice manual AlphaCom PSTN2IP ML transceiver Rev 1 6 10 09 2011 Page 52 65 Place a tick in the User Data Area box Use the find button right hand side of the screen to select the correct firmware file...

Страница 53: ...Service manual AlphaCom PSTN2IP ML transceiver Rev 1 6 10 09 2011 Page 53 65 Press the Program Flash button to start the flash procedure...

Страница 54: ...e text Image successfully written to device will appear in you screen Press the Disconnect button Tip the Disconnect procedure can also been done automatically by selecting the AutoDisconnect option i...

Страница 55: ...IP address from the DHCP server The AlphaCom PSTN2IP ML can also operate with a fixed IP address this is advisable if the AlphaCom PSTN2IP ML must be reached remotely When using a fixed IP address it...

Страница 56: ...DHCP server Is this the case check the IP address range distributed by the modem When using a fixed IP address for AlphaCom PSTN2IP ML us a fixed IP address outside this range to avoid conflicts with...

Страница 57: ...IP ML directly to a computer a cross over cable has to be used The wiring of a cross over cable is as follows Figure 4 Cross over cable wiring To connect the AlphaCom PSTN2IP ML to a router a standard...

Страница 58: ...67 TCP port for DHCP and BOOTP 68 TCP port for DHCP and BOOTP 69 TCP port for TFTP 70 Gopher 79 Finger 80 HTTP webserver 110 POP3 Post Office Protocol 119 NNTP Network News Transfer Protocol 137 139...

Страница 59: ...etwork device including router computers time servers printers and some telephones must have its own unique address A gateway such as an ADSL modem with an integrated router uses two IP addresses one...

Страница 60: ...ROUTER Many Internet connections use a modem with an integrated router This router often uses NAT A router can be seen as an intelligent switch which transports data packages from the internal networ...

Страница 61: ...her up to 4 times UDP is therefore mostly used by applications which need a fast transmission and a short reaction time and which does not require an active check on the reception of the messages Appl...

Страница 62: ...2 Scancom DTMF 1600 8 16 channels Yes Yes Yes Alphatronics CP 500 SIA HS Yes Alphatronics CP 407 Scancom DTMF 1600 8 16 channels Scancom DTMF 1400 8 16 channels Yes Yes Alphatronics CP 700 Scancom DT...

Страница 63: ...isarmed longer than the time programmed CJ Late Close Restoral of partition that was disarmed to long CL Closing Arming DR Duress Disarming under threat FA Fire Alarm FR Fire Restoral HA Holdup Alarm...

Страница 64: ...L combined kernel Firmware software of the ALPHACOM XL AlphaCom PSTN2IP ML Revision 1 1 19 03 2008 AlphaCom PSTN2IP ML pre release Revision 1 2 10 09 2008 AlphaCom PSTN2IP ML first release Revision 1...

Страница 65: ...ts of high quality components Most of the components used can be recycled The symbol means that this product should be recycled separately and not put in the normal waste bin together with normal hous...

Отзывы: