![alphatronics 003611 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/alphatronics/003611/003611_installation-manual_2906561021.webp)
Service manual AlphaCom PSTN2IP ML transceiver Rev. 1.6 10-09-2011 Page 21/65
Ethernet Settings
When pressing the button „General settings‟ in the status menu, the following page will appear. The settings
for the top button (Ethernet configuration) will be displayed on the screen. The other button that will appear
on the screen is
webserver configuration
. By pressing the
back to main menu
button you will return to the
status menu (this is the first page displayed after logging in).
Mac address:
The AlphaCom PSTN2IP ML is delivered with a factory default MAC address. It is absolutely necessary to
change the MAC address to the unique MAC address, which is placed on a label on the AlphaCom PSTN2IP
ML. The label shows only the last 6 digits of the unique MAC address for this unit. The first 6 digits
(00:01:3e) of the MAC address are the unique manufacturer code and should not be changed.
Attention:
As of the 1st of August 2011 the fixed part of the MAC address were changed to: 94-31-9B
Configuration Method
The PSTN2IP ML is by default configured as DHCP. This means, that the PSTN2IP ML obtains an IP
address from a DHCP server. By using the Alphatronics Equipment Discovery tool the obtained IP address
can be found easily.