Service manual AlphaCom PSTN2IP ML transceiver Rev. 1.6 10-09-2011 Page 16/65
Programming the AlphaCom PSTN2IP ML can be done using a commonly used web browser. Supported
versions are Internet Explorer
*)
(versions 6 and 7), Mozilla Firefox (version 1.5) and Opera (version 8.5).
*)
Attention:
Internet Explorer 5.0 (or lower) is
not
supported!
Before programming, the dipswitches on the AlphaCom PSTN2IP ML have to be set to the correct
positions.
Set dipswitch 1 to OFF to ensure that the factory defaults are not set.
Set dipswitch 2 to OFF to use the programmed login name with password and also the programmed
IP address / webserver port. Dipswitch 2 determines whether or not the AlphaCom PSTN2IP ML
requires a valid login name or password and IP settings or whether the standard login name (admin)
without password is used and the fixed IP address
192.168.0.48 with web port 80
.
Set dipswitch 3 to ON so the AlphaCom PSTN2IP ML can be reached via a standard web-browser.
If dipswitch is 3 is set to OFF the AlphaCom PSTN2IP ML cannot be reached in anyway via a web-
browser.
Ensure dipswitch 4 is set to OFF.
*)
Set dipswitch 2 to ON only to program the username, password and Ethernet settings. Restart the
AlphaCom PSTN2IP ML and set dipswitch 2 to OFF after programming these parameters.
Attention:
in this manual the standard
IP address is 192.168.0.48
and
web port 80
.
When the dipswitches are set correctly, use the browser to open http://192.168.0.48 (or the IP address that is
already programmed into the AlphaCom PSTN2IP ML). Remember to type in only
http://192.168.0.48
,
without „www‟. If required, the used port number can be placed behind the IP address, as such: