Fault
Display
Name of Protection
Possible Cause to Fault
Countermeasure
CCF1 Control circuit fault 0
Transmission between
the driver and the
keypad cannot be
established within 5s
after power is supplied
(when power is just
supplied)
Re-connect the keypad
Check the connection
line
Replace the keypad
Replace the control
board
CCF2 Control circuit fault 1
The -driver and the
keypad communicate
once after power is
supplied, but the
transmission fault
afterwards last for at
least 2s (in operation)
CCF3 EEPROM
fault
EEPROM fault with
the control board of
driver
Replace the control
board
CCF4 AD conversion fault
AD conversion fault
with the control board
of driver
Replace the control
board
CCF5 RAM
fault
RAM fault with the
control board of driver
Replace the control
board
CCF6 CPU
disturbance
Serious disturbance
MCU reading &
writing error with the
control board
The communication
line is connected
reversely or the DIP
switch is at wrong
position.
Reset via the button
“
STOP/RESET
”
Add the power filter at
the power side
additionally
Seek the technical
support
PCE
Parameter copying
error
Error with the
parameter copying
between the keypad
and EEPROM of the
control board
EEPROM of the
control board is
damaged
Repeat the copying
operation
Replace the control
board
Seek the technical
support
HE
Current detection
fault
Fault with the driver
current detection
circuit
The Hall components
are damaged
Replace the driver
Seek the technical
support