Chapter 4 Parameter Index
46
Function
code
Parameter name
Setting range
Factory
setting
Modify
flag
Modbus
address
PE.00
Type of latest
fault
(contd)
19: CCF1 control loop fault
1. The transmission
between the inverter and
the keypad still cannot be
established 5s after
powering on
20: CCF2 control loop fault
2. After connecting the
inverter and the keypad, the
transmission failure last for
more than 2 seconds
21: CCF3 EEPROM failure
22: CCF4 AD translation
exception
23: CCF5 RAM failure
24: CCF6 CPU is disturbed
25: PCE Parameter name
replication error
26: Reserve
27: HE Hall current detection
fault
28: De Cut-to-length
detection fault
29: Cue Feed off fault
NULL * 0F00
PE.01
Output frequency
when the latest
fault occurs
0~upper limit frequency
0.00Hz
*
0F01
PE.02
Set frequency
when the latest
fault occurs
0~upper limit frequency
0.00Hz
*
0F02
PE.03
Output current
when the latest
fault occurs
0 ~ 2 times of the rated
current
0.0A * 0F03
PE.04
DC busbar
voltage when the
latest fault occurs
0~1000V 0V
*
0F04
PE.05
Service condition
when the latest
fault occurs
0: StP Stop
1: Acc Acceleration
2: dEc deceleration
3: con Constant speed
StP * 0F05
PE.06
Fault history (the
latest)
The same with PE.00
NULL
*
0F06
PE.07
Fault history 2
The same with PE.00
NULL
*
0F07
PE.08
Fault history 3
The same with PE.00
NULL
*
0F08