Chapter 4 Parameter Index
32
Function
code
Parameter
Setting range
Factory
setting
Modify
flag
Modbus
address
P3.16~
P3.17
Reserve -
- -
P3.18 Control
Enable
0: Terminals enable
1: Internal enabled
1 ×
0412
P3.19 Reserve
-
-
-
P3.20
Y1 terminal
function
0:NULL
1: Run
2: Ready
3: Reach the Speed
4: Orientation completed
5: Speed / position status
output
7: 0 speed operation
19: Fault output
3 *
0414
P3.21
Y2 terminal
function
2 *
0415
P3.22
Y3 terminal
function
4 *
0416
P3.23 Y4
(Reserve)
-
*
0417
P3.24
Relay 1
(TA/TB/TC)
Output function
selection
19 ×
0418
P3.25 Reserve
-
-
-
P3.26
Frequency
arriving detection
width
0.00~10.00Hz 2.50Hz
P4: Analog and Pulse Input and Output Terminals
Function
code
Parameter
Setting range
Factory
setting
Modify
flag
Modbus
address
P4.00
AI1 nonlinear
enable
0:Disable 1: Enable
0
×
0500
P4.01
Analog zero drift
value
0.000~1.000V Analog treated
as 0 when the scope of the
following (When the absolute
value of the bipolar)
0.00V
○
0501
P4.02 AI1
Offset
-5.000~5.000V
0
○
0502
P4.03
AI1 maximum
analog input
value
0~10.00V 10.00V
○
0503
P4.04 AI2
Offset
-5.000~5.000V
0
○
0504
P4.05
AI2 Analog input
filter time
constant
0~10.000V 10.0V
○
0505
P4.06 Reserve
-
-
-
P4.07
Analog filtering
time
0~1000ms 20ms
○
0507
P4.08 Reserve
-
-
-
P4.09
AI1 nonlinear
input value 1
0.000~10.000V 0
○
0509