1. Important Safety Instructions

1.1  Important Notice 

SAVE THIS MANUAL – This manual contains important Instructions that must be followed during the instal- lation 

and maintenance of the UPS.

 

The UPS has its own internal energy source (battery). A voltage may be present at the output termi- nals 

even when no AC input power is available.

 

Make sure that the AC utility outlet is correctly grounded.

 

Do not open the UPS, as there are no serviceable parts inside and your warranty will be void.

 

Do not repair the unit yourself. Contact your local supplier or your warranty will be void.

 

Make sure that the input voltage of the UPS matches the supply voltage.

 

To prevent the UPS from overheating, keep all ventilation openings unobstructed. Do not place any- thing 

on top of the UPS. Keep the UPS rear panel at least 20 cm away from the wall or other objects.

 

Make sure the UPS is installed in an appropriate environment where the ambient temperature is 0 to 40°C 

(32 to 104°F), and humidity is 30 to 90% non-condensing.

 

Do not install the UPS in direct sunlight. Your warranty will be void if the batteries fail.

 

Install  the  UPS  in  a  temperature  controlled  indoor  area  that  is  free  of  conductive  contaminants  (not 

designed for outdoor use).

 

Dusty, corrosive, or salty environments can damage the UPS.

 

Install the UPS away from objects that give off excessive heat and areas that are excessively wet.

 

Do not install the UPS in an environment with sparks, smoke or gas. Not for use in a computer room as 

defined in the Standard for the Protection of Electronic Computer/Data processing Equipment,

 

ANSI/NFPA 75.

 

If liquids enter into the UPS or foreign objects are dropped into the unit, the warranty will be void.

 

The battery will gradually discharge if the system is unused for extended periods.

 

If unused, recharge the UPS every 2 to 3 months. If this is not done, the warranty will void. The batter- ies 

will automatically be recharged and kept in good condition if the UPS is installed and used.

 

This  UPS  supports  electronic  equipment  in  offices,  telecommunications,  process  control,  medical  and 

security applications. Only authorized personnel must install the UPS in the following locations:

 

a. Medical applications directly related to human life.
b. Elevators, metro (subway) system or any other equipment related to human safety.
c.

Public security system or critical computer systems.

Do not install the UPS in an environment with sparks, smoke or gas. Not for use in a computer room as 

defined in the Standard for the Protection of Electronic Computer/Data processing Equipment, ANSI/ NFPA 

75

 

Make sure the UPS is completely switched off when moving the UPS from one place to another. It may 

cause electrical shocks if the output is not completely switched off.

 

Page 

3

 to 

32

Содержание Sentra XL

Страница 1: ...User Manual Sentra XL...

Страница 2: ...4 1 Connect Utility and Load 17 4 2 Connect Network Surge protection 18 4 3 Connect Computer Interface Port 18 4 4 Connect Extended Battery Bank 19 4 5 Connect Extended Battery Bank to UPS 20 4 6 REP...

Страница 3: ...3 7 Communication 28 7 1 DB 9 Connector 28 7 2 Options for Intellislot SNMP Card Optional 29 8 Specifications 30 9 Signalling Circuit Connections 31 10 Warranty and Service Information 32 Page 2 to 32...

Страница 4: ...the UPS Install the UPS away from objects that give off excessive heat and areas that are excessively wet Do not install the UPS in an environment with sparks smoke or gas Not for use in a computer r...

Страница 5: ...ck convertible design a single AVR boost and single buck pure sine wave output a user friendly LCD display a built in customer option slot hot swappable batteries and a USB RS232 communication interfa...

Страница 6: ...se of it properly 3 2 Unpacking 1 Take the UPS out of the PE foam 2 Remove the packing materials 3 A standard unit includes One 1 user manual One 1 AC input power cord not supplied with hard wired mod...

Страница 7: ...s below 1 Ensure there is at least 20 cm 8 inches of clearance between the rear panel of the UPS and the wall or other obstructions 2 Do not block the air flow to the ventilation openings of the unit...

Страница 8: ...tower mount stand alone or rack mount To install the UPS as a tower see Section 3 4 1 For rack mount see Section 3 4 2 3 4 1 Tower Mount Stand Alone Stand alone unit NOTE See Section 3 5 to rotate the...

Страница 9: ...9 3 4 2 Rack Mount Setup Step 1 Step 2 NOTE See Section 3 5 to rotate the LCD display to match the physical orientation of the unit Page 8 to 32...

Страница 10: ...Step 3 Step 4 Step 5 Page 9 to 32...

Страница 11: ...anel The front panel can be rotated to accommodate the orientation of the UPS To position the display to match the physical orientation of the unit pull the display out rotate it and then push it back...

Страница 12: ...ch 5 Battery replacement 6 Battery backup LED 7 Battery low 8 Bypass 9 Utility low UPS boost 10 Utility high UPS buck 11 UPS output indicator 12 Polarity error or ground fault 13 Overload 14 Load batt...

Страница 13: ...Output Circuit Breaker for 6 1000 model only 15A Output Circuit Breaker for 6 1500 model only 6 NEMA 5 15R Output Receptacles 7 Cooling vents 8 12 A input circuit breaker 1000 model only 15 A input ci...

Страница 14: ...ort 4 RS232 DB 9 port 5 1 15 A output circuit breaker for 6 1 5 2 20 A output circuit breaker for 6 2 6 1 NEMA 5 15R output receptacles 6 2 NEMA 5 20R output receptacles 7 Cooling vents 8 30 A input c...

Страница 15: ...circuit breaker for 6 1 5 2 20 A output circuit breaker for 6 2 6 1 NEMA 5 15R output receptacles 6 2 NEMA 5 20R output receptacles 6 3 NEMA 5 30R output receptacles 7 Cooling vents 8 30 A input circu...

Страница 16: ...rcuit breaker for 6 1000 model only 10 A output circuit breaker for 6 1500 mode only 6 IEC 320 C13 output receptacles 7 Cooling vents 8 8 A input circuit breaker 1000 model only 10 A input circuit bre...

Страница 17: ...ation switch 3 USB port 4 RS232 DB 9 port 5 3 10 A output circuit breaker for 6 3 6 3 Output IEC 320 C13 6 4 Input IEC 320 C20 7 Cooling vents 8 Input circuit breaker 9 IEC 320 C20 input socket 10 Ext...

Страница 18: ...series Model AILI XL 3000 to reduce the risk of fire connect only to a circuit provided with 30 amperes maximum branch circuit overcurrent protection in accordance with the National Electric Code ANSI...

Страница 19: ...on the rear of the UPS Use a network cable to connect the OUT jack to the network equipment 4 3 Connect Computer Interface Port Use the interface cable RS 232 or USB optional to connect the interface...

Страница 20: ...k with connectors that are a different color from the battery bank connector in the UPS UPS model Nominal system voltage connector color Battery bank model AILI XL 1000 VA 24 VDC red BBC AILI 1000 AIL...

Страница 21: ...21 4 5 Connect Extended Battery Bank to UPS Page 20 to 32...

Страница 22: ...facing with the REPO circuit so that the UPS input feeder breaker can be switched off to interrupt all sources of power to the UPS and connected equipment This must be done to comply with national and...

Страница 23: ...nds to switch off the UPS If you press the off button less than 3 seconds the UPS does not execute the shutdown command 2 In some cases the UPS will switch itself off because of an overload an output...

Страница 24: ...test procedure stops If the batteries are weak or dead the battery replacement symbol on the LCD panel appears steadily CAUTION The UPS will not provide any output power if the start up procedure has...

Страница 25: ...procedure has not completed properly even though the input power cord is connected to the wall receptacle CAUTION The battery is heavy pull the battery out onto flat stable surface CAUTION Do not disc...

Страница 26: ...2 12 VDC 7 0 Ah Toplite Guangzhou Technology Battery Co Ltd MH29104 NPW36 12 12 VDC 7 2 Ah First Power Technology Co Ltd MH28204 FP1270 12 VDC 7 0 Ah Shenzhen Center Power Technology Co Ltd MH25860 CP...

Страница 27: ...27 6 2 Replacing Batteries STEP 1 STEP 2 STEP 3 Page 26 to 32...

Страница 28: ...2200 3000 VA models Use scissors to cut the tie wraps Disconnect the cables Remove the batteries Page 27 to 32...

Страница 29: ...ale connector on the rear panel that allows the UPS to communicate with a computer with UPS software The connection provides serial communications for utility and battery signals Table G DB 9 pin assi...

Страница 30: ...ntellislot SNMP Card Optional When this card is plugged in it enables the user to communicate monitor manage and control the UPS remotely via standard network management protocol SNMP using the intern...

Страница 31: ...kup mode Overload Warning and Protection Normal mode 100 to 110 Continuous overload alarm 110 to 120 Buzzer continuously alarms shutdown after 10 minutes 120 Shutdown after 1 cycle minimum Backup mode...

Страница 32: ...in the following schematic Outlet Relay Switch Line Input K board Input Voltage Sensor Output Current Sensor Output Voltage Sensor Main Transformer D board I board To PC RS232 Port USB Port SNMP Port...

Страница 33: ...cost of shipping the repaired or replacement unit back to the customer Battery Warranty Battery warranty provided by Alpha is a three year full replacement warranty with a pro rated warranty for the f...

Страница 34: ...k energy com France and Benelux fbnl alpha outback energy com Spain spain alpha outback energy com Russia russia alpha outback energy com Africa africa alpha outback energy com Alpha and Outback Energ...

Отзывы: