background image

 

Aviem Pro   

User’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 

AVIEM PRO 1000VA/2000VA 

Uninterruptible Power System 

 

Содержание PRO 1000VA

Страница 1: ...Aviem Pro User s Manual AVIEM PRO 1000VA 2000VA Uninterruptible Power System ...

Страница 2: ...g the UPS in locations where there is standing or running water or excessive humidity Do not plug the UPS input into its own output Do not attach a power strip or surge suppressor to the UPS Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS To reduce the risk of overheating the UPS do not cover the UPS cooling vents ...

Страница 3: ...rom the mains hazardous voltage still may be accessible through supply from battery The battery supply should be therefore disconnected in the plus and minus pole of the battery when maintenance or service work inside the UPS is necessary The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible INTRODUCTION This UPS is specially designed for Pers...

Страница 4: ... time is shorten 1 Overload of the UPS 1 Remove some non critical load 2 Battery voltage is too low 2 Charge battery 8 hours or more 3 Battery defect due to high temperature operation environment or improper operation to battery 3 Replace with the same type of battery Mains normal but LED is flashing Power cord is loose Reconnect the power cord properly If any abnormal situations occur that are no...

Страница 5: ... unit and return it to the place of purchase 2 Charging This unit is shipped from the factory with its internal battery fully charged however some charge may be lost during shipping and the battery should be recharged prior to use Turn on the UPS Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for at least 6 hours with no load no electrical...

Страница 6: ...e the ambient temperature or humidity is high On the other hand place the UPS away from the monitor at least 20cm to avoid interference 4 Connection Plug the UPS into a 2 pole 3 wire grounded receptacle Then connect one computer related device into each of the power receptacles supplied on the back of the UPS 5 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS ...

Страница 7: ...t the UPS when AC utility power is not available simply press the power switch 7 Green Power Function All Aviem Pro UPS is equipped with Green Power Function For saving power and protecting battery the method of deep discharging protection is adopted on inverter mode ...

Страница 8: ... after complete discharge TRANSFER TIME Typical 4 8 ms INDICATOR Normal Green lighting AC Mode Green lighting Battery Mode Yellow flashing Fault Mode Red lighting AUDIBLE ALARM Backup Mode Sounding every 10 seconds Low Battery Sounding every 1second Overload Sounding every 0 5 second Fault Continuously sounding PROTECTION Full Protection Discharge overcharge and overload protection PHYSICAL Dimens...

Отзывы: