Performance data
SWCV 122(H)(K)3
SWCV 162(H)(K)3
for B0/W35 to EN14511
Partial load operation
kW ı COP
5,06 ı 4,87
9,42 ı 4,92
for B0/W45 to EN14511
Partial load operation
kW ı COP
4,78 ı 3,75
9,15 ı 3,85
for B0/W55 to EN14511
Partial load operation
kW ı COP
4,58 ı 3,13
9,06 ı 3,22
for B7/W35 flow of B0/W35
Partial load operation
kW ı COP
5,92 ı 6,08
11,31 ı 6,05
for B0/W35 to EN14511
min. I max.
kW ı kW
2,48 ı 13,56
3,2 ı 17,20
for B0/W45 to EN14511
min. I max.
kW ı kW
2,24 ı 12,88
2,58 ı 17,00
for B0/W55 to EN14511
min. I max.
kW ı kW
2,54 ı 12,53
2,47 ı 17,00
for B7/W35 to EN14511
min. I max.
kW ı kW
2,94 ı 15,82
4,00 ı 19,10
Cooling capacity at max. volume flow (B15/W25), units with passive cooling: Identifier K
kW
12,3
14,9
Limits of use
Heating circuit return min. I Heating circuit flow max.
°C
20 I 65
20 I 65
Heat source
min. I max.
°C
-5 I 30
-5 I 30
Additional operating points
…
B-9/W60
B-9/W60
Sound
Sound pressure level at 1m distance from edge of unit
min. I max.
dB(A)
29 ı 38
29 ı 36
Sound power level to EN12102
min. I max.
dB(A)
44 ı 53
44 ı 51
Heat source
Flow rate (pipe dimensioning)
l/h
3200
3900
Max. free heat pump pressure ∆p (with cooling ∆pK) ***) ı Volume flow
bar (bar) ı l/h
1,08 (1,03) ı 1270
0,88 (0,80) ı 2350
Approved anti-freeze
Monoethylene glycol I Propylene glycol I Methanol I Ethanol
• I • I • I •
• I • I • I •
Anti-freeze concentration: Minimum frost protection down to
°C
-15
-15
Max. allowable operating pressure
bar
3
3
Heating circuit
Flow rate (pipe dimensioning) I Min. volume buffer tank in series I Min. volume separation buffer tank
l/h | l | l
2300 ı - ı -
2900 ı - ı -
Max. free heat pump pressure ∆p (with cooling ∆pK) ı Volume flow
bar (bar) ı l/h
0,69 (0,65) ı 870
0,54 (0,50) ı 1600
Max. allowable operating pressure
bar
3
3
General unit data
Total weight (with cooling)
kg
168 (176)
180 (188)
Box weight (with cooling) ı Tower weight (with cooling)
kg (kg) ı kg (kg)
103 (111) ı 65 (65)
115 (123) ı 65 (65)
Refrigerant type ı Refrigerant capacity
… ı kg
R407c ı 2,0
R407c ı 2,20
Domestic hot water tank
Net volume
l
—
—
Impressed current anode
integrated: • yes — no
—
—
Domestic hot water temperature, heating pump mode I Electric heating element
up to °C ı up to °C
— I —
— I —
Mixed water quantity according to ErP: 2009/125/EC (at 40°C, draw-off of 10 l/min)
l
—
—
Standing loss according to ErP: 2009/125/EC (at 65°C)
W
—
—
Maximum pressure
bar
—
—
Electrics
Voltage code ı all-pole heat pump fusing *)**)
… ı A 3~N/PE/400V/50Hz ı C10 3~N/PE/400V/50Hz ı C10
Voltage code ı all-pole heat pump fusing *) + electric heating element **)
… ı A
—
—
Voltage code ı Control voltage fusing **)
… ı A 1~N/PE/230V/50Hz ı B10 1~N/PE/230V/50Hz ı B10
Voltage code ı Electric heating element fusing **)
… ı A 3~N/PE/400V/50Hz ı B16 3~N/PE/400V/50Hz ı B16
WP*): effect. Power input B0/W35 (50Hz) EN14511 I Power consumption I cosφ
kW ı A ı …
1,04 ı 1,7 ı 0,88
1,91 ı 3,1 ı 0,89
WP*): effective power input B0/W35 to EN14511: min. I max.
kW ı kW
0,53 ı 3,29
0,83 ı 4,62
WP*): Max. machine current I Max. power input within the limits of use
A ı kW
9,0 ı 5,5
10 ı 7,3
Starting current: direct ı with soft starter
A ı A
< 5 ı —
< 5 ı —
Degree of protection
IP
20
20
Electric heating element output
kW
9 ı 6 ı 3
9 ı 6 ı 3
Circulation pump power consumption, heating circuit I heat sour
min. — max.
W ı W
2 – 60 ı 3 – 180
2 – 60 ı 3 – 180
Other unit information
Safety valve, heating circuit I Heat source
included in scope of supply: • yes — no
• I —
• I —
Expansion valve, heating circuit I Heat source
included in scope of supply: • yes — no
— I —
— I —
Overflow valve I Changeover valve
integrated: • yes — no
• I •
• I •
Vibration isolators, heating circuit I Heat source
integrated: • yes — no
• I •
• I •
*) Only compressor, **) Follow local regulations, ***) Figures for 25% mono-ethylene glycol
813497b
813489d
Heating capacity ı COP
Heating capacity
Technical data / Scope of supply