24
Gerätebezeichnung
Heat pump type
Brine/water ı Air/water ı Water/water
• applicable ı — not applicable
Installation location
Indoors ı Outdoors
• applicable ı — not applicable
Conformity
CE
Performance data
Heating capacity/COP at
B0/W35
Standard point acc. to EN14511
2 compresssors
1 compresssor
kW ı …
kW ı …
B0/W45
Standard point acc. to EN14511
2 compresssors
1 compresssor
kW ı …
kW ı …
B0/W35
Standard point acc. to EN255
2 compresssors
1 compresssor
kW ı …
kW ı …
Limits of application
Heating circuit
°C
Heat source
°C
Additional operating points
…
Sound
Sound level measured at distance of 1m around the device (in free field)
dB(A)
Sound power level according to EN12102
dB
Heat source
Volume flow: minimum flow rate ı nominal flow rate ı maximum flow rate
l/h
Pressure loss heat pump ∆p (with cooling ∆pK) ı volume flow
bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı volume flow
bar (bar) ı l/h
Anti-freeze agent
monoethylene glycol
minimum concentration ı frost proof down to
% ı °C
Heating circuit
Volume flow: minimum flow rate ı nominal flow rate ı maximum flow rate
l/h
Pressure loss heat pump ∆p (with cooling ∆pK) ı volume flow
bar (bar) ı l/h
Free compression heat pump ∆p (with cooling ∆pK) ı volume flow
bar (bar) ı l/h
General unit data
Dimensions (see dimensional drawing for the specified unit size)
unit size
Total weight (including cooling)
kg (kg)
Additional weight module 1
kg
Additional weight module 2
kg
Connections
Heating circuit
…
Heat source
…
Refrigerant
Refrigerant type ı Quantity
… ı kg
Electric
Voltage code ı all-pole circuit breaker heat pump *)
… ı A
Voltage code ı circuit breaker control voltage *)
… ı A
Voltage code ı circuit breaker electric heating element *)
ı A
Heat Pump
Effective power consumption in standard point B0/W35 according to EN14511: Power consumption ı current consumption ı cosφ
kW ı A ı …
Maximum device current within the limits of application
A
Starting current: direct ı with soft starter
A ı A
Protection type
IP
Output electric heating element 3 ı 2 ı 1 phase
kW ı kW ı kW
Components
Circulating pump heating circuit at nominal flow rate: Power consumption ı current consumption
kW ı A
Circulating pump heat source at nominal flow rate: Power consumption ı current consumption
kW ı A
Passive cooling function
only for units with designator K: Cooling output at nominal volume flow (15 °C heat source, 25 °C heating water)
kW
Safety equipment
Safety component heating circuit ı Safety component heat source
scope of delivery: • yes — no
Heating and heat pump regulator
scope of delivery: • yes — no
Electronic soft starter
integrated: • yes — no
Expansion vessels
Heat source: Scope of delivery ı Volume ı Initial pressure
• yes — no ı l ı bar
Heating circuit: Scope of delivery ı Volume ı Initial pressure
• yes — no ı l ı bar
Overflow valve
integrated: • yes — no
Vibration decouplers
Heating circuit ı heat source
scope of delivery: • yes — no
UK813196 -c
*) comply with local regulations n.n. = not detectable
We reserve the right to modify technical specifications without prior notice.
UK830500/190402
© Alpha-InnoTec GmbH
Technical data / Scope of delivery