Send completion report for heat pump systems
and general checklist to the manufacturer’s factory
customer service department.
Outside of Germany:
Send completion report for heat pump systems
and general checklist to the manufacturer’s local
partner.
Overview “Customer service”.
The heat pump system will be commissioned by
customer service personnel authorized by the
manufacturer. There is a fee for commissioning!
SAFETY TEMPERATURE LIMITER
A safety temperature limiter is built into the electric
heating element (depending on model). In the event of a
malfunction in the heat pump or air in the system, check
whether the reset button of the safety temperature
limiter has tripped. If this is the case, push in the
button.
1 Safety temperature button on
electric heating element
2 Reset button
Dismantling
DANGER!
Danger of fatal injury due to electric
current!
Electrical connections may be installed
only by qualified electricians.
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
DANGER!
Only qualified heating or cooling system
technicians are allowed to remove the unit
from the system.
CAUTION.
The anti-freeze mixture of the heat source
must not be allowed to enter the sewer
system.
Collect anti-freeze mixture and dispose of
properly.
DANGER!
Only qualified cooling system technicians
are allowed to dismantle the unit and its
components.
CAUTION.
Recycle or provide for proper disposal of
unit components, refrigerants and oil in
accordance with the applicable regula-
tions, standards and directives.
REMOVAL OF THE BUFFER BATTERY
CAUTION.
Before scrapping the heating and heat
pump regulator, remove the buffer bat-
tery on the processor board. The bat-
tery can be removed using a side cutter.
Dispose of battery and electronic compo-
nents in keeping with environmental con-
siderations.