31
823142
Qh (kW)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
-20
-15
-10
-5
0
5
10
15
20
25
30
35
Temp„ (°C)
35°C 1VD
50°C 1VD
COP
1
2
3
4
5
6
-20
-15
-10
-5
0
5
10
15
20
25
30
35
Temp„ (°C)
Pe (kW)
0
1
2
3
4
5
6
-20
-15
-10
-5
0
5
10
15
20
25
30
35
Temp„ (°C)
∆p (bar)
0,0
0,1
0,2
0,3
0,4
0,0
1,0
2,0
3,0
4,0
5,0
“” (m³/h)
∆p”
Legend:
UK823129L/170408
“”
Volume flow, heating water
Temp„
Temperature, heat source
Qh
Heating capacity
Pe
Power consumption
COP
Coefficient of performance / efficiency rating
∆p”
Pressure loss heat pump
VD
Compressor(s)
We reserve the right to modify technical specifications without prior notice.
UK830502/190901
© Alpha-InnoTec GmbH
Performance curves
LW 120A