5.2.4. Time Period Charge and Discharge Mode
6.1 Function Description
A.Turn on the function of force charge
:
EMS->Setting-> Function->System Mode->
Force Charge->Enable;
B. Set up the first charge start time: EMS->Setting-> Function->System Mode-> Charge
Start Time 1;
C. Set up the first charge end time: EMS->Setting-> Function->System Mode-> Charge
End Time 1;
D. Set up the second charge start time: EMS->Setting-> Function->System Mode->
Charge Start Time 2;
E. Set up the second charge end time: EMS->Setting-> Function->System Mode-> Charge
End Time 2;
F. Set up the charge cut SOC of the system: EMS->Setting-> Function->System Mode->
Charge Cut SOC;
G. Turn on the function of allow discharge
:
EMS->Setting-> Function->System Mode->
Allow Discharge->Enable;
H. Set up the first discharge start time: EMS->Setting-> Function->System Mode->
Discharge Start Time 1;
I. Set up the first discharge end time: EMS->Setting-> Function->System Mode->
Discharge End Time 1;
J. Set up the second discharge start time: EMS->Setting-> Function->System Mode->
Discharge Start Time 2;
K. Set up the second discharge end time: EMS->Setting-> Function->System Mode->
Discharge End Time 2;
L. Set up the discharge cut SOC of the system: EMS->Setting-> Function->System
Mode-> DischargeCutSOC->11%;
D
E
F
Plug
Down button:
View the power in the viewing
interface, move right in the programming
interface and modify the flashing shift.
Connect to EMS or other meters through
network cable to realize communication between
devices.
Enter button:
Check the power in the viewing
interface and save the settings in the program-
ming interface.
A
B
C
Object
Name
Description
Display Screen
SET
Data display and setting display
Men u button:
Enter / Exit menu.
Up button:
View the voltage and current in the
viewing interface, move left in the programming
interface and modify the flashing shift.
METER INSTRUCTION
EMS OPERATION
20
21
Table 3 Function Description
Figure 6-1 Schematic diagram of the appearance of the meter
Meter Instruction
06
SET