ADM-VPX3-9Z2 User Manual
V1.1 - 16th January 2020
LEDs
Status
Flashing Green + Flashing Red (alternate)
Service Mode
Red
Missing application firmware or invalid firmware
Red + Green
Standby (Powered off)
Green
Running and no alarms
Flashing Green + Red
Attention - alarm active
Flashing Green + Flashing Red (together)
Attention - critical alarm active
Flashing Red
FPGA configuration cleared to protect board
Table 26 : System Monitor Status LEDs
3.10 FMC Interface and Front-Panel I/O
The FMC+ interface provides a high-performance and flexible front-panel interface through a range of
interchangeable, industry standard IO modules which connect at receptacle J1.
The FMC+ interface adheres to VITA 57.4. The ADM-VPX3-9Z2 utilizes all possible FMC+ connectivity. This
includes all GPIO, all MGT links, and all clock capable IO.
FMC I2C signal (SCL and SDA at C30 and C31) are connected to the system monitor microcontroller. They are
used to determine operating voltage during startup and are not accesable to the user.
The FMC Present signal (PRSNT_M2C_L at connector pin H2) is connected to the system monitor
microcontroller.
Note:
The ADM-VPX3-9Z2 supports only 1.8V and lower VADJ Voltages.
Page 19
Functional Description
ad-ug-1323_v1_1.pdf