background image

21

DRAINING OPERATION.

Your product is with shower technology, that means that most of the moistures will be drained through

the exhaust pipe.

This is automatic.

Sometimes there are too many moistures and some parts go in an inner water tank.

When the water tank is full, E2 error appears on VFD screen, unit “bip” several times and stops working.

Turn off the unit, put the movable water tank (16) under the drainage knob (17) and unscrew the knob

and rubber plug to let water flow out.

When water tank is empty, replace knob and rubber plug and restart the unit.

CLEANING

Before any cleaning operation, stop and unplug the unit.

Do not use chemical solvent.

Use a dry and wet cloth to clean the outside of the unit.

Anti dust air filter:

If the anti dust air filter is dirty, the air conditioner will be less performing.

Clean the filter at least every two months.

Remove filter support (8) as shown on the drawing.

Remove bio-filter, take and wash the filter (vacuum cleaner or water and drying).

Put the bio-filter the filter and its support back.

Bio-filter:

This filter is a non-washable filter: if Bio-filter becomes dark, change it. At least, replace the filter once a

year. 

DESCRIPTIF DE L’APPAREIL

4

1. Tableau de bord
2. Ailettes (sortie d’air)
3. Récepteur du signal de télécommande
4. Poignée
5. Entrée d’air
6. Roulette
7. Bouchon de vidange
8. Filtre à poussière
9. Cordon d’alimentation
10. Sortie d’air
11. Entrée d’air
12. Télécommande
13. Gaine d’évacuation
14. Adaptateur pour fenêtre
15. Liaison climatiseur/gaine
16. Bac pour récupérer l’eau
17. Manchon pour mur avec couvercle
18. Kit fenêtre

12

18

17

13

15

16

14

Содержание AC 10 FITP

Страница 1: ...s du recyclage de la r utilisation mat rielle ou par les autres formes de r utilisation des appareils usag s Veuillez vous adresser votre municipalit pour conna tre la d chetterie comp tente Instructi...

Страница 2: ...l ext rieur dans un environnement humide pr s d une baignoire d une douche ou d une piscine Ne pas immerger cet appareil ou le cordon d alimentation Cet appareil est livr avec un c ble d alimentation...

Страница 3: ...ater tank VFD screen display E1 Voltage is too high or too low Restart when voltage is normal Unit is damaged Make it repair by a qualified person When there is something wrong with your unit contact...

Страница 4: ...the unit Anti dust air filter If the anti dust air filter is dirty the air conditioner will be less performing Clean the filter at least every two months Remove filter support 8 as shown on the drawin...

Страница 5: ...ess TEMPS M when the unit is running Set remaining time before stopping using J Each pressure adds or removes half an hour from 0 5 to 12h Remaining time before stopping is displayed on VFD screen and...

Страница 6: ...ges according to following diagram LOW MEDIUM HIGH DRY ONLY MODE During the dry operation the fan speed cannot be adjusted Low speed will be set automatically Adjustment of the temperature will have n...

Страница 7: ...g 8 Fig 6 Fig 8 Fig 7 Fig 6 bis 7 MISE EN PLACE DE LA GAINE D VACUATION DE L AIR CHAUD Monter l extr mit 15 sur la gaine Positionner la gaine sur le climatiseur dans le logement arri re 10 A travers u...

Страница 8: ...ventilation utilis s La temp rature ambiante s affiche sur l cran VFD S LECTION DU MODE DE FONCTIONNEMENT Utiliser la touche MODE K pour changer de mode de fonctionnement Chaque pression modifie la f...

Страница 9: ...ue l on appelle IONS Il y a des ions positifs et des ions n gatifs La sensation de bien tre est li e la densit des particules lectriques nous entourant C est la charge en ions n gatifs qui est essenti...

Страница 10: ...ter le climatiseur positionner le bac eau amovible 16 sous le bouchon de vidange 7 retirer le bouchon de vidange pour laisser s vacuer l eau Lorsque le bac est vide replacer le bouchon de vidange et r...

Страница 11: ...i proc dera la endommag s r paration L appareil s arr te La programmation tait activ e Annuler la programmation automatiquement Pas d air froid en mode La temp rature de la pi ce est Fonctionnement no...

Страница 12: ...plied and recommended by the manufacturer This could be dangerous and may damage the appliance Do not use if power cord or appliance is damaged Only use this appliance for domestic purpose following t...

Отзывы: