FORM DOC 120 A
MU 7093 EN C
DUAL TRONIQUE
Page 38/69
This document is available on www.alma-alma.fr
BLOCKING PLAN
OFF
:
When choosing the compartment, there is no restriction of
choice. The user chooses a compartment compatible with the requested product
BLOCKING PLAN
ON
:
When choosing the compartment, only the compartments
containing the requested product are proposed. When a compartment is empty, it
won’t be available for a delivery until the user enters a new product quality via the
menu
LOADING PLAN
of the USER mode.
LOADING PLAN
OFF
LOADING PLAN
BLOCKING PLAN
OFF
BLOCKING PLAN
ON
Maintenance
PLAN ENABLED
(XX)
LOADING PLAN
ON
6.3.6 Sub-menu ADDITIVE TYPE
Access restricted to the Maintenance with red key
INJECTOR NB
: The injector(s) can be assigned to one or both measuring systems. The
presence of a second injector is possible only if the number of flaps and returns allows it.
See the table in ANNEX 3.
Then, for each injector, set the parameters that follow:
EMA/EMB
: When the system manages two measuring systems, choose the measuring
system (
CONFIGURATION>DUAL OPTION
), select the measuring system for additive
injection
Then configure the additive injection with the menus below:
ADDITIVE TIME
: Set the duration of the additive control before allowing a new order (in
tenth of a second). It corresponds to the control of the actuator to which is added a
relaxation of the same duration
FEEDBACK CTRL
: If this function is ON, the measuring system makes sure that the
injector piston moves.
LEVEL CTRL
:
If this function is ON, the measuring system controls the additive level in
the tank. Low level triggers an alarm.
ADDITIVE TYPE
FEEDBACK CTRL
LEVEL CTRL
FEEDBACK CTRL
OFF
FEEDBACK CTRL
ON
LEVEL CTRL
OFF
LEVEL CTRL
ON
INJECTOR
EMA
INJECTOR
EMB
Maintenance
0.5
ADDITIVE TIME
0
.5
ADDITIVE TIME
1
INJECTOR NB
2
INJECTOR NB
6.3.7 Sub-menu REMOTE CONTROL
Access restricted to the Maintenance with red key
This menu allows you to activate or not the operation with remote control.
REMOTE CTR
OFF
:
No remote control
REMOTE CTR
RC FIOUL
:
Activation of the operation with the RC FIOUL remote control
REMOTE CTR
RCT5
:
Activation of the operation with the RCT5 remote control, See GU
7098.