FORM DOC 120 A
MU 7093 EN C
DUAL TRONIQUE
Page 23/69
This document is available on www.alma-alma.fr
5.3 Menu LOADING PLAN
Depends on METROLOGICAL configuration. Not used if the function has not been activated.
The
LOADING PLAN
menu is used to display the quality and the quantity of the products available in each compartment according to the
information received from the embedded computing or entered manually. The volumes per compartment are be updated as the deliveries
and product movements continue. They will be displayed at the compartment selection.
In case of a blocking function, an empty compartment won’t be available for a delivery until you enter a new product quality via this menu. A
compartment is considered as empty if the end height is reached and if
CPT X EMPTY
is displayed during the delivery.
The loading plan can be entered manually:
ENTER PLAN
: For each compartment, select the product name and set the loaded volume. With DSPGI, the product name is blank. Then
you must validate the loaded plan
VALID LOADING PLAN:
This step validates the manually entered loading plan.
RESET PLAN:
The loading plan can be cancelled by this menu.
LOADING PLAN
ENTER PLAN?
>
VALID LOADING PLAN
PRODUCT
FUEL
1
CHOOSE COMPARTMENT
0
6
000
L
1/ /QUANTITY?
Select the product loaded in this
compartment (ex: FUEL)
Choose compartment
(ex: compartment 1)
Set the volume loaded in this
compartment (ex: 6000 l)
RESET PLAN
06000
L
COMPARTMENT 1 FUEL
05000
L
COMPARTMENT 2 FUEL
RESET PLAN