background image

24

Distributed by: AFW Access Systems
www.AnchorMiami.com (305)691-7711

This Gate Operator is built in the USA and 
complies with all requirements of 
Underwriters' Laboratories Standard UL-325.   
P/N 110136              Rev. F       December  2003

PHYSICAL 

PAD:

18-1/4” W x 18-1/4”D x 3”H Elevation 

OVERHEAD CLEARANCE: 

Minimum 25” Required 

UNIT SIZE: 

15”W x 19”D x 24-1/4” H 

FRAME: 

Welded, Uni-Body; Phosphatized And 

COVER: 

Architecturally Designed, Rust Free 
LLPE; Key Lock To Prevent 

SHIPPING WEIGHT: 

115 lbs. 

PRIMARY VOLTAGE: 

115 VAC, 60 Hz, Single Phase 

ELECTRICAL SOURCE: 

One 3-Wire, 15-Amp Service From 

CONTROL VOLTAGE: 

5 VDC 

RADIO RECEIVER POWER: 

24 VAC, 20 mA 

MOTOR: 

1/2 HP, 4.4 Amp, PSC, Instant 
Reversing, Thermally Protected (Manual 

AUTO TIMER-TO-CLOSE: 

Built-In, Adjustable From 2-60 Seconds 

ELECTRICAL 

DRIVE 

DRIVE SYSTEM: 

Gearbox; 10:1; With Bronze Worm & 
Pinion Gears 

TOTAL SPEED REDUCTION: 

22.2:1 

OUTPUT SHAFT: 

1” dia., Ball-Bearing Mounted 

DRIVE MECHANISM: 

18-Tooth Sprocket; #41 Roller Chain 

LIMITS: 

Independent Open & Close; Displaced 
Cam With Micro-Switch Contacts; 
Adjustable Without Tools 

OPERATOR LOCK: 

Electro-Mechanical, AC Solenoid; 
Engages On Close Limit, Drops Out If 
Power Is Interrupted 

MAX. GATE WEIGHT: 

1,100 lbs., Level Grade 

MAX. GATE WIDTH: 

29 ft. 

MAX. CYCLES PER HOUR: 

45 Open/Close Per Hour; 800 Open/
Close Per Day (All Calculations Based 
On Typical 20’ Gate On Level Grade) 

GATE SPEED: 

11.8 inches/second 

CAPACITIES 

Specifications subject to change without notice.  Consult the factory. 

Manufacturer’s Limited Warranty

Allstar warrants its gate operators to be free from defect in material and workmanship for a period of five (5) years from the date of purchase 
for single family home use and three (3) years from the date of purchase for multi-family and commercial use.  This warranty covers all 
components except the electronic circuit boards which are warranted for three (3) years from the date of purchase for single family home use 
and two (2) years from the date of purchase for multi-family and commercial use.  To obtain service contact your dealer.  

To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods from Allstar before 
returning the goods.  The goods must be returned with complete identification, with copy of proof-of-purchase, freight prepaid and in 
accordance with Allstar’s instructions or they will not be accepted.  In no event will Allstar be responsible for goods returned without proper 
authorization or identification. 

Goods returned to Allstar for warranty repair within the warranty period, which upon receipt by Allstar are confirmed to be defective and 
covered by this limited warranty, will be repaired or replaced at Allstar’s sole option, at no cost and returned pre-paid.  Defective parts will 
be repaired or replaced with new or factory rebuilt parts at Allstar’s sole option. 

This limited warranty does not cover non-defect damage, damage caused by unreasonable use, damage caused by improper installation or 
care, vandalism or lightning, fire or excessive heat, flood or other acts of God (including, but not limited to misuse, abuse or alterations, 
failure to provide reasonable and necessary maintenance), labor charges for dismantling or reinstalling a repaired or replaced unit, or 
replacement batteries. 

These warranties are in lieu of all other warranties, either expressed or implied.  All implied warranties of merchantability and/or fitness for a 
particular purpose are hereby disclaimed and excluded.  Under no circumstances shall Allstar be liable for consequential, incidental or 
special damages arising in connection with the use or inability to use this product.  In no event shall Allstar’s liability for breach of warranty, 
breach of contract, negligence or strict liability exceed the cost of the product covered hereby.  No person is authorized to assume for Allstar 
any other liability in connection with the sale of this product. 

This warranty gives you specific legal rights.  You may also have other rights which vary from state to state.  Warranty effective after June 1, 
2000. 

  TECHNICAL SPECIFICATIONS  

Содержание LEADER PLUS LP1000

Страница 1: ...rements for Vehicular gate operators LEADER PLUS Model LP1000 Heavy Duty Vehicular Slide Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 107063 Serial Date...

Страница 2: ...there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAU...

Страница 3: ...TE TESTED ON THE LOG LOCATED ON PAGE 2 OF THIS MANUAL See Figure 1 pg 2 Connections for External Entrapment Prevention Sensors Because all gate system installations are different the LP1000 control pa...

Страница 4: ...IAL HAZARD CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE Allstar strongly recommends the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handh...

Страница 5: ...be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATION WITH THE CONTROL BOX COVER REMOVED x ALWAYS TURN OFF THE...

Страница 6: ...tor The bolt pattern for the LP1000 is 12 3 16 wide by 12 1 4 long The two rear bolts closest to the gate should be no closer than 5 1 2 from the near side of the gate to allow sufficient clearance fo...

Страница 7: ...ol wires MUST NEVER be routed in the same conduit as A C power wires Always consult and follow all local electrical codes 106728 Figure 8 Chain Configuration Normal Drive Figure 7 Service Conduits 106...

Страница 8: ...d in wires need not be in PVC but must have at least six 6 twists per running foot For a saw cut installation observe the method recommended in Figurez10 for the corners When installing a two loop rev...

Страница 9: ...with the operator in place Before inserting the remaining redhead bolts make sure the operator is sitting level If any corners of the operator are resting above the pad slide flat washers under the op...

Страница 10: ...100 OHMS resistance and for more than 100 milliseconds duration Two of the inputs ALTERNATE and RADIO OPEN are momentary inputs where the signal must be released and re entered to be recognized The r...

Страница 11: ...parate from the receiver s output connection This is necessary as the LP1000 control board 24 VAC is isolated from chassis ground A 3 prong receiver CANNOT be installed in association with the LP1000...

Страница 12: ...factory configured for right hand installations If it is installed in a left hand installation make sure the main power switch is off and locate the 8 pin motor wire connector in the upper center of t...

Страница 13: ...limit nut two more slots to give the operator time to stop the gate after the limit switch has been activated Release the detent plate and make sure it drops into the slots on both limit nuts Manually...

Страница 14: ...he test mode the operator control board changes to a sleep mode and a low pulsed tone is heard from the audible output You can reset the operator for a renewed 20 test cycles by turning the power off...

Страница 15: ...rol board of the LP1000 operator See Figure 22 These lights are used to verify proper operation of the LP1000 TURN ON THE MAIN POWER SWITCH Remove the white high voltage connector from the control boa...

Страница 16: ...lots in either direction to fine tune the gate s limits of travel When final adjustment has been completed insure that the detent plate is firmly seated in the slots Review Figure 18 Page 13 SETTING T...

Страница 17: ...operator should respond to an obstruction not encountered by the other the gates will temporarily get out of sync Synchronization will be restored after the next input command cycle D STARTING THE OPE...

Страница 18: ...to terminals 3 or 13 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening directi...

Страница 19: ...19 D STARTING THE OPERATOR Figure 23 Wiring Schematic and Diagram 110146...

Страница 20: ...or Close Contact Sensor input or a Close Overload activation will cause the gate to stop pause and reverse for approximately 2 inches in the Open direction xIf the gate is moving in a Close direction...

Страница 21: ...ollowing safety features x Electric gate edges x Enclosed tracks x Vertical guard posts x Protective screen mesh x Photoelectric sensors x Instructional and precautionary signs x Covers for exposed ro...

Страница 22: ...mpensate for a poorly operating slide gate Correct all mechanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gat...

Страница 23: ...r 2 EA not shown 110136 Installation Owner s Manual 1 EA 24b 111886 Box Cover 4 x 2 Duplex Raised 1 EA OPERATOR EXPLODED VIEW 110153 OPERATOR PARTS LIST RISK OF ELECTROCUTION TURN OFF THE MAIN POWER S...

Страница 24: ...purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods f...

Отзывы: