The Allstar Leader Plus (LP1000) Vehicular Gate Operator will provide 
convenience and assurance to the ultimate users for many years.  It is 
ruggedly built of the finest materials and has been thoroughly inspected 
and tested at the Allstar factory.  It has many features that will aid in the 
installation and testing of the complete gate system.  The LP1000 is 
certified to comply with UL Standard for Safety 325, as revised March 
1, 2000. 

The LP1000 slide gate operator is designated a Class I Residential 
Vehicular Slide Gate Operator and is intended to operate a vehicular 
slide gate installed on a residential home, maximum of four single 
families in the dwelling, or a garage or parking area associated with 
such a home. The LP1000 vehicular gate operator is also designated 
Class II (commercial location or multi-family home); III (industrial 
location not intended to service the general public); and IV (secure or 
restricted access locations, i.e. airports and prisons).  

THE LP1000 

MAY BE USED IN ANY CLASS LOCATION. 

Because the LP1000 (as well as gate operators sold by other 
manufacturers) is designed to start and move gates weighing as much as 
1000 pounds, or more,---the LP1000 is capable of producing high levels 
of force.  It is important in the design of the total gate system that 
designers, installers and users be aware of the hazards that may be 
associated with the 

IMPROPER

 design, installation and use of 

vehicular gate systems and gate operators. 

The gate operator  is only one part of a complete automatic gate 
operating system.  As each location and usage is different, a properly 
designed system will include all applicable safety devices. 

As the designer and installer

 of the 

GATE SYSTEM

, you must 

advise the purchaser on the proper use of the gate system.  

The LP1000 with Allstar’s exclusive CGA2K™ Technology 
provides several features that can help reduce the hazards of your 
gate system. 

Built-In Overload Detector Sensing System 

The Allstar LP1000 has a built-in "overload detector" that can help 
reduce the hazards of your gate system.  This device, however, must not 
be considered as the primary defense system.  Consider all available 
options (electric leading edges, photoelectric sensors, protective screen 
mesh, etc) to eliminate hazards in your gate system design. 

The Allstar LP1000’s built-in overload detector will activate if there is 
an abrupt increase in motor current above that normally required to 
move the gate.  The overload detection point is an adjustable setting 
that must be determined at the time of installation.  This setting must be 
tested periodically to ensure proper operation. Diligent maintenance of 
the gate hinges and hardware will assure the most responsive operation 
of the overload detector.  See pages 14 and 16. 

ADVISE THE PURCHASER TO CHECK THE SENSITIVITY OF 
THE OVERLOAD PERIODICALLY AND, AFTER REMOVING 
THE CONTROL BOX COVER, LOG THE DATE TESTED ON THE 
LOG LOCATED ON PAGE 2 OF THIS MANUAL (See Figure 1, pg. 
2.) 

Connections for External Entrapment Prevention Sensors

Because all gate system installations are different, the LP1000 control 
panel provides independent connections for Open and Close non-
contact (photoelectric) and contact (edge) sensors.  In this way a 
photoelectric sensor could be utilized to guard the gate area when 
closing and an edge sensor would provide the protection when opening.  
Depending on the particular application a combination contact and non-
contact sensor protection system for the open and close directions may 
provide more effective entrapment protection than a single device for 
both directions.  See pages 4, 5, 18, 21, and 22. 

Audio Alarm and AlarmAble™ Open/Close Push Button Enable-
on-Alarm Only (Patent No. 6,611,205)  

The LP1000 has an audio alarm that sounds when a second occurrence 
of the built-in overload activation is registered before an end limit 
(open or close) is reached.  The alarm continues to sound warning until 
a fixed wire input is activated or five (5) minutes pass.  As with the 
built-in overload detector,  Diligent maintenance of the gate rollers and 
track will avoid nuisance operation of the overload detector and thereby 
avoid nuisance operation of the audio alarm.  Allstar’s patented 
AlarmAble™ Open/Close Push Button Enable-on-Alarm Only feature 
can be set to provide a secure control station that will be functional in 
an emergency  situation.  See pages 14, 16, and 22. 

SMART™  Self adjusting MAximum Run Timer 

The LP1000 has a 

S

elf adjusting 

MA

ximum 

R

un

T

imer, SMART™.  

The amount of time for the first few cycles of operation are registered 
and averaged within the motor controller circuitry.  After the first few 
initial cycles, if the gate is activated and no other command is given or 
an end limit (open or close) is not reached in the previously counted 
cycle time plus approximately 2 seconds, the operator will be turned 
off.  See page 17. 

OTHER FEATURES
Auto Close Timer:

  Adjustable from 2 to 60 seconds, provides an 

automatic closure of the gate from the full open position.  See page 15. 

Timer Re-close On/Off Switch:  

Enables an automatic closure of the 

gate from a partially closed position if the close movement  was 
initiated by the Auto Close Timer and the close cycle was interrupted 
by a non-contact (photoelectric) sensor input.  See page 15. 

Diagnostic LEDs on the Motor Controller Board:

  Provides a visual 

indication of the status of the gate system operation.  See page 15. 

PRE INSTALLATION NOTES 

NOTICE

T H E   I M P O R T AN T   S AF E G U AR D S   AN D 
INSTRUCTIONS IN THIS MANUAL  CANNOT 

COVER ALL POSSIBLE CONDITIONS AND SITUATIONS 
WHICH MAY OCCUR DURING ITS USE.  IT MUST BE 
UNDERSTOOD THAT COMMON SENSE AND CAUTION 
MUST BE EXERCISED BY THE PERSON(S) INSTALLING, 
MAINTAINING AND OPERATING THE EQUIPMENT 
DESCRIBED HEREIN.  DO NOT USE THIS EQUIPMENT FOR 
ANY OTHER THAN ITS INTENDED PURPOSE — 
OPERATING A SLIDE GATE. 

NOTICE

BEFORE ATTEMPTING INSTALLATION, 

 

READ THIS MANUAL CAREFULLY  SO YOU 

WILL BE THOROUGHLY FAMILIAR WITH THE 
FEATURES OF THE LEADER AND ITS PROPER 
INSTALLATION PROCEDURES. 

Содержание LEADER PLUS LP1000

Страница 1: ...rements for Vehicular gate operators LEADER PLUS Model LP1000 Heavy Duty Vehicular Slide Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCTIONS 107063 Serial Date...

Страница 2: ...there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instructions to avoid the hazard CAU...

Страница 3: ...TE TESTED ON THE LOG LOCATED ON PAGE 2 OF THIS MANUAL See Figure 1 pg 2 Connections for External Entrapment Prevention Sensors Because all gate system installations are different the LP1000 control pa...

Страница 4: ...IAL HAZARD CAN BE MINIMIZED BY INSTALLING A MESH SCREEN ON THE GATE Allstar strongly recommends the entire gate and adjacent fence area the gate covers when open be meshed or guarded such that a handh...

Страница 5: ...be exposed EVEN IF THE RED POWER LIGHT IS NOT LIGHTED HIGH VOLTAGE AC MAY STILL BE PRESENT ON TERMINALS L1 AND L2 NEVER LEAVE THE INSTALLATION WITH THE CONTROL BOX COVER REMOVED x ALWAYS TURN OFF THE...

Страница 6: ...tor The bolt pattern for the LP1000 is 12 3 16 wide by 12 1 4 long The two rear bolts closest to the gate should be no closer than 5 1 2 from the near side of the gate to allow sufficient clearance fo...

Страница 7: ...ol wires MUST NEVER be routed in the same conduit as A C power wires Always consult and follow all local electrical codes 106728 Figure 8 Chain Configuration Normal Drive Figure 7 Service Conduits 106...

Страница 8: ...d in wires need not be in PVC but must have at least six 6 twists per running foot For a saw cut installation observe the method recommended in Figurez10 for the corners When installing a two loop rev...

Страница 9: ...with the operator in place Before inserting the remaining redhead bolts make sure the operator is sitting level If any corners of the operator are resting above the pad slide flat washers under the op...

Страница 10: ...100 OHMS resistance and for more than 100 milliseconds duration Two of the inputs ALTERNATE and RADIO OPEN are momentary inputs where the signal must be released and re entered to be recognized The r...

Страница 11: ...parate from the receiver s output connection This is necessary as the LP1000 control board 24 VAC is isolated from chassis ground A 3 prong receiver CANNOT be installed in association with the LP1000...

Страница 12: ...factory configured for right hand installations If it is installed in a left hand installation make sure the main power switch is off and locate the 8 pin motor wire connector in the upper center of t...

Страница 13: ...limit nut two more slots to give the operator time to stop the gate after the limit switch has been activated Release the detent plate and make sure it drops into the slots on both limit nuts Manually...

Страница 14: ...he test mode the operator control board changes to a sleep mode and a low pulsed tone is heard from the audible output You can reset the operator for a renewed 20 test cycles by turning the power off...

Страница 15: ...rol board of the LP1000 operator See Figure 22 These lights are used to verify proper operation of the LP1000 TURN ON THE MAIN POWER SWITCH Remove the white high voltage connector from the control boa...

Страница 16: ...lots in either direction to fine tune the gate s limits of travel When final adjustment has been completed insure that the detent plate is firmly seated in the slots Review Figure 18 Page 13 SETTING T...

Страница 17: ...operator should respond to an obstruction not encountered by the other the gates will temporarily get out of sync Synchronization will be restored after the next input command cycle D STARTING THE OPE...

Страница 18: ...to terminals 3 or 13 COMMON Multiple devices may be connected in parallel NAME DESCRIPTION 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening directi...

Страница 19: ...19 D STARTING THE OPERATOR Figure 23 Wiring Schematic and Diagram 110146...

Страница 20: ...or Close Contact Sensor input or a Close Overload activation will cause the gate to stop pause and reverse for approximately 2 inches in the Open direction xIf the gate is moving in a Close direction...

Страница 21: ...ollowing safety features x Electric gate edges x Enclosed tracks x Vertical guard posts x Protective screen mesh x Photoelectric sensors x Instructional and precautionary signs x Covers for exposed ro...

Страница 22: ...mpensate for a poorly operating slide gate Correct all mechanical problems on the gate and gate hardware before installing the gate operator Have a qualified service technician make repairs to the gat...

Страница 23: ...r 2 EA not shown 110136 Installation Owner s Manual 1 EA 24b 111886 Box Cover 4 x 2 Duplex Raised 1 EA OPERATOR EXPLODED VIEW 110153 OPERATOR PARTS LIST RISK OF ELECTROCUTION TURN OFF THE MAIN POWER S...

Страница 24: ...purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorization instructions for the return of any goods f...

Отзывы: