The Allstar HDSLG 1000 Vehicular Gate Operator will provide 
convenience and assurance to the ultimate users for many years.  It is 
ruggedly built of the finest materials and has been thoroughly inspected 
and tested at the Allstar factory.  It has many features that will aid in the 
installation and testing of the complete gate system.  The HDSLG has 
been evaluated by Underwriters Laboratory, Inc. (UL) and is certified 
to comply with UL Standard for Safety 325, as evidenced by the UL 
symbol on the name plate.   

Because the HDSLG (as well as gate operators sold by other 

manufactures) is designed to start and move gates weighing as much as 
1200 pounds, or more,---the HDSLG is capable of producing high 
levels of force.  It is important in the design of the total gate system that 
designers, installers and users be aware of the hazards that may be 
associated with the 

IMPROPER

 design, installation and use of 

vehicular gate systems and gate operators. 
The gate operator  is only one part of a complete automatic gate 
operating system.  As each location and usage is different, a properly 
designed system will include all applicable safety devices. 

As the designer and installer

 of the 

GATE SYSTEM

, you must 

advise the purchaser on the proper use of the gate system.  You also 
have the primary responsibility of insuring that 

ALL

 possible 

operational hazards have been considered and eliminated.  

YOU 

MUST ADVISE AND WARN

 the purchaser and the ultimate user of 

ANY HAZARDS

 that you have not been able to eliminate. 

The HDSLG has several features that can help reduce the hazards 
of your gate system.

 

The Allstar HDSLG has a built-in "overload detector" that can help 
reduce the hazards of your gate system.  This device, however, must not 
be considered as the primary obstruction sensing system.  Consider all 
available options (electric leading edges, photoelectric sensors, 
protective screen mesh, etc) to eliminate hazards in your gate system 
design. 
The HDSLG built-in overload detector will activate if there is an abrupt 

increase in motor current above that normally required to move the 
gate.  THE OVERLOAD DETECTION POINT IS AN ADJUSTABLE 
SETTING THAT MUST BE DETERMINED AT THE TIME OF 
INSTALLATION.  THIS SETTING MUST BE TESTED 
PERIODICALLY TO ENSURE PROPER OPERATION.  THE MORE 
FREELY THE GATE WILL MOVE THE MORE SENSITIVE THIS 
SETTING CAN BE MADE.  See Page 17. 

 

ADVISE THE PURCHASER TO CHECK THE SENSITIVITY 

OF THE OVERLOAD PERIODICALLY AND RECORD THE DATE 
TESTED ON THE LOG PROVIDED BELOW  (See Figure 1). 
The HDSLG has a maximum motor current trip mechanism.  If the 
motor current is maintained at or near maximum for a period of 
approximately two seconds the power will be turned off to the motor.  
(This situation could occur if the gate becomes jammed.) 
The HDSLG has a Maximum Run Timer.  If the gate is activated and 
no other command is given or an end limit (open or close) is not 
reached in approximately 45 seconds, the operator will be turned off.  
(See Page 19) 
The HDSLG has an auxiliary “alarm” relay that can be used to give a 
WARNING when the gate is opening or closing or if the OVERLOAD 
has been activated.  TO USE THIS ALARM FEATURE WILL 
REQUIRE THAT THE INSTALLER PROVIDE THE ALARM 
MECHANISM AND THE ELECTRICAL POWER FOR THE 
ALARM.  See Page 17. 

Figure 1 

PRE INSTALLATION NOTES 

NOTICE 

T H E   IM P O R T AN T  SAF E G U AR D S   AN D 
INSTRUCTIONS IN THIS MANUAL  CANNOT 

COVER ALL POSSIBLE CONDITIONS AND SITUATIONS 
WHICH MAY OCCUR DURING ITS USE.  IT MUST BE 
UNDERSTOOD THAT COMMON SENSE AND CAUTION 
MUST BE EXERCISED BY THE PERSON(S) INSTALLING, 
MAINTAINING AND OPERATING THE EQUIPMENT 
DESCRIBED HEREIN.  DO NOT USE THIS EQUIPMENT FOR 
ANY OTHER THAN ITS INTENDED PURPOSE — 
OPERATING A SLIDE GATE. 

 

W A R N I N G   H I G H   V O LTA G E

 

ONLY A QUALIFIED TECHNICIAN SHOULD SERVICE THIS GATE OPERATOR 

 

PERIODICALLY TEST SENSITIVITY OF OVERLOAD 

***  READ MANUAL  *** 

 

DATES 

OPERATOR  

DATE TESTED 

DATE TESTED 

DATE TESTED 

DATE TESTED 

SERVICED 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOG DATE OVERLOAD TEST 

 

NOTICE 

BEFORE ATTEMPTING INSTALLATION, 

 

READ  THIS  MANUAL  CAREFULLY    SO  YOU 

WILL BE THOROUGHLY FAMILIAR WITH THE 
FEATURES OF THE LEADER AND ITS PROPER 
INSTALLATION PROCEDURES. 

 

Содержание HDSLG 1000

Страница 1: ...date of manufacture meets all ANSI UL 325 Safety Requirements for Vehicular gate operators HDSLG 1000 Heavy Duty Vehicular Slide Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE Se...

Страница 2: ...rator Lock 19 Maximum Run Timer 19 Final Setting for Bi Parting Installations 19 Fuses 20 Section E Auxiliary Equipment 20 Section F Safety Guide 21 Operator Exploded View Parts List 23 Technical Spec...

Страница 3: ...LG built in overload detector will activate if there is an abrupt increase in motor current above that normally required to move the gate THE OVERLOAD DETECTION POINT IS AN ADJUSTABLE SETTING THAT MUS...

Страница 4: ...gn to protect system entrapment zones Allstar can provide these products for incorporation in your gate installation CANTILEVERED ROLLER GATES WITH OPEN ROLLERS HAVE THE POTENTIAL HAZARD OF HANDS AND...

Страница 5: ...ct any auxiliary equipment to the operator detectors card readers etc until the gate operator and all its functions are fully tested Only connect one device at a time and ensure its proper function s...

Страница 6: ...ide of the operator Four redhead bolts 3 8 or 1 2 in diameter should be used for mounting the operator The bolt pattern is 10 wide by 16 3 4 long The two rear bolts closest to the gate should be no cl...

Страница 7: ...to determine the correct wire size The NOMINAL column is the ideal distance from the breaker panel to the operator for a given wire size The distances shown in the MAXIMUM column should never be excee...

Страница 8: ...of the slot 8 above the top of the operator pad Attach one end of the chain to the gate and thread the other end through the idler pulleys and drive sprocket Attach the free end to the bracket on the...

Страница 9: ...et failure With the operator properly aligned with the gate drill the remaining three holes with the operator in place Before inserting the remaining redhead bolts make sure the operator is sitting le...

Страница 10: ...lightning strike be shunted to ground This must be done without raising the potential of the circuitry in the operator with respect to ground to the levels that will damage the solid state circuitry L...

Страница 11: ...cturer s instructions Crimp 1 4 quick disconnect lugs to the RELAY COMMON and PRESENCE OUTPUT wires on the detector harness The RELAY COMMON wire is connected to terminal 1 COMMON on the control box 1...

Страница 12: ...ceiver in most cases Many other auxiliary devices such as card readers and key pads using bridge rectifiers require that both sides of the transformer supplying power be floating and not grounded Fail...

Страница 13: ...13 Figure 15 Schematic Wiring Diagram 107788 C INSTALLING THE OPERATOR...

Страница 14: ...vated the gate will not move Gate will move briefly if RADIO or PULSE is activated Gate will run open if HOLD OPEN is activated 7 ALTERNATE Pulsed signal This input is used for COMMAND OPEN COMMAND CL...

Страница 15: ...y connect the receiver For any 4 wire receiver two of the wires will be for power input and two will be for the relay contacts Locate the AUXILIARY Transformer on the Limit Plate Connect the two wires...

Страница 16: ...when more than one COMMON or ground wire is attached between separate operators All accessory equipment should also be wired to the PRIMARY From each of the control inputs with accessory equipment att...

Страница 17: ...TECTION Switch 1 OFF Open Direction The gate will stop move in the close direction for 1 2 second and park Close Direction The gate will stop move in the open direction for 1 2 second and park SWITCH...

Страница 18: ...ed above EXCEPT NOTE that the Open and Close limit switches are REVERSED SETTING THE OBSTRUCTION DETECTION SENSITIVITY T h e operator is equipped with an obstruction detection circuit which will detec...

Страница 19: ...MUM RUN TIMER MRT The control board has a non adjustable maximum run timer circuit The MRT is preset to approximately 45 seconds maximum run time at the factory If the operator initiates an OPEN or CL...

Страница 20: ...close Remove the plate from the loop and observe that the gate closes Some vehicle detectors will tune out a constant obstruction to the loop after 15 to 30 minutes 3 Installing other entry devices Af...

Страница 21: ...n your gate system install the following safety features Electric gate edges Enclosed tracks Vertical guard posts Protective screen mesh Photoelectric sensors Instructional and precautionary signs Cov...

Страница 22: ...be out of reach of the gate so that no one pushing the button or inserting the card is in the path of the gate or moving parts it must also be within INSTALL SAFETY DEVICES In residential application...

Страница 23: ...y Timing Belt 9 54 PD 60 GR 1 ea 20 102832 Cover Control Box HDSLG 1 ea 11 010605 Shaft Lower HDSLG 1 ea 21 102828 Control Box HDSLG 1 ea 12 010198 Bushing Taper Lock 3 4 Bore 1 ea 22 107786 Motor Con...

Страница 24: ...mily home use and two 2 years from the date of purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorizat...

Отзывы: