TOOLS REQUIRED 

 
The following tools and materials are required for proper 
installation of the operator: 
 

 

Two 3/4" wrenches. (For tightening hex nuts on the chain 
take-up bolts.) 

 

2. Chain cutting tool. (For adjusting chain length.) 

 

3. Wire cutter, stripper and crimping tools. (For attaching                        

accessory equipment to the control box barrier strip.) 

 

4. Standard screwdriver. (For junction box face plate.) 

 

5. Very small standard screw driver. (For adjusting 

controller board trimmer potentiometers.) 

6. Phillips head screwdriver. (For control box face plate.) 

The following is a check list of the various parts included with the operator:

 

1. 1 HDSLG 1000 Gate Operator w/Cover 

2.  2  Cover Lock Keys 

3.   

3.  2  Gate Warning Sign 

4. s 

4. 2   Chain Brackets 

5. 1  Chain Take-up Bolt Kit 

6.   

UNPACKING CHECKLIST 

PLACING THE OPERATOR 
 

The recommended procedure for attaching the operator to the concrete 
pad is first to locate and drill the hole for the right rear redhead.  
Review Figure 6, Page 6.  After placing the redhead in the hole, remove 
the cover and lower the operator over the redhead.  Make sure the two 
rear mounting holes on the operator are exactly the same distance from 
the gate.  (Improper alignment of the operator will cause premature 
chain and idler sprocket failure.)  With the operator properly aligned 
with the gate, drill the remaining three holes with the operator in place. 
 
 Before inserting the remaining redhead bolts, make sure the operator is 
sitting level.  If any corners of the operator are resting above the pad, 
slide flat washers under the operator and insert the redhead through the 
washers.  Place the flat washers, lock washers and nuts on the redhead 
bolts and tighten down the operator securely. 
 

 

ELECTRICAL HOOKUP 
 

 
The operator requires a 3-wire, 115 VAC electrical hook-up for proper 
operation.  Ideally, the conduit containing the hook-up wires should exit 
the concrete pad under the operator.  Run flexible conduit from the 
point where the conduit exits the pad and attach it to the bottom of the 
junction box at the front of the frame.  Review Figure 7, Page 7.   
 
If the hook-up exits the pad external to the operator, there's a 7/8" 
diameter hole in each side of the frame near the front of the operator.  
Review Figure 7, Page 7.   
 
Remove the junction box face plate.  Using the wire nuts provided, 
attach the three lead wires to the electrical hook-up wires in the 
following manner: 
 
 
 
1.

The BLACK wire attaches to the 115 VAC HOT wire. 

 

2.

The WHITE wire to the 115 VAC NEUTRAL wire. 

 

3.

The GREEN wire to the GROUND wire. 

 

 

    W A R N I N G !  

RISK OF ELECTROCUTION 

DO NOT BEGIN THE ELECTRICAL CONNECTION 

PROCEDURES UNTIL THE POWER IS TURNED OFF 

AT THE CIRCUIT BREAKER 

C

: INSTALLING THE OPERATOR  

Содержание HDSLG 1000

Страница 1: ...date of manufacture meets all ANSI UL 325 Safety Requirements for Vehicular gate operators HDSLG 1000 Heavy Duty Vehicular Slide Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE Se...

Страница 2: ...rator Lock 19 Maximum Run Timer 19 Final Setting for Bi Parting Installations 19 Fuses 20 Section E Auxiliary Equipment 20 Section F Safety Guide 21 Operator Exploded View Parts List 23 Technical Spec...

Страница 3: ...LG built in overload detector will activate if there is an abrupt increase in motor current above that normally required to move the gate THE OVERLOAD DETECTION POINT IS AN ADJUSTABLE SETTING THAT MUS...

Страница 4: ...gn to protect system entrapment zones Allstar can provide these products for incorporation in your gate installation CANTILEVERED ROLLER GATES WITH OPEN ROLLERS HAVE THE POTENTIAL HAZARD OF HANDS AND...

Страница 5: ...ct any auxiliary equipment to the operator detectors card readers etc until the gate operator and all its functions are fully tested Only connect one device at a time and ensure its proper function s...

Страница 6: ...ide of the operator Four redhead bolts 3 8 or 1 2 in diameter should be used for mounting the operator The bolt pattern is 10 wide by 16 3 4 long The two rear bolts closest to the gate should be no cl...

Страница 7: ...to determine the correct wire size The NOMINAL column is the ideal distance from the breaker panel to the operator for a given wire size The distances shown in the MAXIMUM column should never be excee...

Страница 8: ...of the slot 8 above the top of the operator pad Attach one end of the chain to the gate and thread the other end through the idler pulleys and drive sprocket Attach the free end to the bracket on the...

Страница 9: ...et failure With the operator properly aligned with the gate drill the remaining three holes with the operator in place Before inserting the remaining redhead bolts make sure the operator is sitting le...

Страница 10: ...lightning strike be shunted to ground This must be done without raising the potential of the circuitry in the operator with respect to ground to the levels that will damage the solid state circuitry L...

Страница 11: ...cturer s instructions Crimp 1 4 quick disconnect lugs to the RELAY COMMON and PRESENCE OUTPUT wires on the detector harness The RELAY COMMON wire is connected to terminal 1 COMMON on the control box 1...

Страница 12: ...ceiver in most cases Many other auxiliary devices such as card readers and key pads using bridge rectifiers require that both sides of the transformer supplying power be floating and not grounded Fail...

Страница 13: ...13 Figure 15 Schematic Wiring Diagram 107788 C INSTALLING THE OPERATOR...

Страница 14: ...vated the gate will not move Gate will move briefly if RADIO or PULSE is activated Gate will run open if HOLD OPEN is activated 7 ALTERNATE Pulsed signal This input is used for COMMAND OPEN COMMAND CL...

Страница 15: ...y connect the receiver For any 4 wire receiver two of the wires will be for power input and two will be for the relay contacts Locate the AUXILIARY Transformer on the Limit Plate Connect the two wires...

Страница 16: ...when more than one COMMON or ground wire is attached between separate operators All accessory equipment should also be wired to the PRIMARY From each of the control inputs with accessory equipment att...

Страница 17: ...TECTION Switch 1 OFF Open Direction The gate will stop move in the close direction for 1 2 second and park Close Direction The gate will stop move in the open direction for 1 2 second and park SWITCH...

Страница 18: ...ed above EXCEPT NOTE that the Open and Close limit switches are REVERSED SETTING THE OBSTRUCTION DETECTION SENSITIVITY T h e operator is equipped with an obstruction detection circuit which will detec...

Страница 19: ...MUM RUN TIMER MRT The control board has a non adjustable maximum run timer circuit The MRT is preset to approximately 45 seconds maximum run time at the factory If the operator initiates an OPEN or CL...

Страница 20: ...close Remove the plate from the loop and observe that the gate closes Some vehicle detectors will tune out a constant obstruction to the loop after 15 to 30 minutes 3 Installing other entry devices Af...

Страница 21: ...n your gate system install the following safety features Electric gate edges Enclosed tracks Vertical guard posts Protective screen mesh Photoelectric sensors Instructional and precautionary signs Cov...

Страница 22: ...be out of reach of the gate so that no one pushing the button or inserting the card is in the path of the gate or moving parts it must also be within INSTALL SAFETY DEVICES In residential application...

Страница 23: ...y Timing Belt 9 54 PD 60 GR 1 ea 20 102832 Cover Control Box HDSLG 1 ea 11 010605 Shaft Lower HDSLG 1 ea 21 102828 Control Box HDSLG 1 ea 12 010198 Bushing Taper Lock 3 4 Bore 1 ea 22 107786 Motor Con...

Страница 24: ...mily home use and two 2 years from the date of purchase for multi family and commercial use To obtain service contact your dealer To obtain service under this warranty the buyer must obtain authorizat...

Отзывы: