TO REDUCE THE RISK OF SEVERE 

INJURY OR DEATH: READ AND FOLLOW 

ALL INSTALLATION INSTRUCTIONS AND 

GATE SYSTEM DESIGN PARAMETERS!

 

 

WARNING! 

GATE SYSTEM DESIGN AND INSTALLATION 

SAFETY CHECK LIST: 

 

• 

The GS6000 operator may be installed on a Class I, II, III, or IV 
Vehicular Swing Gate.  See page 3 for an explanation of the 
different Class locations.  See the last page of this manual for the 
operator specifications (voltage, maximum gate weight & length 
etc.). 

• 

Make sure that the gate moves freely, all hinges are in good 
working order, the gate does not bind in any manner and the gate 
swing area is clean and free of irregularities.  DO NOT 
INSTALL THE OPERATOR UNTIL ALL GATE PROBLEMS 
HAVE BEEN CORRECTED. 

• 

Do not increase the built-in overload detector adjustment or 
overtighten the torque limiter to compensate for a poorly 
working gate.  A well maintained gate will ensure easy manual 
operation (if needed) and maximum operator obstruction 
sensitivity. 

• 

Install  the operator on the inside of the property/fence line.  DO 
NOT install an operator on the public side of the fence line or 
gate.  Outward swinging gates should not open into public areas. 

• 

The gate must be installed in a location so that enough clearance 
is supplied between the gate and any adjacent structures when 
opening and closing to reduce the risk of entrapment. 

• 

Make sure the gate operating system is placed far enough back 

from the road to eliminate traffic backup.  The distance from the 

road, size of the gate, usage level and gate cycle/speed must be 

taken into consideration to eliminate potential hazards. 

• 

For ORNAMENTAL “GRILL TYPE” GATES (or any other 
type of open gate where a handhold or toehold may be achieved), 
injuries may occur when people put arms through the openings or 
children “ride” the gate by standing on the bars and holding on to 
the gate.  THIS POTENTIAL HAZARD CAN BE MINIMIZED 
BY INSTALLING A MESH SCREEN ON THE GATE.  Allstar 
strongly recommends the entire gate and adjacent fence area the 
gate covers when open be meshed or guarded such that a 
handhold or toehold cannot be achieved.  See Figure 2. 

• 

All Allstar gate operators are VEHICULAR GATE 
OPERATORS and as such are NOT RECOMMENDED FOR 
PEDESTRIAN traffic.  In installations where pedestrians are 
likely to be nearby,  install a pedestrian gate and use leading 
edge detectors and/or photocells in your design to protect system 
entrapment zones.  Allstar can provide these products for 
incorporation in your design. 

 

• 

Use the illustration at left (Figure 3) to minimize the risk of 

injury in your design of the swing gate operator system.  

IDENTIFY THE ENTRAPMENT ZONES AND PINCH 

POINT AREAS IN YOUR GATE.  Design the gate installation 

to minimize the risk of entrapment in these areas.  Install 

additional safety equipment such as four wire edges and 

photocells to further minimize risk.  All entrapment zones are 

required to be protected. 

 

• 

Entrapment Zones:

  Design in personal entrapment protection 

devices to protect people from entrapment in the zones shown in 

Figure 3 at left.

 

• 

Pinch Points:

  Use protective measures (guards, padded edges, 

etc.) to protect people from the pinch points shown in Figure 3 at 

left.

 

 

Figure 2 

104949 

 

A:

 GATE SYSTEM DESIGN/ INSTALLATION 

PINCH POINTS 

ELECTRIC GATE EDGE 

ENTRAPMENT 

ZONE 

ENTRAPMENT 

ZONE 

104932 

Figure 3 

4  

Содержание Gate Star 6000

Страница 1: ...fety Requirements for Vehicular gate operators GATE STAR 6000 Model GS6000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCT...

Страница 2: ...s throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instruct...

Страница 3: ...is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check out of the GS6000 Connections...

Страница 4: ...n to eliminate potential hazards For ORNAMENTAL GRILL TYPE GATES or any other type of open gate where a handhold or toehold may be achieved injuries may occur when people put arms through the openings...

Страница 5: ...TS AND PULLEYS when the operator cover is removed Apply power to the operator only when instructed to do so When the GS6000 cover is removed high voltage is exposed in the control box area EVEN IF THE...

Страница 6: ...LOOPS If Vehicle Detectors are to be used with the GS6000 the Loops to be buried in the drive should be installed during the site preparation phase of the installation Proper placement of the Vehicle...

Страница 7: ...UST BE HEAT AND WATER RESISTANT CROSS LINK POLYETHYLENE INSULATED TYPE XLPE IS BEST RHW IS O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation...

Страница 8: ...00 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a 230 VAC rated GS6000 CHECK THE OPERATOR PRODUCT LABEL The GS6000 rated for 230 VAC may be ope...

Страница 9: ...with gate and an isometric view of the gate arm assembly in a exploded fashion All dimensions are applicable to either the left hand or right hand views transpose them as necessary to your particular...

Страница 10: ...assembly into the outer through hole on the crank arm see Figure 10 Action C The release handle bolt assembly is inserted such that it points away from the gate Place the 3 8 internal tooth lock washe...

Страница 11: ...l installation the torque limiter adjustment nut is still loosened if resetting use the OPEN CLOSE and STOP buttons to place the operator into position Temporarily immobilize the gate in this FULLY CL...

Страница 12: ...st lightning strikes attempt to enter an appliance through the power lines Effective protection requires that the surge current from the lightning strike be shunted to ground This must be done without...

Страница 13: ...iary equipment devices must be of the type that require both sides of the transformer supplying power be floating and not grounded The GS6000 auxiliary equipment low voltage power terminals 1 2 is not...

Страница 14: ...losing the gate In general two wires or terminals are provided by the device to operate the gate Follow the manufacturers instructions on locating these connections If one of the connections at the de...

Страница 15: ...ng first physically mount the device according to the manufact urer s instructions Follow Figure 16C for connections to the GS6000 terminal strips Ensure the device power is s u p p l i e d separately...

Страница 16: ...s on a limit will prevent operation in that direction Continuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode C...

Страница 17: ...tput mode and could be coupled to and would control a Secondary control board box APPLYING POWER TO THE GS6000 PRE POWER CHECK LIST Before applying power to the GS6000 for the first time go through th...

Страница 18: ...o Terminal 4 Radio Open Radio Open light is ON Motor Open light is ON 6 Remove wire from Terminal 4 Radio Open Radio Open light goes OUT Motor Open light stays ON 7 Connect to Terminal 8 Stop Both Mot...

Страница 19: ...CH LIGHT IS ON TURN OFF THE MAIN POWER SWITCH IF THE GATE HITS THE MECHANICAL LIMIT AND THE LIMIT SWITCH LIGHT DOES NOT COME ON THE LIMIT CAM OR THE STOP WILL NEED TO BE READJUSTED If the gate stops s...

Страница 20: ...E TRY ADJUSTING THE POTENTIOMETERS SEVERAL TIMES BY SMALL INCREMENTS TESTING THE OVERLOAD BY STRIKING THE GATE WITH YOUR PALM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU...

Страница 21: ...DESCRIPTION 10 CLOSE PHOTO CONT Momentary or continuous signal 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening direction it has no effect on the g...

Страница 22: ...ur gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions for mechanical components safety features and the Allstar GS6000 are avail...

Страница 23: ...prevent injury or entrapment Loop detectors may be installed to detect vehicular traffic and prevent vehicular damage MAINTAIN THE GATE AND GATE HARDWARE A damaged gate or one that cannot be easily op...

Страница 24: ...ate to begin moving in the Open direction If the gate is moving in an Open direction an Open Non Contact Sensor Open Contact Sensor input or an Open Overload activation will cause the gate to stop pau...

Страница 25: ...cover Action B Slide the turret cover down the gate arm an appropriate length to complete Actions C D Action C Rotate the release handle 180 degrees away from the gate arm assembly Action D Pull the r...

Страница 26: ...OPERATOR EXPLODED VIEW 26 Figure 24 GS6000 Exploded View 008029 006043 111673 112539 010172 112485...

Страница 27: ...107307 Screw 10 24 x 3 8 HX SL WA T F SS 110132 Receptacle Duplex Outlet Switch 120 VAC 111673 Control Box GS6 HDSWG 111674 Control Box Bottom GS6 HDSWG 111725 Socket Octal 11 Pin DIN Panel Mounting 1...

Страница 28: ...the goods The goods must be returned with complete identification with copy of proof of purchase freight prepaid and in accordance with Allstar s instructions or they will not be accepted In no event...

Отзывы: