Allstar Gate Star 6000 Скачать руководство пользователя страница 27

PART # 

DESCRIPTION 

005068 

CON, 3/8 FLEX Conduit, Straight, AMP 207370-1 

005244 

Transformer, 120V-24V, 50/60 Hz, Class 2, 40VA 

006030 

Screw, 5/16-18 x 1, ZI 

006034 

Nut, 1/2-13, Hex 

006042 

Nut, 4-40, Hex, Captivated Lock Washer 

006043 

Nut, 5/16-18, Hex, Captivated Lock Washer 

006053 

Nut, 6-32, Hex, Captivated Lock Washer 

006044 

Nut, 8-32, Hex, Captivated Lock Washer 

006123 

Screw, 10-24 x 1-1/4, PN PH MA 

006127 

Nut, 10-24, Hex, Captivated Lock Washer 

006140 

Screw, 6-32 x 1, RH MA 

006280 

Nut, 10-32, Hex, SR FL 

008029 

Washer, 3/8, INT TTH Lock, 10T  

010014 

Nut, 5/16-18, U, Tinnerman 

010019 

Screw, 6-32 x 3/4, PH PN MA 

010030 

Screw, 10-32 x 1/2, Hex SL WA 

010037 

Screw, 5/16-18 x 3/4, CR, ZI 

010040 

Screw, 1/2-13 x 1-1/4, HX 

010045 

Screw, 1/4-20 x 1/2, SK, Set 

010056 

Washer, 5/16, INT TTH Lock 

010059 

Washer, 1/2, INT TTH Lock 

010061 

Washer, #10, Flat 

010169 

Connector, Conduit, N, 90 Degree 

010172 

Motor, 1/2HP, 115V, 56, ODP, PSC, GATE, Leeson 

010185 

Grommet, 5/8 ID, for 7/8 Hole 

010213 

Pulley, 2 IN V Belt, 5/8 IN BORE 

010215 

Bearing, PB, 1.25 x 1-11/16TB, CT IR 

010216 

Sprocket, 50B54, 1-1/4 Thru Bore, 1/4 Key 

010217 

Torque Limiter Assembly 

010218 

Speed Reducer, 60:1 

010219 

Pulley, 8”, V-Belt, 5/8 Bore 

010231 

Clutch Disk, Torque Limiter 

010436 

Actuator, Limit Cam 

010651 

Screw, 5/16-18 x 5/8, SQ Head, Set 

100626 

Conduit, Non-Metallic, 1/4 

PART # 

DESCRIPTION 

101490 

Terminal Block, Barrier Type, 11 POS 

103399 

Screw, 10-32 x 3/8, HX SL WA, T/F, Green 

104058 

Washer, 5/16, Flat, SAE 

104450 

Key, 1/4 x 1/4 x 2L 

104479 

Arm Stop,  Heavy Duty SWGO 

105517 

Screw, 8-32 x 1/2, PH RD MA 

105561 

Key, 3/16 x 3/16 x 1 

105574 

Screw, 8-32 x 1/4, PH PN, T/1, S/T 

105575 

Screw, 8-32 x 5/8, PH PN, T/1, S/T 

107307 

Screw, 10-24 x 3/8, HX SL WA, T/F, SS 

110132 

Receptacle, Duplex, Outlet/Switch, 120 VAC 

111673 

Control Box, GS6, HDSWG 

111674 

Control Box Bottom, GS6, HDSWG 

111725 

Socket, Octal, 11 Pin, DIN/Panel Mounting 

111726 

Switch, Push Button, SPST, NO, Black 

111727 

Switch, Push Button, SPST, NO, Red 

111788 

Bracket, AC Cover, High Voltage, GS6 

111789 

Bracket, Panel, Push Buttons, GS6 

111790 

Frame Pan, Loop Socket Mounting, GS6 

111982 

Screw, #10-32 x 3/4, Spade Head, SS 

112032 

Limit Switch, SPDT, Simulated Roller Lever 

112484 

Frame, GS6000, No Components 

112487 

Chain, #40, Roller, Nickel, 65P w/Master Link 

112513 

Belt, V, 4L440, Industrial 

112518 

Motor Control Board, CGO, 120V, GS6, CGA2K 

112524 

Arm, Crank, GS6, 1.25 Diameter Shaft 

112525 

Shaft, Output, GS6, Clevis Pined, 1.25 x 19.36 

112528 

Handle Assy, Release, 3/8-16, GS6 Crank Arm 

112531 

Pin, Ring Grip, 3/8 x 2.3, Quick Release 

112537 

Screw, 4-40 x 1-1/4, PHPM, ZI 

112539 

Washer, #10, Load-Distrib, 0.203 x 0.688 x 0.046 

112540 

Screw, 4-40 x 3/4, PHPM, ZI 

112609 

Wing Nut, 3/8-16 UNC-2B, S/S 

157149 

Standoff, PCB, 3/4IN 

 

 

GATE ARM EXPLODED VIEW AND COMPONENT LIST 

PART # 

DESCRIPTION 

104473 

Arm, Crank Extension, GS6, 1 x 2 x 26.5 

104475 

Fitting, Swing Gate Arm, 1-5/8 x 8 

104476 

Bracket, Swing Gate, 3 x 6 

112549 

Hardware Assy, Swing Arm, GS6000 

112578 

Arm, SWG Gate, Fixed Plate, 1.315 OD x 42L 

GATE ARM COMPONENTS 

104475

104473

112549

104476

112578

Figure 25: GS6000 Arm 
        Components  Exploded  View 

112646 

PART # 

DESCRIPTION 

010291 

Rain Seal Rubber Ring 

104442 

Rain Seal Plate 

104779 

Antenna, Radio Reciever, FC, 10 Inch 

110555 

Receiver, Radio, MVP-1Channel, 318 MHz, 24 VAC 

PART # 

DESCRIPTION 

111805 

Turret Cover,GS6 Swing Gate Arm 

112435 

Access Door Assembly, Cover, GS6 

112536 

Manual, Install / User, GS6000 

112666 

Cover, Operator, Complete w/RainSeal & Access Door 

UNILLUSTRATED  COMPONENT LIST 

PARTS LIST  -  FIGURE 24 - EXPLODED VIEW       

27  

Содержание Gate Star 6000

Страница 1: ...fety Requirements for Vehicular gate operators GATE STAR 6000 Model GS6000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCT...

Страница 2: ...s throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instruct...

Страница 3: ...is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check out of the GS6000 Connections...

Страница 4: ...n to eliminate potential hazards For ORNAMENTAL GRILL TYPE GATES or any other type of open gate where a handhold or toehold may be achieved injuries may occur when people put arms through the openings...

Страница 5: ...TS AND PULLEYS when the operator cover is removed Apply power to the operator only when instructed to do so When the GS6000 cover is removed high voltage is exposed in the control box area EVEN IF THE...

Страница 6: ...LOOPS If Vehicle Detectors are to be used with the GS6000 the Loops to be buried in the drive should be installed during the site preparation phase of the installation Proper placement of the Vehicle...

Страница 7: ...UST BE HEAT AND WATER RESISTANT CROSS LINK POLYETHYLENE INSULATED TYPE XLPE IS BEST RHW IS O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation...

Страница 8: ...00 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a 230 VAC rated GS6000 CHECK THE OPERATOR PRODUCT LABEL The GS6000 rated for 230 VAC may be ope...

Страница 9: ...with gate and an isometric view of the gate arm assembly in a exploded fashion All dimensions are applicable to either the left hand or right hand views transpose them as necessary to your particular...

Страница 10: ...assembly into the outer through hole on the crank arm see Figure 10 Action C The release handle bolt assembly is inserted such that it points away from the gate Place the 3 8 internal tooth lock washe...

Страница 11: ...l installation the torque limiter adjustment nut is still loosened if resetting use the OPEN CLOSE and STOP buttons to place the operator into position Temporarily immobilize the gate in this FULLY CL...

Страница 12: ...st lightning strikes attempt to enter an appliance through the power lines Effective protection requires that the surge current from the lightning strike be shunted to ground This must be done without...

Страница 13: ...iary equipment devices must be of the type that require both sides of the transformer supplying power be floating and not grounded The GS6000 auxiliary equipment low voltage power terminals 1 2 is not...

Страница 14: ...losing the gate In general two wires or terminals are provided by the device to operate the gate Follow the manufacturers instructions on locating these connections If one of the connections at the de...

Страница 15: ...ng first physically mount the device according to the manufact urer s instructions Follow Figure 16C for connections to the GS6000 terminal strips Ensure the device power is s u p p l i e d separately...

Страница 16: ...s on a limit will prevent operation in that direction Continuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode C...

Страница 17: ...tput mode and could be coupled to and would control a Secondary control board box APPLYING POWER TO THE GS6000 PRE POWER CHECK LIST Before applying power to the GS6000 for the first time go through th...

Страница 18: ...o Terminal 4 Radio Open Radio Open light is ON Motor Open light is ON 6 Remove wire from Terminal 4 Radio Open Radio Open light goes OUT Motor Open light stays ON 7 Connect to Terminal 8 Stop Both Mot...

Страница 19: ...CH LIGHT IS ON TURN OFF THE MAIN POWER SWITCH IF THE GATE HITS THE MECHANICAL LIMIT AND THE LIMIT SWITCH LIGHT DOES NOT COME ON THE LIMIT CAM OR THE STOP WILL NEED TO BE READJUSTED If the gate stops s...

Страница 20: ...E TRY ADJUSTING THE POTENTIOMETERS SEVERAL TIMES BY SMALL INCREMENTS TESTING THE OVERLOAD BY STRIKING THE GATE WITH YOUR PALM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU...

Страница 21: ...DESCRIPTION 10 CLOSE PHOTO CONT Momentary or continuous signal 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening direction it has no effect on the g...

Страница 22: ...ur gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions for mechanical components safety features and the Allstar GS6000 are avail...

Страница 23: ...prevent injury or entrapment Loop detectors may be installed to detect vehicular traffic and prevent vehicular damage MAINTAIN THE GATE AND GATE HARDWARE A damaged gate or one that cannot be easily op...

Страница 24: ...ate to begin moving in the Open direction If the gate is moving in an Open direction an Open Non Contact Sensor Open Contact Sensor input or an Open Overload activation will cause the gate to stop pau...

Страница 25: ...cover Action B Slide the turret cover down the gate arm an appropriate length to complete Actions C D Action C Rotate the release handle 180 degrees away from the gate arm assembly Action D Pull the r...

Страница 26: ...OPERATOR EXPLODED VIEW 26 Figure 24 GS6000 Exploded View 008029 006043 111673 112539 010172 112485...

Страница 27: ...107307 Screw 10 24 x 3 8 HX SL WA T F SS 110132 Receptacle Duplex Outlet Switch 120 VAC 111673 Control Box GS6 HDSWG 111674 Control Box Bottom GS6 HDSWG 111725 Socket Octal 11 Pin DIN Panel Mounting 1...

Страница 28: ...the goods The goods must be returned with complete identification with copy of proof of purchase freight prepaid and in accordance with Allstar s instructions or they will not be accepted In no event...

Отзывы: