#  NAME 

DESCRIPTION 

1  24 VAC 

Provides maximum 10 VA auxiliary 
power for accessories. 

2  24 VAC 

Provides maximum 10 VA auxiliary 
power for accessories. 

3  ALTERNATE 

Momentary input, must be released 
and re-entered to be recognized.  

This input is used for “COMMAND OPEN/COMMAND CLOSE” 
applications.  The 1st signal will cause the gate to begin opening.  
A 2nd signal received during the open cycle will stop the gate 
immediately.  A 3rd signal will close the gate.  Connect 
appropriate access control devices to this terminal and #16 
COMMON.  Disable the Close Timer (rotate pot fully counter-
clockwise).  

4  RADIO OPEN 

Momentary input, must be released 
and re-entered to be recognized.  

Once activated the gate will open fully.  Activation while the gate 
is closing will cause it to re-open.   

5  FREE EXIT 

Momentary or continuous input. 

 

Once activated the gate will open fully.  Activation while the gate 
is closing will cause it to re-open.  Continuous activation while the 
gate is open will prevent the Timer-To-Close function from 
automatically closing the gate. 

 

6  OPEN 

Momentary or continuous signal. 
On/Off mode set by Switch #1

 

WITH SWITCH 1 OFF:

 Once activated the gate will open fully.  

Activation while the gate is closing will cause it to re-open.  
Continuous activation while the gate is open will prevent the 
Timer-To-Close function from automatically closing the gate. 
Continuous signal required to move the gate when in the alarm 
mode. 

WITH SWITCH 1 ON:

 Gate does not respond to 

pushbutton input when in the normal mode. Continuous signal 
required to move the gate when in the alarm mode.  

 

7  CLOSE 

Momentary or continuous signal. 
On/Off mode set by Switch #1

 

WITH SWITCH 1 OFF:

 Once activated the gate will close fully.  

Activation while the gate is opening has no effect. Continuous 
signal required to move the gate when in the alarm mode.  

WITH SWITCH 1 ON:

 Gate does not respond to pushbutton input 

when in the normal mode. Continuous signal required to move the 
gate when in the alarm mode.   

 

8  STOP 

Momentary or continuous signal.   

10  CLOSE PHOTO 

Momentary or continuous signal.  

This input is active only when referenced to the closing direction, it 
has no effect on the gate when opening or about to open.  If 
activated when the gate is closing the gate will stop, pause and 
reverse in the open direction for 1/2 second (approx. 2 inches) 
and stop.  Continuous activation will prevent the gate from moving 
in the close direction.  When the input is removed normal 
operation is resumed.  If the Timer-To-Close function initiated the 
close movement and Switch S2 (Re-close)  is ON, the gate will 
automatically re-close from a partially closed position after the 
input to Close Photo is removed. Continuous activation while the 
gate is open will prevent the Timer-To-Close function (if enabled) 
from automatically closing the gate.    

Overrides all other signals.  Once activated, the gate will 
immediately stop and await a new command.  If the STOP input is 
continuously activated, the gate will not move.  

 

#  NAME 

DESCRIPTION 

10  CLOSE PHOTO 

(CONT.) 

Momentary or continuous signal.  

12  OPEN EDGE 

Momentary or continuous signal.   

This input is active only when referenced to the opening direction, it 
has no effect on the gate when closing or about to close.  If activated 
when the gate is opening the gate will stop, pause and reverse in the 
close direction for 1/2 second (approx. 2 inches) and stop. Continuous 
activation will prevent the gate from moving in the open direction.  If a 
second activation occurs before the limit switch is activated the gate 
will stop and a require a renewed, intended input to move in the open 
direction and before an automatic activation device (timer, etc.) will 
operate. This input is intended for Electric Gate Edge systems and 
other minimum-contact devices as appropriate.  Connect here and to 
terminal #16 COMMON.  Multiple devices may be connected in 
parallel.  

13  CLOSE EDGE 

Momentary or continuous signal.  

This input is active only when referenced to the closing direction, it has 
no effect on the gate when opening or about to open.  If activated when 
the gate is closing the gate will stop, pause and reverse in the open 
direction for 1/2 second (approx. 2 inches) and stop.  Continuous 
activation will prevent the gate from moving in the close direction. 
Continuous activation while the gate is open will prevent the Timer-To-
Close function (if enabled) from automatically closing the gate.  If a 
second activation occurs before the limit switch is activated the gate will 
stop and a require a renewed, intended input to move in the close 
direction and before an automatic activation device (timer, etc.) will 
operate. This input is intended for Electric Gate Edge systems and 
other minimum-contact devices as appropriate.  Connect here and to 
terminal #16 COMMON.  Multiple devices may be connected in parallel.  

14  MASTER OPEN 

Momentary or continuous signal.  Master 
(output configuration)  

This terminal is used to coordinate two independent systems (two 
control box/mechanical unit combinations controlling separate gate 
leaves).  Connects to terminal #6 (OPEN) in the companion control box 
and controls the direction of movement in the companion box (Switch 
S3 ON).  

 

15  MASTER CLOSE  Momentary or continuous signal.  Master 

(output configuration)  

This terminal is used to coordinate two independent systems (two 
control box/mechanical unit combinations controlling separate gate 
leaves).  Connects to terminal #7 (CLOSE) in the companion control 
box and controls the direction of movement in the companion box 
(Switch S3 ON).  

 

16  COMMON 

Common connection for low voltage signal 
inputs, terminals 3 through 15. 

This input is intended for photoelectric eye systems and other non-
contact devices as appropriate.  Connect here and to terminal #16 
COMMON.  Multiple devices may be connected in parallel.  

11 

This input is active only when the gate is closing or when it’s fully open 
and the Close Timer is operative.  All stand-alone vehicle detectors, 
photo-eyes and active edges should be connected here and to 
terminals #16 COMMON.  Multiple devices may be connected in 
parallel.  

REVERSE 

Momentary or continuous signal.  

 TERMINAL STRIP REFERENCE CHART 

D: 

STARTING THE OPERATOR - Terminal Strip Chart 

21  

Содержание Gate Star 6000

Страница 1: ...fety Requirements for Vehicular gate operators GATE STAR 6000 Model GS6000 Heavy Duty Commercial Vehicular Swing Gate Operator READ THIS MANUAL CAREFULLY BEFORE INSTALLATION OR USE SAVE THESE INSTRUCT...

Страница 2: ...s throughout this manual are there to protect you and your equipment Pay close attention to these boxes as you follow the manual WARNING Indicates a MECHANICAL hazard of INJURY OR DEATH Gives instruct...

Страница 3: ...is activated before the Torque Limiter slips will depend upon the tightness of the adjustment of the Torque Limiter This adjustment will be explained in the final check out of the GS6000 Connections...

Страница 4: ...n to eliminate potential hazards For ORNAMENTAL GRILL TYPE GATES or any other type of open gate where a handhold or toehold may be achieved injuries may occur when people put arms through the openings...

Страница 5: ...TS AND PULLEYS when the operator cover is removed Apply power to the operator only when instructed to do so When the GS6000 cover is removed high voltage is exposed in the control box area EVEN IF THE...

Страница 6: ...LOOPS If Vehicle Detectors are to be used with the GS6000 the Loops to be buried in the drive should be installed during the site preparation phase of the installation Proper placement of the Vehicle...

Страница 7: ...UST BE HEAT AND WATER RESISTANT CROSS LINK POLYETHYLENE INSULATED TYPE XLPE IS BEST RHW IS O K DO NOT USE ANY PVC INSULATED WIRE PVC insulation will absorb moisture that may affect Detector operation...

Страница 8: ...00 VOLT AMPERE WATT TRANSFORMER MUST BE USED Operating from a three 3 phase line will require the use of a 230 VAC rated GS6000 CHECK THE OPERATOR PRODUCT LABEL The GS6000 rated for 230 VAC may be ope...

Страница 9: ...with gate and an isometric view of the gate arm assembly in a exploded fashion All dimensions are applicable to either the left hand or right hand views transpose them as necessary to your particular...

Страница 10: ...assembly into the outer through hole on the crank arm see Figure 10 Action C The release handle bolt assembly is inserted such that it points away from the gate Place the 3 8 internal tooth lock washe...

Страница 11: ...l installation the torque limiter adjustment nut is still loosened if resetting use the OPEN CLOSE and STOP buttons to place the operator into position Temporarily immobilize the gate in this FULLY CL...

Страница 12: ...st lightning strikes attempt to enter an appliance through the power lines Effective protection requires that the surge current from the lightning strike be shunted to ground This must be done without...

Страница 13: ...iary equipment devices must be of the type that require both sides of the transformer supplying power be floating and not grounded The GS6000 auxiliary equipment low voltage power terminals 1 2 is not...

Страница 14: ...losing the gate In general two wires or terminals are provided by the device to operate the gate Follow the manufacturers instructions on locating these connections If one of the connections at the de...

Страница 15: ...ng first physically mount the device according to the manufact urer s instructions Follow Figure 16C for connections to the GS6000 terminal strips Ensure the device power is s u p p l i e d separately...

Страница 16: ...s on a limit will prevent operation in that direction Continuous signal required to move the gate when in the alarm mode SWITCH 1 ON Gate does not respond to pushbutton input when in the normal mode C...

Страница 17: ...tput mode and could be coupled to and would control a Secondary control board box APPLYING POWER TO THE GS6000 PRE POWER CHECK LIST Before applying power to the GS6000 for the first time go through th...

Страница 18: ...o Terminal 4 Radio Open Radio Open light is ON Motor Open light is ON 6 Remove wire from Terminal 4 Radio Open Radio Open light goes OUT Motor Open light stays ON 7 Connect to Terminal 8 Stop Both Mot...

Страница 19: ...CH LIGHT IS ON TURN OFF THE MAIN POWER SWITCH IF THE GATE HITS THE MECHANICAL LIMIT AND THE LIMIT SWITCH LIGHT DOES NOT COME ON THE LIMIT CAM OR THE STOP WILL NEED TO BE READJUSTED If the gate stops s...

Страница 20: ...E TRY ADJUSTING THE POTENTIOMETERS SEVERAL TIMES BY SMALL INCREMENTS TESTING THE OVERLOAD BY STRIKING THE GATE WITH YOUR PALM IN BOTH DIRECTIONS OF TRAVEL REPEAT THIS TEST UNTIL YOU ARE SATISFIED YOU...

Страница 21: ...DESCRIPTION 10 CLOSE PHOTO CONT Momentary or continuous signal 12 OPEN EDGE Momentary or continuous signal This input is active only when referenced to the opening direction it has no effect on the g...

Страница 22: ...ur gate system Read and follow all instructions for each of the components of your unique system Ensure that all instructions for mechanical components safety features and the Allstar GS6000 are avail...

Страница 23: ...prevent injury or entrapment Loop detectors may be installed to detect vehicular traffic and prevent vehicular damage MAINTAIN THE GATE AND GATE HARDWARE A damaged gate or one that cannot be easily op...

Страница 24: ...ate to begin moving in the Open direction If the gate is moving in an Open direction an Open Non Contact Sensor Open Contact Sensor input or an Open Overload activation will cause the gate to stop pau...

Страница 25: ...cover Action B Slide the turret cover down the gate arm an appropriate length to complete Actions C D Action C Rotate the release handle 180 degrees away from the gate arm assembly Action D Pull the r...

Страница 26: ...OPERATOR EXPLODED VIEW 26 Figure 24 GS6000 Exploded View 008029 006043 111673 112539 010172 112485...

Страница 27: ...107307 Screw 10 24 x 3 8 HX SL WA T F SS 110132 Receptacle Duplex Outlet Switch 120 VAC 111673 Control Box GS6 HDSWG 111674 Control Box Bottom GS6 HDSWG 111725 Socket Octal 11 Pin DIN Panel Mounting 1...

Страница 28: ...the goods The goods must be returned with complete identification with copy of proof of purchase freight prepaid and in accordance with Allstar s instructions or they will not be accepted In no event...

Отзывы: