14/24
6-1622420 rev. 1 21/12/2018
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
UP
DOWN
MENU
SS
ENG
ITA
ENG
FRA
ESP
9.
The MOTOR 1 moves automatically in closing, at running speed.
When the automation reaches the position for the beginning of the slowdown,
give a Step-by-Step command (SS).
In this phase the display shows
LCL
.
10.
The MOTOR 1 proceeds at slowdown speed.
Reached the closing mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LCL
.
11.
The MOTOR 1 moves automatically in opening, at running speed.
When the automation reaches the position for the beginning of the slowdown,
give a Step-by-Step command (SS).
In this phase the display shows
LOP
.
12.
The MOTOR 1 proceeds at slowdown speed.
Reached the opening mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LOP
.
13.
The MOTOR 2 moves automatically in opening, at running speed.
When the automation reaches the position for the beginning of the slowdown,
give a Step-by-Step command (SS).
In this phase the display shows
LOP
.
14.
The MOTOR 2 proceeds at slowdown speed.
Reached the opening mechanical stop, the motor stops automatically.
WARNING - if the motor doesn’t stop automatically, press the “SS”
button.
In this phase the display shows
LOP
.
15.
The automation moves in closing with the second wing delay set into the menu
dLY
and with the slowdowns set.
WARNING - in the event of a safety device intervention, the learning is stopped and will appear on the display
L--
.
Press the “SS” button to start again the learning from the 4th point.
NOTE - if the motors don’t stop automatically during the learning, increase the value of the obstacle sensitivity and /or the obstacle sensitivity during
slowdowns (menu
SEN
and
SEL
), see paragraph 8, and check that the intervention mode of the current sensor is suitable for the use as limit switch
(menu
Sn
.
M
.), see paragraph 9.
Содержание BIOS2 24V
Страница 1: ...MADE IN ITALY BIOS2 24V CENTRALINA PER CANCELLI A BATTENTE 24V...
Страница 25: ...MADE IN ITALY BIOS2 24V CONTROL UNIT FOR WING GATES AT 24V...
Страница 49: ...MADE IN ITALY BIOS2 24V CENTRAL DE COMMANDE POUR PORTAIL BATTANT 24V...
Страница 73: ...MADE IN ITALY BIOS2 24V CUADRO DE MANDO PARA CANCELAS A HOJA 24V...