English - 25 / 36
6-1622396 - rev. 3 - 21/09/2021
PARAMETER
DESCRIPTION
DEFAULT
CUSTOM
MIN
MAX
UM
5
SPNo
Speed when fully operational during opening.
100
50
100
%
6
SPNc
Speed when fully operational during closing.
100
50
100
%
7
SPLo
Slow-down speed during opening.
30
10
100
%
8
SPLc
Slow-down speed during closing.
30
10
100
%
9
sbs
SS configuration:
0 = normal (AP-ST-CH-ST-AP-ST…).
1 = alternated with STOP (AP-ST-CH-AP-ST-CH…).
2 = alternated (AP-CH-AP-CH…).
0
0
2
10
blt
Behaviour after blackout:
0 = no action.
1 = performs opening movement.
2 = performs closing movement.
0
0
2
11
LSIo
Amplitude slowing in opening.
%100…0 = percentage of the ride.
25
0
100
%
12
LSIc
Amplitude slowing in closing.
%100…0 = percentage of the ride.
25
0
100
%
13
asL
Antiskid / Extra-time run.
15
0
300
s
14
ENC
How to use the encoder:
0 = not used
1 = Detect obstacle and position
2 = Detect obstacle
3 = Detect position
3
0
3
1. TIME FOR AUTOMATIC CLOSING
tCL
(0 – 900 seconds) default = 0
It activates at a steady automation in the total opening position, the automation closes after waiting for the
tCL
time. At this stage
the display shows
-tc
with the dash flashing, which in the last ten seconds is replaced by the countdown. An opening command
or photocell intervention restarts the count.
2. TIME FOR AUTOMATIC CLOSING AFTER TRANSIT
ttr
(0 – 30 seconds) default = 0
If during the opening or during the opening permanence the beam of the photocells has been obscured and then released, the
automation closes after having waited the time
ttr
once reached the total opening position. At this stage the display shows
-tc
with the dash flashing, which in the last ten seconds is replaced by the countdown.
3. SENSIVITY ON OBSTACLE AT FULL SPEED
SEn
(0 – 100 %) default = 40%
Adjust the sensitivity on obstacle in order to obtain a proper functioning of the automation, intervening in case of obstacle but
such as to ensure the movement even in the worst operating conditions (e.g. winter, hardening of motors due to wear, etc.). It is
recommended after adjusting the parameter to perform a full movement of opening and closing, before checking the intervention
on obstacle. Lower values correspond to a greater thrust on the obstacle.
Содержание 12007336
Страница 15: ...Italiano 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Страница 51: ...English 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Страница 87: ...Fran ais 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Страница 123: ...Espa ol 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...
Страница 159: ...Nederlandse 15 36 6 1622396 rev 3 21 09 2021 45 45 1 2 3 1 2 3 FIG 27 FIG 28...