53
444h
12 00 A0
2D
Unit Directory
448h
13 00 01
02
44Ch
D4
00
00
01
The entry with key D4 in the unit directory (44Ch in this case) provides the offset for
unit dependent info:
44Ch + 000001 * 4 = 450h
Offset
0-7
8-15
16-23
24-31
450h 00 03 7F
A9
454h
40
3C
00
00
Unit Dependent Info
458h
81 00 00
02
45Ch
82
00
00
06
And finally, the entry with key 40 (454h in this case) provides the offset for the camera
control register:
FFFF F00 3C0000h * 4 = FFFF F0F00000h
The base address of the camera control register is thus
FFFF F0F00000h.
The offset entered in the table always refers to the base address of F0F00000h.
L
This means that if you want to use the “DirectControl” program to read or write to a
register, the following value must be entered in the
Address
field:
“F0F Offset”
The following example should make this clear:
The camera has a temperature sensor. It measures the temperature and can be output at
any time in 0.1°C increments. The register with offset 82Ch is available for this. The
“Directcontrol” program can be used to read from this register.