x330-10GTX Gigabit Ethernet Switch Installation Guide
75
2. Connect the other end of the cable to an RS-232 port on a terminal or
personal computer with a terminal emulation program.
3. Configure the VT-100 terminal or terminal emulation program as
follows:
Baud rate: 115200 bps
Data bits: 8
Parity: None
Stop bits: 1
Flow controller: None
Note
The port settings are for a DEC VT100 or ANSI terminal, or an
equivalent terminal emulator program.
4. Press Enter. You are prompted for a user name and password.
5. Enter the default user name and password. They are “manager” and
“friend” (without the quotes), respectively
Note
User names and passwords are case sensitive.
The local management session starts when the User Exec mode
prompt, shown in Figure 41. is displayed.
Figure 41. User Exec Mode Prompt
Note
The User Exec mode is the first level in the command mode
interface. For information on the modes and commands, refer to the
x330 Series Software Reference for AlliedWare Plus Operating
System
from
www.alliedtelesis.com
.
6. Go to “Verifying the Switch” on page 76.
awplus>
Содержание x330-10GTX
Страница 1: ...613 002996 Rev A x330 10GTX Gigabit Layer 3 Ethernet Switch Installation Guide...
Страница 6: ...6...
Страница 10: ...Figures 10...
Страница 12: ...Tables 12...
Страница 16: ...Preface 16...
Страница 36: ...Chapter 1 Overview 36...
Страница 48: ...Chapter 2 Beginning the Installation 48...
Страница 82: ...Chapter 6 Cabling the Networking Ports 82 Figure 46 Connecting a Fiber Optic Cable to an SFP or SFP Transceiver...
Страница 88: ...Chapter 7 Troubleshooting 88...
Страница 98: ...Appendix A Technical Specifications 98...