Chapter 7: Troubleshooting

86

Verify that the cable does not exceed 100 meters (328 feet).

Verify that you are using the appropriate category of cable. Cable 
requirements are listed in Table 1 on page 22 and Table 2 on 
page 24.

Verify that the port is connected to the correct cable.

Note

Copper ports may require up to five to ten seconds to establish links 
to network devices.

Problem 3:

 The link/activity LED for the SFP+ port is off.

Solutions:

 The transceiver in the SFP+ port has not established a link to a 

network device. Try the following:

Verify that the remote network device connected to the fiber optic 
port is operating properly.

Verify that the fiber optic cable is securely connected to the port on 
the transceiver and to the port on the remote network device.

Check that the transceiver is fully inserted in the port in the switch.

Verify that the operating specifications of the fiber optic ports on 
the transceiver and remote network device are compatible by 
referring to their documentation.

Verify that the correct type of fiber optic cabling is being used.

Verify that the port is connected to the correct fiber optic cable.

Try connecting another network device to the fiber optic port using 
a different cable. If the port can establish a link, then the problem is 
with the cable or with the other network device.

Use the switch’s management software to verify that the port is 
enabled.

If the remote network device is a managed device, use its 
management firmware to determine whether its port is enabled.

Test the attenuation on both directions on the fiber optic cable with 
a fiber optic tester to determine whether the optical signal is too 
weak (sensitivity) or too strong (maximum input power).

Verify that the x330-10GTX switch supports the transceiver by 
referring to its data sheet.

Problem 4: 

The switch functions intermittently.

Solutions:

 Check the system hardware status through the management 

software:

Use the SHOW SYSTEM ENVIRONMENT command in the 
Privileged Exec mode to verify that the input voltage from the 

Содержание x330-10GTX

Страница 1: ...613 002996 Rev A x330 10GTX Gigabit Layer 3 Ethernet Switch Installation Guide...

Страница 2: ...ir respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided here...

Страница 3: ...Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Note Modifications or...

Страница 4: ...35 Laser Safety EN 60825 1 EN 55032 Class A EN 61000 3 2 EN 61000 3 3 India TEC Telecommunications Engineering Center Japan VCCI Class A Voluntary Control Council for Interference Mexico NOM Normas Of...

Страница 5: ...nslated Safety Statements document at www alliedtelesis com us en documents translated safety statements Remarque Les consignes de s curit portant le symbole sont traduites dans plusieurs langues dans...

Страница 6: ...6...

Страница 7: ...1 10Gbps SFP Port LED 28 eco friendly Button 30 Switch ID LED 31 USB Port 33 Console Port 34 Power Supply 35 Chapter 2 Beginning the Installation 37 Reviewing Safety Precautions 38 Choosing a Site for...

Страница 8: ...s SFP or 10Gbps SFP Transceiver 80 Installing an SP10TW Direct Connect Twinax Cable in the SFP Port 83 Chapter 7 Troubleshooting 85 Appendix A Technical Specifications 89 Physical Specifications 90 En...

Страница 9: ...k 58 Figure 24 BRKT J23 Bracket Kit 60 Figure 25 x330 10GTX Switch Wall Installations with Two BRKT J23 Brackets 60 Figure 26 x330 10GTX Switch Wall Installations with Four BRKT J23 Brackets 61 Figure...

Страница 10: ...Figures 10...

Страница 11: ...er Ports 27 Table 6 Link Activity LEDs on the 1 2 5 5 10Gbps Copper Port 28 Table 7 Link Activity LED for the 1 10Gbps SFP Port 29 Table 8 Product Dimensions 90 Table 9 Product Weight 91 Table 10 Vent...

Страница 12: ...Tables 12...

Страница 13: ...is guide contains the installation instructions for the x330 10GTX Layer 3 Gigabit Ethernet switch This preface contains the following sections Document Conventions on page 14 Contacting Allied Telesi...

Страница 14: ...tions Note Notes provide additional information Caution Cautions inform you that performing or omitting a specific action may result in equipment damage or loss of data Warning Warnings inform you tha...

Страница 15: ...r questions in our knowledge database check support tickets learn about Return Merchandise Authorizations RMAs and contact Allied Telesis technical experts Software Downloads Download the latest softw...

Страница 16: ...Preface 16...

Страница 17: ...n page 18 Features on page 19 10 100 1000Mbps Ethernet Copper Ports on page 22 1 2 5 5 10Gbps Ethernet Copper Port on page 24 SFP Port on page 25 Port LEDs on page 26 eco friendly Button on page 30 Sw...

Страница 18: ...tch Figure 1 Front Panel Figure 2 illustrates the back panel Figure 2 Back Panel A Eight10 100 1000Mbps Ethernet Copper Ports B One 1 2 5 5 10Gbps Ethernet Copper Port C One SFP Transceiver Port D One...

Страница 19: ...et Copper Port The 1 2 5 5 10Gbps copper port has these basic features 1000Base T 2 5GBase T 5GBase T and 10GBase T compliant IEEE 802 3bz for 2 5GBase T and 5GBase T Auto Negotiation for speed 100 me...

Страница 20: ...P port Switch ID number LED Note Refer to Port LEDs on page 26 Installation Options Here are the installation options for the switches Desk or tabletop Standard 19 inch equipment rack Wall MAC Address...

Страница 21: ...itches Local management through the Console port Remote Telnet and Secure Shell management Remote HTTP and HTTPS web browser management SNMPv1 v2c and v3 Energy Savings Here are energy saving features...

Страница 22: ...at 10 100Mbps Full duplex mode only at 1000Mbps Duplex modes are set manually or with IEEE 802 3u Auto Negotiation Speed and duplex mode settings of copper ports can be set independently of each othe...

Страница 23: ...support Auto Negotiation Otherwise a speed or duplex mode mismatch might occur between the devices resulting in reduced performance For copper ports connected to devices that do not support Auto Negot...

Страница 24: ...EEE 802 3bz 10Gbps IEEE 802 3an You can set port speed with Auto Negotiation or manually Guidelines are given here 1Gbps and 10Gbps can be set either manually or with Auto Negotiation 2 5Gbps and 5Gbp...

Страница 25: ...ceiver style connectors You can use the port to connect the switch to other network devices over large distances build a high speed backbone network between network devices or connect a high speed dev...

Страница 26: ...1000Mbps Copper Ports Table 3 and Table 4 on page 27 define the LEDs Table 3 Link Activity LEDs on the 10 100 1000Mbps Copper Ports State Description Solid Green The port has established a 1Gbps link...

Страница 27: ...ith another network device The LEDs are turned off To turn on the LEDs use the eco friendly button Table 4 Duplex Mode LEDs on the 10 100 1000Mbps Copper Ports State Description Solid Green The port i...

Страница 28: ...tion Solid Green The port has established a 2 5Gbps 5Gbps or 10Gbps link to a network device Flashing Green The port is transmitting or receiving data at 2 5Gbps 5Gbps or 10Gbps Solid Amber The port h...

Страница 29: ...k device Flashing Amber The port is transmitting or receiving data at 1Gbps Solid Green The port has established at 2 5 5 10Gbps link to a network device Flashing Green The port is transmitting or rec...

Страница 30: ...ack It is the FINDME command The command works on the switch even if you turned off the LEDs with the eco friendly button or NO ECOFRIENDLY LED command The Switch ID LED is always on but it displays d...

Страница 31: ...ich is enabled or disabled with the eco friendly button Refer to eco friendly Button on page 30 The states of the LED when low power mode is disabled are shown in Figure 7 on page 31 Figure 7 Switch I...

Страница 32: ...The states of the LED when low power mode is enabled are shown in Figure 8 Figure 8 Switch ID LED With Low Power Mode Enabled The switch is the master switch of a VCStack The switch is a standalone u...

Страница 33: ...use the port to store configuration files on flash drives or to restore configuration files to the switch if its settings are lost or corrupted or to quickly configure replacement units You may also...

Страница 34: ...device To establish a local management session with the switch you have to connect a terminal or a personal computer with a terminal emulation program to the Console port which has an RJ 45 style 8P8...

Страница 35: ...EE 802 3az Energy Efficient Ethernet EEE EEE is an energy saving feature that reduces power consumption during periods of no data activity The switch saves electricity by placing the Ethernet circuitr...

Страница 36: ...Chapter 1 Overview 36...

Страница 37: ...on The chapter contains the following sections Reviewing Safety Precautions on page 38 Choosing a Site for the Switch on page 42 Unpacking the Switch on page 44 Installation Options on page 45 Install...

Страница 38: ...isponible l adresse www alliedtelesis com en documents translated safety statements Warning Class 1 Laser product L1 Warning Do not stare into the laser beam L2 Warning Do not look directly at the fib...

Страница 39: ...n Air vents must not be blocked and must have free access to the room ambient air for cooling E6 Warning Operating Temperatures This product is designed for a maximum ambient temperature of 50 degrees...

Страница 40: ...ommends that you get assistance when mounting the chassis in an equipment rack E28 Note If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment m...

Страница 41: ...the switch to disable the VCStack feature Some network traffic may be lost if the device is already connected to a live network E75 Warning Switches should not be stacked on top of one another on a t...

Страница 42: ...the port LEDs The x330 10GTX switch does not have cooling fans The site must provide adequate air flow around the unit for cooling Do not install the switch in a wiring or utility box without adequate...

Страница 43: ...l paint color mounting method wall pole ground etc and sun load The smaller enclosure size you choose the higher the risk of overheating the product faces Note If the product overheats in an enclosure...

Страница 44: ...Note If any item is missing or damaged contact your Allied Telesis sales representative for assistance Note Please retain the original packaging material in the event you need to return the unit to A...

Страница 45: ...ion options for the x330 10GTX switch Figure 10 Installation Options for the x330 10GTX Switch Table or desktop with the bumper feet shipped with the switch Standard 19 inch equipment rack with RKMT J...

Страница 46: ...Switch on page 42 Do not stack switches on a table Do not install the switch upside down on a table Do not install the switch vertically on a table Figure 12 Unsupported Table Installations Warning Sw...

Страница 47: ...e accessory kit came with all the appropriate items Refer to Unpacking the Switch on page 44 4 Lift the switch from the shipping box and place it upside down on the table 5 Attach the four bumper feet...

Страница 48: ...Chapter 2 Beginning the Installation 48...

Страница 49: ...ack The instructions in this chapter explain how to install the x330 10GTX switch in a standard 19 inch equipment rack with the optional RKMT J05 equipment rack brackets kit Here are the sections Intr...

Страница 50: ...equipment rack requires the optional RKMT J05 equipment rack brackets kit The brackets allow you to install the switch with the front panel flush with the front of the equipment rack or with the swit...

Страница 51: ...RKMT J05 bracket kit includes two cable trays and ten tie wraps for physically securing the power cord or network cables Refer to Figure 15 Figure 15 x330 10GTX Switch with RKMT J05 Cable Trays Note...

Страница 52: ...52 Figure 16 illustrates the items in the RKMT J05 brackets kit Figure 16 Items in the RKMT J05 Equipment Rack Brackets Kit Two short brackets Two long brackets Two cable trays Two handles Eight M3x6m...

Страница 53: ...s kit sold separately Phillips head screwdriver not provided Four standard equipment rack screws not provided If the bumper feet are installed on the bottom panel of the switch perform steps 1 and 2 t...

Страница 54: ...oving the Feet from the x330 10GTX Switch 3 Attach the handles in the RKMT J05 kit to the short brackets using the supplied M3x6mm pan head screws and a Phillips head screwdriver Be sure to attach the...

Страница 55: ...thernet Switch Installation Guide 55 4 Attach the short brackets to the long brackets using the supplied M4x6mm counter sunk screws Refer to Figure 20 Figure 20 Attaching the Short RKMT J05 Brackets t...

Страница 56: ...ling the x330 10GTX Switch in an Equipment Rack 56 5 Attach one or both cord trays to the long brackets The cord trays are optional Refer to Figure 21 Figure 21 Attaching the RKMT J05 Cord Trays to th...

Страница 57: ...it Ethernet Switch Installation Guide 57 6 Attach the brackets to the bottom panel of the switch Refer to Figure 22 Figure 22 Attaching the RKMT J05 Brackets to the Switch 7 Turn the switch right side...

Страница 58: ...8 Have another person hold the switch in the equipment rack while you secure it with four standard equipment rack screws not provided Refer to Figure 23 Figure 23 Attaching the x330 10GTX Switch to a...

Страница 59: ...Installing the x330 10GTX Switch on a Wall The procedures in this chapter are listed here Introduction on page 60 Installation Guidelines on page 62 Tools and Material on page 63 Installing the Switc...

Страница 60: ...it contains two identical brackets Refer to Figure 24 Figure 24 BRKT J23 Bracket Kit Note The BRKT J23 bracket kit is sold separately You can install the switch with the front panel facing up left or...

Страница 61: ...ure 26 shows the switch with four brackets Figure 26 x330 10GTX Switch Wall Installations with Four BRKT J23 Brackets Do not install the switch with the front panel facing down Refer to Figure 27 Figu...

Страница 62: ...ires two BRKT J23 bracket kits The BRKT J23 bracket kit does not include screws or wall anchors You can install the switch on a wooden or concrete wall The diameter of the screw holes in the brackets...

Страница 63: ...provided Stud finder for a wooden wall capable of identifying the middle of wall studs and hot electrical wiring not provided Depending on the wall material these items might also be required Drill f...

Страница 64: ...the wall If this is true for your installation perform the procedures in Chapter 5 Verifying the Switch on page 69 and Chapter 6 Cabling the Networking Ports on page 77 before performing this procedu...

Страница 65: ...x330 10GTX Gigabit Ethernet Switch Installation Guide 65 Figure 28 Marking the Screw Holes for Two BRKT J23 Brackets Figure 29 Marking the Screw Holes for Four BRKT J23 Brackets...

Страница 66: ...f required pre drill the screw holes on the wall For a concrete wall observe the following Set the drill to hammer and rotation mode to break up the concrete and clean out the hole Clean out the holes...

Страница 67: ...3 brackets Refer to Figure 31 Figure 31 Sliding the Switch into the BRKT J23 Brackets Note If you are installing the switch with two brackets skip the next step and go to Chapter 5 Verifying the Switc...

Страница 68: ...x330 10GTX Switch on a Wall 68 11 Attach the two top brackets to the wall with appropriate screws Refer to Figure 32 Figure 32 Attaching the Top BRKT J23 Brackets to the Wall 12 Go to Chapter 5 Verify...

Страница 69: ...69 Chapter 5 Verifying the Switch This chapter contains the following procedures Powering On the Switch on page 70 Starting a Local Management Session on page 73 Verifying the Switch on page 76...

Страница 70: ...utes to initialize its operating software It does not forward network traffic until after it has completed the initialization process You can monitor the initialization process by connecting a termina...

Страница 71: ...Power Cord 3 Lower the power cord retaining clip to secure the cord to the switch Refer to Figure 35 Figure 35 Lowering the Power Cord Retaining Clip 4 Connect the power cord to an appropriate AC powe...

Страница 72: ...can power cord Your power cord may be different 5 Wait two minutes for the switch to initialize the management software 6 To verify hardware operations begin with Starting a Local Management Session o...

Страница 73: ...DHCPv4 and DHCPv6 clients The default setting for the clients is enabled If the switch does not receive a response to its queries for an IP address it uses the default IPv4 address 169 254 42 42 16 Lo...

Страница 74: ...t3 Management Cable and Switch The following procedure explains how to start a local management session on the switch For instructions on how to start a remote management session refer to the x330 Ser...

Страница 75: ...or program 4 Press Enter You are prompted for a user name and password 5 Enter the default user name and password They are manager and friend without the quotes respectively Note User names and passwo...

Страница 76: ...hooting on page 85 For more information refer to Switch ID LED on page 31 Figure 42 Verifying the Switch ID LED 2 Start a local or remote management session on the switch Refer to Starting a Local Man...

Страница 77: ...ontains the following sections Cabling Copper Ports on page 78 Guidelines to Handling SFP and SFP Transceivers on page 79 Installing 1Gbps SFP or 10Gbps SFP Transceiver on page 80 Installing an SP10TW...

Страница 78: ...ctors into place The default speed setting for the ports is Auto Negotiation This setting is appropriate for ports connected to network devices that also support Auto Negotiation Ports must be set to...

Страница 79: ...nts of the transceivers are provided in documents included with the devices You should install a transceiver before connecting its fiber optic cable Fiber optic transceivers are dust sensitive Always...

Страница 80: ...fferent To install transceivers perform the following procedure 1 Remove the transceiver from its shipping container and store the packaging material in a safe location 2 Position the transceiver with...

Страница 81: ...Verify the position of the handle on the transceiver The handle should be in the upright position as shown in Figure 45 Figure 45 Positioning the SFP Handle in the Upright Position 6 Connect the fiber...

Страница 82: ...Chapter 6 Cabling the Networking Ports 82 Figure 46 Connecting a Fiber Optic Cable to an SFP or SFP Transceiver...

Страница 83: ...s connections over short distances They have SFP transceivers on both ends and come in lengths of one and three meters Note The switch does not support the seven meter SP10TW7 cable To install an SP10...

Страница 84: ...into the port until it clicks into place 4 Connect the other end of the cable into an SFP port on another network device Note To remove the connector and cable from the port gently push on the connect...

Страница 85: ...is within the required levels for your region The power requirements for the switch are listed in Power Specifications on page 93 The switch might be operating in the low power mode To toggle on the...

Страница 86: ...ansceiver and remote network device are compatible by referring to their documentation Verify that the correct type of fiber optic cabling is being used Verify that the port is connected to the correc...

Страница 87: ...oltage fluctuates above or below the approved operating range Verify that the location of the switch allows for adequate airflow The unit will shut down if it overheats Problem 5 The Switch ID LED on...

Страница 88: ...Chapter 7 Troubleshooting 88...

Страница 89: ...contains the following sections Physical Specifications on page 90 Environmental Specifications on page 92 Power Specifications on page 93 Certifications on page 94 RJ 45 Copper Port Pinouts on page 9...

Страница 90: ...ations Dimensions W x D x H Table 7 lists the dimensions of the switch Figure 48 x330 10GTX Switch Dimensions Table 7 Product Dimensions x330 10GTX 263 x 179 x 38 mm 10 35 x 7 04 x 1 497 0 in 263 mm 1...

Страница 91: ...le 8 lists the weight of the switch Ventilation Table 9 lists the ventilation requirements Table 8 Product Weight x330 10GTX Unpackaged 1 6 kg 3 53 lb Packaged 2 97 kg 6 55 lb Table 9 Ventilation Requ...

Страница 92: ...e switches Table 10 Environmental Specifications Operating Temperature Range 0 C to 50 C 32 F to 122 F Storage Temperature 25 C to 70 C 13 F to 158 F Operating Humidity 5 to 90 noncondensing Storage H...

Страница 93: ...consumption of the switch Input Voltage Table 12 lists the input voltage for the switch Note The input voltage current and frequency can be found on the rating label on the bottom panel of the switch...

Страница 94: ...latory Compliance Mark Common Criteria NIAP National Information Assurance Partnership European Economic Area EEA CE Conformit Europ enne WEEE Waste Electrical and Electronic Equipment RoHS EU 1025 86...

Страница 95: ...llation Guide 95 Mexico NOM Normas Oficiales Mexicanas North America FCC Class A Laser Safety EN 60825 1 CULUS Energy Star Russia EAC Eurasian Conformity United Kingdom UKCA UK Conformity Assessment T...

Страница 96: ...n signals for the copper ports Table 15 Pin Signals for Copper Ports Pin 10 100Mbps MDI 10 100Mbps MDI X 1 2 5 5 10Gbps 1 TX RX Bi directional pair A 2 TX RX Bi directional pair A 3 RX TX Bi direction...

Страница 97: ...yle Serial Console Port Pinouts Table 16 lists the pin signals of the RJ 45 style serial Console port Table 16 RJ 45 Style Serial Console Port Pin Signals Pin Signal 1 Unused 2 Unused 3 Transmit Data...

Страница 98: ...Appendix A Technical Specifications 98...

Отзывы: