4.2.2 Mode Commands ..…………………………………………………………………………….... 4-6
+FAE - Auto Answer Enable.................................................................................................... 4-6
+FTS - Transmit Silence.......................................................................................................... 4-7
+FRS - Receive Silence ......................................................................................................... 4-8
+FTM - Transmit Facsimile...................................................................................................... 4-9
+FRM - Receive Facsimile ...................................................................................….....…...... 4-10
+FTH - Transmit Data with HDLC Framing ....................................................................…..... 4-11
+FRH - Receive Data with HDLC Framing.........................................................…........…...... 4-12
4.2.3 Service Class 1 parameters ……………………...…........................................................... 4-13
+FAR - Adaptive Reception Control .........................................................…........................... 4-13
+FCL - Carrier Loss Timeout ................................................................….............................. 4-14
+
FDD - Double Escape Character Replacement ................................................................... 4-15
+
FIT - DTE Inactivity Timeout.................................................................…............................. 4-16
+FPR - Fixed DTE Rate............................................................................….…...................... 4-17
+FMI - Request Manufacturer Identification .............................................….…...................... 4-18
+FMM - Request Model Identification .......................................................….......................... 4-18
+FMR - Request Revision Identification ...................................................….......................... 4-18
+FLO - Flow Co……………………………………………………………………….……………. 4-19
4.3 Examples..............................…………………………………………………………………….. 4-19
Tables
Table 3-1. Result Codes........………………………………………………………………………… 3-15
Table 3-2. +MS Command Supported Rates............................................................................. 3-33
Table 3-3. V.8/V.8bis Example Commands/Responses for Originator and Answerer……........ 3-54
Table 3-4. AT#UD Last Call Status Report Format.................................................................... 3-61
Table 3-5. Call Setup Result Codes…………………………………………………………………. 3-62
Table 3-6. Multimedia Modes ..………………………………………………………………………. 3-62
Table 3-7. DTE-DCE modes ....………………………………………………………………………. 3-62
Table 3-8. V.34 INFO bit report..…………………………………………………………………….. 3-62
Table 3-9. gist Modulation Scheme Active from 3.7.2/V.58..............…...................................... 3-63
Table 3-10. error Control Active from 3.5.2/V.58........................................................................ 3-63
Table 3-11. compression Active from 3.2.2/V.58….................................................................... 3-63
Table 3-12. call Cleared codes from 3.6.4/V.58-1994 …........................................................... 3-64
Table 3-13. Completed Data Call, with Some Errors and Rate Retrain during the Call............. 3-65
Table 3-14. S-Parameter Summary …....................................................................................... 3-77
Table 3-15. Result Code Definition………………………………………………………………….. 3-86
Table 4-1. Fax Class 1 and Fax Class 1.0 Commands…........................................................... 4-2
Table 4-2. Fax Class 1 and Fax Class 1.0 Modulation Modes and Rates.................................. 4-9
Table 4-3. Inactivity Timer Start and Stop Events ….................................................................. 4-16
Table 4-4. Fax Class 1 Calling Sequence (Transmitting a Single Page).................................... 4-20
Table 4-5. Fax Class 1 Answering Sequence (Receiving a Single Page) ................................. 4-21
1 Introduction
1.1 Overview
This manual describes the host command and responses
.
The descriptions in this manual apply to all commands and parameters
.The commands and responses are implemented in host software
The .INF File contains exact
application unique information and default values.
1.1.1 Command Syntax
The fundamental DTE interface command syntax is described in Section 2.
1.1.2 Command Descriptions
These commands are grouped into the following categories:
Syntax and procedures Section 2
Data commands Section 3
Fax Class 1 and Fax Class 1.0 commands Section 4
Содержание Tornado 562 S II
Страница 1: ...Tornado 562 S II User Manual...