Chapter 7: Building the Trunk with Optional Stacking Ports
150
4
Verify that the switch hardware is operating correctly by entering the SHOW SYSTEM
ENVIRONMENT command. All components should have the status Ok.
awplus# show system environment
Environment Monitoring Status
Overall Status: Normal
Resource ID: 1 Name: AT-x550-18XSQ
ID Sensor (Units)
Reading
Low Limit
High Limit
Status
1
Fan: Fan 1 (RPM)
5980
4800
-
Ok
2
Voltage: 1.0V (Volts)
1.040
0.891
1.090
Ok
.
5
Display the version number of the AlliedWare Plus operating software on the switch
by entering the SHOW VERSION INSTALLED command. Write down the version
number in the worksheet in Table 19 on page 76. After viewing the version numbers
on all the switches, you will compare them to confirm they all have the same version.
Switches with different versions will have to be updated.
awplus# show version installed
Current software
----------------
Software version
:
value
Build date
:
value
Installed software
------------------
Build name
:
value
Build version
:
value
Build date
:
value
6
Move to the Global Configuration mode with the CONFIGURE TERMINAL command.
awplus# configure terminal
Enter configuration commands, one per line. End with CNTL/Z.
Step 7 enables the VCStack feature on the switch. You probably do not need to perform this
step because the feature is enabled by default. If the Switch ID LED is displaying “0”, perform
the step. Otherwise, go to step 8.
7
Activate VCStack on the switch with the STACK ENABLE command.
awplus(config)# stack enable
% Automatically enabling ‘stack virtual-mac’ to minimize disruption
form failovers.
% Please check that the new MAC 0000.cd37.0431 is unique within the
network.
% Save the config and restart the system for this change to take
effect.
Table 21. Configuring the Master Switch for Optional Stacking Ports - Part I (Continued)
Step
Description and Command
Содержание AT-x550-18XSPQm
Страница 8: ...Contents 8 ...
Страница 12: ...Tables 12 ...
Страница 16: ...Preface 16 ...
Страница 50: ...Chapter 1 Overview 50 ...
Страница 78: ...Chapter 2 Virtual Chassis Stacking 78 ...
Страница 90: ...Chapter 3 Beginning the Installation 90 ...
Страница 110: ...Chapter 4 Installing the Switch on a Table or in an Equipment Rack 110 ...
Страница 124: ...Chapter 5 Installing the Switch on a Wall 124 ...
Страница 190: ...Appendix A Technical Specifications 190 ...