Chapter 3: Port Configuration
60
notify the end node to stop transmitting for a specified period of
time. The possible values are:
Ignore
- This parameter indicates that the
All
setting does not
apply to the
Flow Control
field. In other words, each port is set
individually.
Enabled
- This parameter indicates that the port is permitted to
use flow control.
Disabled
- This parameter indicates that the port is not
permitted to use flow control.
EAP Pass
- This parameter reflects the current Extensible
Authentication Protocol (EAP) setting on the port. The possible
values are:
Ignore
- This parameter indicates that the
All
setting does not
apply to the
EAP Pass
field. In other words, each port is set
individually.
Enabled
- This parameter indicates that the port is able to send
and receive EAP packets.
Disabled
- This parameter indicates that the port is disabled
and is not able to send or receive EAP packets.
BPDU
- This parameter reflects the current BPDU setting on the
port.The possible values are:
Ignore
- This parameter indicates that the
All
setting does not
apply to the
BPDU
field. In other words, each port is set
individually.
Enabled
- This parameter indicates that the switch will pass
BPDU frames through the switch and broadcast them through
all other ports.
Disabled
- This parameter indicates that the switch will not pass
BPDU frames through the switch, With RSTP or STP enabled,
the switch will receive BPDU frames and process them
according to the spanning tree protocol.
3. From the main menu on the left side of the page, select
Save
Configuration to Flash
to permanently save your changes.
Содержание AT-GS950/16PS
Страница 12: ...Figures 12...
Страница 14: ...List of Tables 14...
Страница 18: ...Preface 18...
Страница 20: ...20...
Страница 52: ...Chapter 2 System Configuration 52...
Страница 54: ...54...
Страница 92: ...Chapter 5 Multiple Spanning Tree Protocol 92...
Страница 102: ...Chapter 6 Static Port Trunking 102...
Страница 118: ...Chapter 8 Port Mirroring 118...
Страница 140: ...Chapter 11 IGMP Snooping 140...
Страница 174: ...Chapter 14 GVRP 174...
Страница 186: ...Chapter 15 Quality of Service and Cost of Service 186...
Страница 188: ...188...
Страница 216: ...Chapter 17 SNMPv3 216...
Страница 244: ...Chapter 18 Access Control Configuration 244...
Страница 282: ...Chapter 21 Security 282...
Страница 288: ...Chapter 22 Power Over Ethernet PoE 288...
Страница 289: ...289 Chapter 23...
Страница 310: ...Chapter 24 LLDP 310...
Страница 322: ...322...
Страница 334: ...Chapter 26 Software Configuration Updates 334...
Страница 346: ...Chapter 28 Rebooting the AT GS950 16PS 346...
Страница 368: ...Appendix A MSTP Overview 368...
Страница 386: ...Appendix B AT GS950 16PS Default Parameters 386...