Chapter 1: Overview
22
AT-DC2552XS / L3 Rear Panel
The rear panel of the AT-DC2552XS / L3 is shown in Figure 2.
Figure 2. AT-DC2552XS / L3 Rear Panel View
Blank Covers - When the switch is shipped from the factory, four
blank covers are installed.
-
Two blank covers for the power supply slots (PS 1/PS 2)
-
Two blank covers for the two fan module slots (FAN 1/FAN 2)
Warning
To insure proper cooling and air flow within the chassis, the blank
covers should not be removed unless an AT-PWR06 power supply
module and the AT-FAN06 fan modules are installed in their place.
The power unit slots (PS 1/PS 2) are for the installation of the AT-
PWR06 power supply module. These slots are located on the far
right and far left sides of the chassis.
A second AT-PWR06 power supply module may be installed for
redundancy, but is not required for normal operation of the switch.
With a redundant power supply configuration, you can replace one
of the two power supply modules without turning off the primary
power supply. Each AT-PWR06 power supply module that is
installed in the chassis is hot-swappable. Refer to “Installing and
Replacing AT-PWR06 Power Supply Module” on page 60 for the
installation procedure.
Note
The AT-PWR06 power supply module is sold and packaged
separately from the AT-DC2552XS / L3 Enterprise Core Switch.
PS 1
FAN 1
FAN 2
PS 2
Blank
Covers
Slot
Slot
Slot
Slot
Fan 1
LED
Fan 2
LED
[Top of Chassis]
Содержание AT-DC2552XS
Страница 1: ...613 002097 Rev A AT DC2552XS L3 ENTERPRISE CORE SWITCH Installation Guide...
Страница 8: ...Figures 8...
Страница 10: ...Tables 10...
Страница 14: ...Preface 14...
Страница 34: ...Chapter 1 Overview 34...
Страница 44: ...Chapter 2 VCStack Overview 44...
Страница 86: ...Chapter 7 Managing the Switch 86...
Страница 90: ...Chapter 8 Troubleshooting 90...
Страница 96: ...Appendix A Technical Specifications 96...