TFTP
100
ATM Configuration
Description
FIELD IDENTIFIER and VALUEs
System ATM Address:
SYSTEM ATM ADDRESS =
“XXXXXXXX.........XXXXXXXX”
Allowable configuration data:
A maximum of forty (40) ASCII digits
Default Value:
NULL STRING
Exceptions:
For PVC systems only
System VPI
SYSTEM VPI = XXXX
Allowable configuration data:
A numeric value ranging from 0 - 255
Default Value:
0
Exceptions:
For PVC systems only
System ATM Framing
ATM FRAMING = SONET
Allowable configuration data:
SONET, SDH
Default Value:
SONET
Exceptions:
For ATM systems only
System ATM Clocking
ATM CLOCKING = INTERNAL
Allowable configuration data:
INTERNAL, EXTERNAL
Default Value:
INTERNAL
Exceptions:
For ATM systems only
System ATM UNI Signaling
ATM SIGNALING = UNI
Allowable configuration data:
3.0, 3.1
Default Value:
UNI 3.0
Exceptions:
For ATM systems only
System ATM Transmitter Idle
ATM TRANSMITTER IDLE = IDLE CELLS
Allowable configuration data:
IDLE CELLS, UNASIGNED CELLS
Default Value:
UNASIGNED CELLS
Exceptions: