To connect water service to a machine with hoses, use the follow-
ing procedure:
1.
Before installing hoses, flush the building’s water system at
the machine connection valves for at least two (2) minutes.
2.
Check filters in the machine’s inlet hoses for proper fit and
cleanliness before connecting.
3.
Hang hoses in a large loop; do not allow them to kink.
If additional hose lengths are needed or using hoses other than
those supplied by manufacturer, flexible hoses with screen filters
are required.
Specification
Model
Requirement
Water inlet connection size, in. BSP
8 kg / 20 lb. / 80 L - 35 kg / 80 lb. / 332 L
3/4
Water inlet connection size, in. BSP
52 kg / 115 lb. / 520 L
1
Recommended pressure, PSI [bar]
All
44-73 [3-5]
Inlet flow capacity per inlet, gal/min [l/
min.]
8 kg / 20 lb. / 80 L - 24 kg / 55 lb. / 240 L
5.28 [20]
Inlet flow capacity per inlet, gal/min at
15 PSI [l/min. at 1 bar]
28 kg / 70 lb. / 280 L - 35 kg / 80 lb. /
332 L
17.44 [66]
Inlet flow capacity per inlet, gal/min at
15 PSI [l/min. at 1 bar]
52 kg / 115 lb. / 520 L
48.34 [183]
Inlet flow capacity per inlet, gal/min at
116 PSI [l/min. at 8 bar]
18 kg / 40 lb. / 180 L - 35 kg / 80 lb. /
332 L)
49.66 [188]
Inlet flow capacity per inlet, gal/min at 116
PSI [l/min. at 8 bar]
52 kg / 115 lb. / 520 L
136.846 [518]
Table 10
Suitable air cushions (risers) should be installed in supply lines to
prevent “hammering.”
Alliance Laundry Systems, LLC ranges of front loading commer-
cial clothes washing machines have solenoid valves at the inlets.
The water supply to the washing machines is supplied with an
AB air gap between the soap tray and the drum. Minimum and
maximum working pressure 1 bar and 8 bar. The machines are
supplied with approved inlet hoses.
NOTE: This machine has a fluid category 5 backflow
prevention device built in between the soap tray and
drum.
To comply with WRAS (IRN R150), European standard EN1717,
an approved double check valve backflow prevention device with
the watermark is provided with the unit and must be fitted at the
point of connection(s) between the supply and the fitting.
NOTE: No more than two (2) water connection hoses
should be used on WRAS-approved models.
Figure 17
Water Reuse Connection
WARNING
Disconnect the machine power supply. When the
main switch is turned off, the inlet terminals of the
machine main switch are still under current.
W900
1.
Drill out the protective screens of the water reuse inlet using a
drill bit of .59 in. [15 mm] diameter. Refer to
Figure 18
.
IMPORTANT: Do not pierce the screens open. It
could lead to blockage of the water channel.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
31
Part No. D1634ENR4
Содержание WMA103E ARIES
Страница 2: ......