Installation on a steel base and floor
CHM2472N_SVG
7
6
5
4
3
2
1
2
2
1
1.
Nut
2.
Washer
3.
Spacing washer
4.
Anchor bolt
5.
Washer
6.
Concrete floor
7.
Bolt (supplied with steel base)
Figure 8
NOTE: The existing concrete floor must be at least 4.72
in. [120 mm] thick.
1.
Check that the machine is installed in a level and stable man-
ner in all its corners.
2.
If necessary, level the machine up by means of stainless or
galvanized spacing washers inserted between the machine
frame and the floor. Refer to
Figure 9
and
Figure 10
. The di-
mensions of the spacers must be the same as the dimension of
the machine frame in the place where the anchor bolts are lo-
cated (80 x 80 mm).
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT