20
36198
1.
Audio Signal “SIg”
This option allows the user to program when the
signals will sound and at what volume level.
There are four occasions where a signal may sound
during the washer operation. These four occasions are
listed below:
1. End of Cycle Signal
By default, the signal is turned off. If turned on, the
signal will sound for three seconds at the end of a
cycle at one of three programmable volume levels.
2. Keypad Depression Signal
By default, this signal is set at the lowest volume
level and will sound for .25 seconds. This signal
will sound each time a keypad is pressed at one of
the three programmable volume levels.
3. Coin Drop Signal
By default, this signal is off. If turned on, the signal
will sound for .25 seconds each time a coin is
entered at one of three programmable volume
levels.
4. Unbalance Signal
By default, this signal is off. If turned on, the signal
will sound on for three seconds and off for two
seconds for a total of one minute when the machine
is in the Spin cycle and becomes unbalanced. The
signal can be programmed at one of three
programmable volume levels.
How to Program the Audio Signal
1. Control must be in Special Mode. Refer to Section
VII.
2. While pressing and holding the PERM PRESS
keypad with one hand, press the COLD keypad
with the other hand. Programmable option number
one,
“SIg”
, will appear in the VFD. See Figure 5.
3. When
“SIg”
appears in the VFD, press the PERM
PRESS (enter) keypad. A three digit number will
appear in the VFD.
NOTE: The number appearing in the VFD is the
current number that was selected from Chart 1
located on the following page.
4. Locate the desired three digit number in the first
column of Chart 1 on the following page.
5. Press the DELICATES (+) or the COLD (-) keypad
to increase or decrease the current three digit
number until correct. See Figure 6.
For Example: A user might wish to have the signal
sound only when a keypad is pressed and at the lowest
level. Entering the three digit number 035 in step four
would turn off all the options except LOW VOLUME
and KEYPAD. In this instance, the signal would sound
at the lowest volume only when a keypad is pressed.
6. Press the PERM PRESS (enter) keypad when the
correct three digit number appears in the VFD. The
next option,
“HnC”
, will appear in the VFD.
NOTE: To program
“HnC”
(Hot Wash Number of
Coins), see option 2. To program other options,
refer to the appropriate section.
How to Exit Programming Feature
1. Be sure service door has been opened and closed.
Refer to Section VI.
2. Be sure the control shows a programmable option,
not a value.
3. While pressing and holding the PERM PRESS
keypad with one hand; press the COLD keypad
with the other hand. The control will revert back to
the “Ready” mode. See Figure 2.
Figure 5
WASH
RINSE
SOAK
SPIN
PRICE
TIME REMAINING
INSERT COINS
UNBALANCE
C105IE1A
Figure 6
NORMAL
HOT
DELICATES
COLD
PERM
PRESS
WARM
Press this pad (enter)
to choose a selected
value or option
Press this pad (+)
to scroll forward or
increase a value
Press this pad (-)
to scroll back or
decrease a value
C106IE1A
Содержание SWT421
Страница 2: ......
Страница 6: ...4 36198 Notes ...
Страница 8: ...6 36198 Notes ...
Страница 10: ...8 36198 Notes ...
Страница 12: ...10 36198 Notes ...
Страница 16: ...14 36198 Notes ...
Страница 18: ...16 36198 Notes ...
Страница 20: ...18 36198 Notes ...
Страница 62: ...60 36198 Notes ...
Страница 68: ...66 36198 Notes ...
Страница 70: ...68 36198 Notes ...
Страница 72: ...70 36198 Notes ...
Страница 74: ...72 36198 Notes ...