Error Codes
Display
Description
Cause/Corrective Action
EC11
No Card Reader
Initialization
Communication is valid, but there is no card reader initialization. Power down, power
up and try again.
EC18
No Communica-
tion
Card reader is initialized, communication lost. Power down, power up and try again. If
error persists, replace control or card reader.
EC19
No Card Reader
Communication
Communication failure. Power down, power up and try again. If error persists, replace
control or card reader.
Right most deci-
mal point Lit
Network Commu-
nication Error
Communication problem. Wait for 1.5 minutes for error to clear. If error doesn’t clear,
power-down and power-up the machine. If error persists, replace control or network
board.
Right most deci-
mal point Lit
Water Leak Detec-
tion Error or Slow
Drain Detection
Error
Water leak test has detected a water leak during a cycle or slow drain is detected in the
drain step of a running cycle. The decimal point will remain lit after the error display
has expired. Clear the decimal point by pressing the START keypad three times within
five seconds or by cycling the power to the machine.
Right most deci-
mal point blinking
Machine ID Error
Machine ID is no longer communicating with the control. Check Machine ID connec-
tion.
ALArn
Break-in Alarm
Error
Check the service door and coin vault switches.
oFF
Break-in Alarm
Shutdown Error
Check the service door and coin vault switches.
E FL
Fill Error
Fill level is not reached within 30 minutes (or other programmed length of time) in
any fill step.
Coin Error
Coin Error
Invalid coin pulse or inoperative coin sensor. Check coin drop area and remove ob-
structions. If error persists, tampering may have occured. Evaluate security proce-
dures.
E id
Board ID
Incorrect replacement control. Replace user control or output board with the correct
part.
E dS
Brownout/Voltage
Configuration
Unexpected supply voltage. Check the harness connections between the user control
and the output board. If the user control was replaced, set dip switch #1 to the same
seting as the previous control. If reworking the machine to use a different voltage sup-
ply, the dip switch #1 setting may need to be changed. If the dip switch #1 setting is
changed, power down, power up and try again.
E nr
Drive/Output
Board Not Ready
Hardware failure. Try cycling power to machine before replacing output board.
E bS
Drive/Output
Board Shorted
Hardware failure. Try cycling power to machine before replacing output board.
En
Machine ID Errors
Table continues...
Error Codes
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
83
Part No. 204370ENR1
Содержание SWNNC2HP115TQ01