Factory Test Cycle Quick Reference Chart
Display
Test Mode
Comments
U oP
or
U CL
Coin Vault Test
U oP
is displayed when coin vault
switch is open.
U CL
is displayed when
coin vault switch is closed.
0001
High Speed Spin
SPIN LED is lit and the control energizes
the high speed spin motor outputs.
0002
Hot Water Fill
Hot water fill valve is turned on.
0003
Cold Water Fill
Cold water fill valve is turned on.
0004
Pressure Sensor Fill
Hot and Cold water valves are turned on
until the tub fill level is reached. Test
cannot be advanced until the step is com-
plete.
0005
High Agitate
RINSE LED is lit and the control energi-
zes the high speed agitate motor outputs.
0006
Low Agitate
RINSE LED is lit and the control energi-
zes the low speed agitate motor outputs.
0007
Low Speed Spin
SPIN LED is lit and the control energizes
the low speed spin motor outputs.
0008
High Speed Spin
SPIN LED is lit and the control energizes
the high speed spin motor outputs.
0009
Warm Water Fill
Hot and Cold water valves are turned on.
0010
High Speed Spin
SPIN LED is lit and the control energizes
the high speed spin motor outputs.
0011
Auxilliary Output 1
The control energizes the Auxiliary Out-
put 1.
0012
Auxilliary Output 2
The control energizes the Auxiliary Out-
put 2.
0013
Auxilliary Output 3
The control energizes the Auxiliary Out-
put 3.
0014
Auxilliary Output 4
The control energizes the Auxiliary Out-
put 4.
Table 17
continues...
Testing Machine and Electronic Control Functions
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
80
Part No. 204370ENR1