44
70291301
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Electronic Control Troubleshooting
26. Will Not Start – Electric – Rotary Coin Drop (continued)
T076D
Correct wiring
between 2A of start
switch and COM of
lint panel switch.
Is there voltage at
2A of the start
switch?
Is there voltage at
terminal 7 of the
motor relay?
NO
YES
NO
YES
Correct wiring
between 7 of
motor relay and COM
of lint panel switch.
Refer to NO
MOTOR RUN
(run circuit).
Is there voltage to
H1-2 on TMR1
board?
STEP 1
Correct wiring
between
H1-2 and
output of
secondary
fuse.
With vend price
satisfied is there
voltage across N.C. &
COM of switch A?
NO
YES
YES
NO
Replace switch A.
Is there voltage across
the timer motor?
Is there voltage across
H1-6 & H1-8 of
TMR1?
Correct wiring
between timer
motor and COM on
switch A.
NO
YES
Correct wiring
between H1-6 and
COM on switch A.
Is there voltage across
H1-2 & H1-3 of
TMR1?
NO
YES
Is there voltage to N.O.
of door switch?
Replace TMR1.
YES
NO
Correct wiring
between N.O. of
door switch and
H1-3 of TMR1.
Continue at step 3
on previous page.
YES
NO
Does coinmeter timer
motor advance?
YES
NO
Replace timer
motor.
STEP 2
Note: Following tests
are conducted with
vend price satisfied.
Does the unit have
single phase or three
phase power supply?
Single phase
3 phase
Is there voltage at
terminal 14 of the
motor control relay?
Correct wiring to
terminal 14 of
motor control
relay.
Refer to NO
MOTOR RUN (Run
Circuit).
YES
NO
T076D