Electronic Control Troubleshooting
30. Will Not Start – Steam – Rotary Coin Drop (continued)
T063D
Correct wiring
between 2A of
start switch and COM
of lint panel switch.
Is there voltage at
2A of the start
switch?
Is there voltage at
terminal 7 of the
motor relay?
NO
YES
NO
YES
Correct wiring
between 7 of
motor relay and COM
of lint panel switch.
Refer to NO
MOTOR RUN
(run circuit).
Is there voltage to
H1-2 on TMR1
board?
COLUMN 1
Correct wiring
between
H1-2 and
output of
secondary
fuse.
With
vend price satisfied is
there voltage across N.C. &
COM of switch A?
NO
YES
YES
NO
Replace switch A.
Is there voltage across
the timer motor?
Is there voltage across
H1-6 & H1-8 of
TMR1?
Correct wiring
between timer motor
and COM on switch
A.
NO
YES
Correct wiring
between H1-6 and
COM on switch A.
Is there voltage across
H1-2 & H1-3 of
TMR1?
NO
YES
Is there voltage to N.O.
of door switch?
Replace TMR1.
YES
NO
Correct wiring
between N.O. of
door switch and
H1-3 of TMR1.
Continue at step 3
on previous page.
YES
NO
Does coinmeter timer
motor advance?
YES
NO
Replace timer
motor.
COLUMN 2
Note: Following tests
are conducted with
vend price satisfied.